4 j

s.

1 WQLF CREEK

~

NUCLEAR OPERATING CORPORATION Bart o. w.trw Preedens and CPwet ExecuePro Omcor January 14, 1988 VM 88-0009 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

20555 Mr. R. D. Martin, Regional Administrator U. S. Regulatory Conunission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011

Subject:

Docket No. 50-482:

Response to NRC Bulletin 87-02 Gentlemen:

The purpose of this letter is to transmit a response to NRC Compliance Bulletin No.

87-02,

' Fastener Testing To Determine Conformance With Applicable Materia). Specifications',

for Wolf Creek Generating Station (WCGS),

Unit No.l.

Bulletin 87-02 requested NRC licensees to 1) review their receipt inspection requirements and internal controls for fasteners and 2) independently determine, through testing, whether fasteners in stores at their facilities meet required mechanical and chemical specification require =ents.

The attachment to this letter provides the information i

requested by the bulletin.

If you have any questions concerning this matter, please contact me or j

Mr. O. L. Kaynard of my staff.

Very truly yours,

_._-2 a

Bart D. Withers i

President and Chief Executive Officer BDV/skw Attachment cc:

B. L. Bartlett (NRC) l P. W. O'Connor (NRC). 2 8801220445 880114 PDR ADOCK 05000482

  • EMC"*'* FEN N "

l l 0

DCD

]

1 STATE OF KANSAS

)

) SS COUNTY OP COPPEY

)

Bart D. Withers, of lawful age, being first duly sworn upon cath says that he is President and Chief Executive Officer of Wolf Creek Nuclear Operating Corporations that he has read the foregoing document and knows the content thereof; that he has executed that same for and on behalf of said Corporation with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.

By

,J Bart D. Withers President and Chief Executive Officer SUBSCRIBED and sworn to before me this /N day of

1986, t

ThaAa LcAmn v,.*

'.,'9 Notary Publio

~

a.,r. -

Expiration Date Y,/UO

'< f ;.c.

" +

/

e l

l I

1 i

Attachment to WM 88-0009 Page 1 of 45 January 14, 1988 Response To NRC Compliance Bulletin 87-02 I. Introduction on November 6,

1987, the Nuclear Regulatory Commission (NRC) issued NRC Compliance Bulletin 87-02,

' Fastener Testing To Determine Conformance With Applicable Material Specifications'.

This bulletin was issued as a result of a limited testing program initiated by the NRC due to a concern over the potential use of inferior fasteners which demonstrated the need to obtain-additional information on the adequacy of fasteners used in nuclear power plants.

The information requested concerns receipt inspection and internal control procedures for fasteners and the results of independent testing of fasteners.

The bulletin requested six specific actions to be taken which are individually answered in Section II of this response.

Section III of this response includes a sur=ary of the data taken during the fastener testing.

II. Resconse To Actions Recuested To Be Taken 1.

Describe a) the characteristics currently examined during receipt inspection of fasteners (i.e.,

head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance),

and b) internal controls utilized during storage and issuance from stock to assure the appropriate use of fasteners.

a)

Quality Control (QC) receiving activities are controlled by procedure QCP 7.1,

' Receipt Inspection'.

The purchase order identifies the applicable =aterial specification, i.e. ASTM or ASME designation.

During the receipt inspection process the QC Inspector reviews the applicable ASTM /ASHI specification to identify the marking criteria that is required.

Cther attributes routinely verified include correct size, grade, and thread pitch.

t Attachment to WM 88-0009 Page 2 of 45 January 14, 1988 Certified Material Test Reports are reviewed to verify chemical and physical test results are in compliance with the applicable e

material specification, and that they are traceable to the material received.

Any additional testing that is invoked by the purchase order (additional ASME Section III requirements, or supplemental testing) is reviewed for acceptance to the specified criteria.

Certificates of Conformance/ Compliance (C of C) are reviewed for traceability to the items received.

C of C's are reviewed to

. verify the correct certification statement is made as required by i

the purchase order.

ASME certificates of compliance are reviewed f

to ensure ecmpliance to the purchase order and ASME Section III requirements.

b)

Internal controls on materials utilized during storage and issuance from stock are described in procedures KP-2122,

' Material and l

Services Receipt', KP-2123, ' Material Storage and Handling', and KP-2124, ' Material Issue'.

l Material is stored in such a manner as to provide ready access to I

items for inspection and to minimize the necessity for excessive handling and the risk of damage.

