_ _ _ _ _ _ _ _

l A

7590-01 I

NRC PUBLIC DOCUMENT ROOY l

NUCLEAR REGULATORY COMMISSION REGULATORY GUIDE Notice of Issuance and Availability The Nuclear Regulatory Coranission has issued a guide in its Regulatory Guide Series. This series has been developed to describe and make availabie to the public methods acceptable to the NRC staff of implementing specific parts of the Commission's regulations and, in some cases, to delineate techniques used by the staff in evaluating specific problems or postulated accidents and to provide guidance to applicants concerning certain of the information needed by the staff in its review of applications for permits and licenses.

Revision 1 of Regulatory Guide 1.130, " Service Limits and Loading Combinations for Class 1 Plate-and-Shell-Type Component Supports,"

delineates acceptable levels of service limits and appropriate combi-nations of loadings associated with normal operation, postulated accidents, and specified seismic events for the design of American Society of Mechanical Engineers Code Class 1 plate-and-shell-type component supports in light-water-cooled reactors.

Comments and suggestions in connection with (1) items for inclusion in guides currently being developed or (2) improvements in all published guides are encouraged at any time.

Conments should be sent to the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention:

Docketing and Service Branch.

7590-01 Regulatory guides are available for inspection at the Comission's Public Document Room, 1717 H Street NW., Washington, D.C.

Requests for single copies of the latest revision of issued guides (which may be reproduced) or for placement on an automatic distribution list for single copies of future guides in specific divisions should be made in writing to Jne U.S. Nuclear Regulatory Commission, Washington, D.C.

20555, Attention:

Director, Division of Technical Information and Document Control. Telephone requests cannot be accommodated.

Regula-tory guidas are not copyrighted, and Commission approval is not required to reproduce them.

(5 U.S.C. 552(a))

Dated at Rockville, Maryland this 4th day of October

1978, For the Nuclear Regulatory Commission.
?/$)}!nccr,4 Robert B. Minogue, Director Office of Standards Development P

-