Access control has been l

established in the warehouse facilities as a precaution against theft, vandalism, or misappropriation of materials.

A quarterly inspection of designated material storage areas is performed and documented to assure that the integrity of stored iter,s and containers is being maintained.

Some of the characteristics and conditions verified during this inspection are as follows:

Procedure conformance to assure adequacy of access control j

Signs of physical damage, corrosion or other deterioration of stored items.

l General housekeeping and cleanliness of storage areas.

Report any signs of use of food, drink, tobacco or other potentially contaminating i

material.

Adequacy of protection from fire, weather, movement of equipment and other factors which may result in damage to stored items.

All items are clearly marked and identified.

All protective covers and seals are in place and intact.

i

I i

Attachment to VM 88-0009 Page 3 of 45 January 14, 1988 l

l Identity and traceability of items are maintained in storage by use of WCHOC assigned material code numbers and lot numbers.

Lot n.imbers provide traceability between the items and the records for the items.

During storage, safety-related and non-safety-related items are divided and stored separately.

Description of items maintained in stcrage is provided via a warehouse database.

This database is utilized to select the correct item for a given plant application.

To control material during issuance from stock, the requestor must i

prepare a Requistion on Stores (ROS), which provides the material code number and other information to adequately describe the item (s) requested and its intended use.

This information includes the Plant Hodification Request, or Work Request number controlling the use or installation of the requested item.

The name and number of the equipment for which the requested item will be used is also I

included.

The requestor then obtains an approval signature and date from an authorized individual who is cognizant of where the

material, item, or part is to be used or installed.

A list of personnel authorized to approve an ROS is maintained by Purchasing i

and Material Services.

After the approval is

received, the l

requestor gives the ROS to Material Control for completion of the i

form and fulfillment of the requisition.

Once the material is issued from stock, the requisitioning organization is responsible for assuring appropriate use.

2.

Select a minimum sample of ten (10) non-safety related fasteners (studs,

bolts, and/or cap screws),

and ten (10) safety-related fasteners (studs, bolts, and/or cap screws) frcm current, in use, stock.

The sample is to be obtained by the licensee with the participation of an NRC inspector.

Fasteners procured to meet the following chemical and mechanical properties are of interest:

A-193 grades 37, 38, and B16: SAE J429 grades 5 and 8: A-449:

Types 1, 2, or 3: A-354 grades BB, BC, BD: A-490:

A-320 LTH:

A-307:

A.

563: or equivalent.

A sample of 10 safety-related fasteners and 10 non-safety-related

)

fasteners were selected on December 8, 1987.

These samples were taken with the participation of D. E. Norman, NRC Region IV inspector, and B. L. Bartlett, NRC Resident Inspector.

3.

For the selected sample of fasteners in item 2 include a sample of typical nuts that would be used with each fastener (one-for-one).

In particular, nuts purchased to the chemical and mechanical specifications of A-194 are of interest,

i Attachment to WM 88-0009 Page 4 of 45 January 14, 1988 At the same time the fastener samples were taken, a sample of nuts that would be used with each fastener was also taken.

TI 9 NRC inspectors also participated in this selection process.

4.

Chemical testing shall be performed on all samples.

Mechanical testing shall be performed on each safety-related fastener.

Hardness testing shall be performed on each nut and non-safety-related fastener.

All testing shall be performed by a laboratory which the licensee has qualified for this type of testing and appears on the licensee's approved vendor list.

Testing performed shall be done in accordance with the requirements of the fastener's specification,

grade, and class, and the test shall evaluate the ultimate tensile strength, hardness and chemical properties as required by the fastener's specification, grade, and class.

Each sample shall be tagged with the sample's identification (ID) number.

Prior to shipment, the samples were uniquely identified in accordance with existing WCGS procedures.

Samples were tagged with ID numbers WCGS-SP-039 thru WCGS-SP-078.

Samples were then taken to Metlab Testing Services Inc., in Tulsa,

Oklahoma, for testing which was performed during the week of December 14, 1987.

Metlab is a qualified labocatory for this type of testing and is on the Wolf Creek Nuclear Operating Corporation (WCNCC) qualified suppliers list.

The testing requirements of Bulletin 87-02 were conveyed to Metlab by a WCNCC purchase order and all testing was witnessed by a WCNOC Supplier Quality Representative.

5.

The results of all tests, together with supporting information, are to be reported to the NRC utilizing the format shown in Attachments 1 and 2 of this bulletin.

Include the names and addresses of suppliers and manufacturers of safety-related fasteners and, to the extent possible, of non-safety-related fasteners.

For any fastener found out of specification, provide an evaluation of the safety significance including censideration of the most limiting application.

Test results were provided by Metisb which meet the requirements of Bulletin 87-02.

Test results were reviewed by WCNOC's Quality 1

Engineering group and found to be in full compliance with specified 4

requirements.

Data sheets containing information requested by the bulletin are included in Section III of this response, i

I l

1

i 4

I j

i Attachment to WM 88-0009 Page 5 of 45 4

3 January 14, 1988 4

4

?

I 6.

Based on the results of the testing and review of current I

procedures,

describe any further actions being taken to assure that fasteners used in the plant meet the requisite specifications i

3 j

and requirements and that the operability of safety-related plant l

components is not affected.

t At this

time, no further action is warranted based on the acceptable testing results received from Metlab and the results of j

the review of current procedures by VCNOC and D.

E.

Norman of NRC i

Region IV.

I I

III.

5"===ry of Data From Tests Performed For Bulletin 87-02 l

l

}

As stated in Section II of this response, test results of samples sont to Metlab were reviewed by WCNOC and found to be in compliance with specified i

requirements.

Data sheets were then prepared containing the information l

required by the bulletin and are being included for NRC review.

The suggested data sheets in Bulletin 87-02 requested a description of the l

procurement level used to procure the subject fasteners.

Rather than adding it to each individual data sheet, the description of the procurement level i

used for the fasteners is generically discussed here.

i

{

)

Th's fasteners selected for sampling were designated for use in safety.

related applications and procured as safety-related/ Level IV.

As safety-f related/ Level IV. the following requirements apply:

i a.

Items are simple and standard in design and are typically 'off the j

shelf' items, i

i b.

Supplier is qualified and on the qualified suppliers list based on

}

WCNOC Supplier Quality approval of a 10 CFR 50 Appendix 3 Quality Program.

c.

10 CFR 21 provisions are invoked in the purchase order.

l j

d.

Item acceptance is based on supplier certification and receipt l

inspection.

l 3

1 4

e l

l

1 Attcchment to WM 88-0009 Pcgo 6 of 45 Fast m er W Data Sheet Sanple ID# WCGS-SP-039 Fastener

Description:

7/8" - UNC Nut Gr 6 Description of Sanple Stock Iocation: Whse 01 B3290603C Material Sp= 4fIcaticn as Documented by Licensee Records: SA194 Gr 6 Head Marking (Specificaticn and Manufacturer):

6CF Class / Procurement Imvels Safety-related/Procurment IArml W 4

General Plant Applicaticn (e.g., Pressure Boundary, Structural)

Pressure Boundry Supplier: HUB, Inskya.ated Manufacturers Cardinal Industrial Products 2146 Flintstone Drive 3873 West Oquendo Road Tucker, GA 30084 Ias Vegas, NV 89118 QA Requirenents Inposed on Vendcra Appendix B p W iais MECHANICAL ANALYSIS CHEMICAL ANALYSIS Hardness: C22, C23 C:

.14 Mn

.73 P

.023 i

l S:

.009 Sir

.33 Crt 11.50 4

i f

i Ni

.34 1

a Licensee Representativo:

OY

\\*S M ms B-l Quality Engineering l

.O

  • Attachment to WM 88-0009 Fastener Testing Data Sheet Page 7 of 45 Sanple ID# NCGS-SP-040 Fastener

Description:

1" UNC x 6 Stud B7 Description of Sanple Stock Iccaticn: Nhse 01 B3450503E Material Specification as Doctznanted by Licensee Records: SA-193 Gr B7

}kni Marking (Specificaticn and Manufacturer): C B7 K10 Class / Procurement Invol Safety-related/Procurenent Imvel IV General Plant Applicaticn (e.g., Pressure Ik:undaxy, Structural)

Pressure Boundry Supplier: HUB, Incorporated Manufacturer Cardinal Industrial Products 2146 Fl.intstcom Drivu 3873 West Oquendo Road Tucker, GA 30084 Ias Vegas, NV 89118 QA Requirunents Intesed on Vendor: Appendix B prvgma MECHANICAL ANALYSIS CHEMICAL ANALYSIS Ultimata Tensile:

143,401 C:

.40 Yield Strength:

131,455 Mn:

.83 Elongation:

21%

P

.012 j

Reduction of Area:

61.9%

S:

.014 Sin

.24 Cr 1.08 I

)b

.25 i

Licensee Papresentative l

OGr I-5 A9,

'1 hates B. D@ing Cuality th;ineer i

Attachment to Mt 88-0009 Page 8 of 45 Fastener M 1.ng Data Sheet i

Sanple ID# WCDS-SP-041 Fastener Descripticn 1" UNC Nut Gr 2H Description of Sanple Stock Iccaticn: Nhse 01 B3290301 1

Material Specificaticn as Documented by Licensee Records:

SA-194 Gr 2H i

Head Marking (Specificaticn and Mam1facturer):

D, Di, 2H, A8, C Class / Procurement IArvels Safety-related/Procuratant Imvel IV i

General Plant Application (e.g., Pressure Boundary, Structural) l Pressure W Supplier: HUB, Ir m p ated Manufacturers Cardinal Industrial Products 2146 Flintstcne Drive 3873 West Oquendo aced Tucker, GA 30084 Las Vegas, NV 89118 QA Requirements Inposed cn Vendor: Appendix B g @ ain MB3sANICAL ANALYSIS CHEMICAL ANALYSIS i

l Hardness: C25, C26 C:

.40 l

P:

.013 l

j S:

.016 1

I i

1 i

l i

l 1

j Idoensee Papresentatives i

i w

j ThCIMs B. CCO;Snl

{

00A11DY DUNN

i Attach:nent 2o kH 88-0009 Fastener Ttsting Data Sheet Page 9 of 45 Sanple IDt NCI;S-SP-042 Fastener

Description:

5/8 UNC x 6 Stud Gr 630 Deu::riptim of Sanple Stock Iccaticn: *se 01 B1810805A Material Specification as Documented by Licensee Records:

SA-564 Gr 630 Head Marking (Specification and Manufacturer): C 630 H3 Class /Procuranent Imvelt Safety-relatad/ Procurement Level IV General Plant Application (e.g., Pressure Bcendary, Structural)

Pressure Boundry Supplier: HUB, Incw.pa.ated Manufacturers Cardinal Industrial Products 2146 Flintstene Drive 3873 West Oquendo Road Tccker, GA 30084 Ias Vegas, NV 89118 L

s QA Requiratanta Inposed on Vendor: Apperdix B [u.Op.asi MECHANICAL MEYSIS CHDtICAL ANALYSIS Hardness: C38, C39 C:

.02 Ultimate a nsile:

176,981 Mn:

.73 Yield Strength:

167,224 P

.018 Elongation:

14%

S:

.008 Reducticn of Area:

57.5%

Sir

.39 i

Cri 15.76 Ni 4.05 Cut 3.26 Cb+'ra

.22 Licensee Representatives Signature @l@M NW Date 1-5*88

'Itaiss ~B. Dougan Quality EngirAeriTQ

i

'.o Mi 88-0009 Page 10 of 45 Sanple ID# NCGS-SP-043 1

l Fastener

Description:

5/8 IJNC Nut Gr 6 l

l Descripticn of Sanple Stock Incation: Nhse 01 B34440507C Material Wification as Wmtad by Ilcensee Records: SA-194 Gr 6 Head Marking (Specificatim and Manufacturer):

6CF Class /Procurunent Invol Safety-related/ Procurement Imvel IV I

General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundry 1

}

Supplier: HUB, Incorporated Manufacturer Cardinal Industrial Products 2146 Flintstcne Drive 3873 West Oquendo Road 4

Tucker, GA 30084 Ias Vegas, NV 89118 QA Raquirunents Igosed en Vendor: Appendix B p u p.ws MECHANICAL ANALYSIS CHDGCAL ANALYSIS Hardness: C26, C22 C:

.14 1

Mn:

.80 P:

.026 S:

.009 i

i Sie

.32

)

I Cr 11.50 I

Ilcm Representatives 2

)

Signature I

t (E

Data /-5 8B

'Ihcmas B. Opugan Quality Engineering

Attachment to kW 88-0009 Fastener Testing Data Sheet l

Page 11 of 45 Sanple ID# WCGS-SP-044 Fastener Descripticn 1/2 UNC x 3 Stud B8 Descripticn of Sanple Stock Incatim: Nhse 01 B28503040 Material Specificatim as Doctmented by Licensee Records: A193 B8 Head Marking (Specification and Manufacturer): HB B8 Class / Procurement Invel: Ncnsafety l

General Plant Applicaticn (e.g., Pressure Boundarf, Structural)

Pressure Boundry Supplier: Mid States Supply Manufacturers thknown Box 192 Wichita, KS 67201 i

e CA Requirments Inposed cn Vendor: None MECHANICAL ANALYSIS QEMICAL ANALYSIS Hardness:

B93, B94 C:

.06 W

.79 P:

.023 i

i S:

.012 i

i Sin

.68 f

l l

Cri 18.70 l

Ni 8.40 Licensee Representative P

hI bte I

% am vs.as

}

'Ihcznas B. fXnx;an i

Quality Engineering 4

I

i Attcchment to VM 88-0009 Fastanet Testing Data Muset Page 12 of 45 Sanple ID# NCGS-SP-045 Fastener Descripticn 1/2 UNC Nut Gr B8 Descripticn of Sanple Stock Iocaticn: mee 01 B28503040 Material Specification as Doctmented by Licensee Records: A-194 Gr B8 Head Marking (Specificatics and Manufacturer): (- -)

8 Class / Procurement Invol: Ncnsafety General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundry Si =, 11er: Mid States Supply Manufacturers thknown Box 192 Wichita, KS 67201 L

% Requirarents Inposed cn Vendcra Ncne MECHANICAL ANALYSIS OGNICAL ANALYSIS Hardness: B98, B96 C:

.08 Hn:

1.63 P

.025 S:

.016 Si

.29 Cr:

18.34 Nis 8.25 Licensee Representatives b

t,10" 15-88

'Ihcaras B. C$ugan

@ lity Engineering

Attachment to kH 88-0009 i

h W Data Sumt Page 13 of 45 l

Sample ID# NCES-SP-046 Fastener

Description:

1/2 UNC x 3 Stud Gr B7 Description of Sanple Stock location mse 01 B3130407E Material Specificatica as Documented by Licensee Records: A193 l

Head Marking (Specification and Manufacturer): T B7 i

Class /Procurunant Invols Nawafety

{

r General Plant Applicaticn (e.g., Pressure B:mndary, Structural) l Pressure Boundry i

a S W _ier: Unknown Manufacturer: Unknown 4

QA Requirurents Inposed m Verdor Ncne i

MECHANICAL MEYSIS CHEMICAL MU1YSIS Hardness: C28, C27 C:

.42 -

l 2:

.93 i

P:

.017 7

i l

S:

.022 l

1 Sie

.29 i

l Cri

.89 m

.25 J

l i

reONN Y:

i i

Signature

'N Date l

2.

1%rA

\\ % = PS mxan B. oinan Qualicy Engineering

.\\

)

)

s l

l Attachment to WM 88-0009 h hting Data M Page 14 of 45

)

Sanple ID6 NOGS-SP-047 Fastener

Description:

1/2 IJtC Nut Gr 2H i

l Description of Sanple Stock I.ocations mee 01 B3130407E Material W 4fication as wmtad by Licensaa Ramrds: A 194 Gr 2H i

Head Marking (Wficatica and Manufacturer):

2H - T or 7 Class / Procurement Invel: Nmsafety 4

1 General Plant Application (e.g., Pressure Boundary, Struc%ral)

Pressure Bound 7 i

Suppliers tW:nown Manufacturer: 1.hknown i

i 1

j

@ Requirements Inposed crt Vendor Ncne 1

l, 1

]

. M CAL ANALYSIS M CAL ANitNSIS I

Hardness: 'C29, C29 C:

.41

)

P

.015 l

1 S:

.020 i

i 1

Lteens e aepresentative i

Signature

(

Date j

. w l_OA t-5-M i

m: mas's, an W

l

. _ __ _ _, /

i Attoc'hment te VM 88-0009 Page 15 of 45 Sacple ID# NCGS-SP-048 Fastener Descripticn 1/2" IJNC x 3 Sttri Gr B7 Descriptien of Sanple Stock Iccaticm: Nhse 01 B3280707A

~

Material Specificatien as Documenta:t by Licensee Records: A 193-B7 Mead Marking (Specificatica and Manufacturer): JB7 QW Class / Procurement Imel Nonsafety l

General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundry i

Supplier: Kamen Supply Manufacturers thknown 623 E. Murdock Wichita, KS 67201 l

L CA Requirements Imposed cn Vendor: Ncne

)

MEDRNICAL ANALYSIS OGMICAL ANALYSIS

(

Mardness: C24, C24 C:

.40 I

191:

.80 P

.022 S:

.016 Sin

.25 Cr 1.07 Mot

.21 l

I Licensee Representative b

W 1-5 -AR Ratas B. Ocugan Quality Engi.wirq i

i

s

' Attachment to VH 88-0009 Fastanet W Data Sheet Page 16 of 45 Sanple ID# NCGS-SP-049 Fastener

Description:

1/2 UNC Nut Gr 2H Descriptim of Sanple Stock Iccaticn Nhse 01 B3280707C Material Wficaticn as Ibcumented by Licensee Records: A 194-2H Head Marking (Specification and Manufacturer): U-2H S-2H Class / Procurement IArml Nonsafety-related General Plant Jpplicaticn (e.g., Pressure Ibundary, Structural)

Pressure Boundry Supplier: Kamen Supply Manufacturer: Unknown 623 E. Murdock Wichita, KS 67201

@ Requi.rtments Inposed cn Verdor: Ncne MD34ANICAL ANALYSIS OGNICAL ANALYSIS Hardness: C28, C31 C:

.41 P

.019 S:

.015 Licensee Representatives b]![NEO l~b ~88

'Ihcznas B.

an Quality ineerinJ

c s

Attac'hment to WM 88-0009 Fastener W Data Sheet Page 17 of 45 Sanple ID# NOGS-SP-050 Fastener

Description:

5/8 IJNC x 6 Stud Gr B7 Descriptica of Sanple Stock Iccaticn Itse 01 B3200206C Material Specificaticm as Documented by IJ.censee Pecords: A 193 Gr B7 Head Marking ( W Hication and Manufacturer):

S B

B7 B7 Class /Procurament Imvel Ncasafety General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundry Suppliers tJnknown Manufacturer: I.inknown QA Requirinnents Inposed on Vendor: None MEEHANICAL ANALYSIS OGMICAL ANALYSIS Hardness: C25, C28 C:

.40 m

.86 P

.023 S:

.015 4

Sin

.28 Crt 1.05 N:

.19 Licensee Representatives h

_ uU,0c p5-88 Thcrras B. D:xxJa$

Quality Engineering

,s Attachment to WH 88-0009 Pastaner W Data Sheet Page 18 of 45 Sanple IN NOGS-SP-051 Fastanar

Description:

5/8 UNC Nut Gr 2H Description of Sanple Stock Location mse 01 B3200206D Material Specification as Dcx:umented by Licensee Records: A 194 Gr 2H Head Marking ( W 4ficaticn and Manufacturer):

2) F-2H
1) S-2H Class /Procurunent Imvel Nonsafety General Plant Application (e.g., Pressure Boundary, Stractural)

Pressure Boundry Supplier: Unknown Manufacturer: Unknown QA Requizamnts Inposed cm Vendor Ncne N VICAL ANALYSIS OEMICAL ANALYSIS Hardness: C25, C27 C:

.47 P

.013 S:

.021 Licensee Representative MGr 1 M W.cmas B. Dc4gan ouauty Engineering

t.

.s

'Attachmen2 to WM 88-0009 h W Data Sheet Page 19 of 45 Sanple ID6 NCGS-SP-052 f

Fastener

Description:

7/8" UNC x 5-1/4 Stud Gr B7 Eescription of Sanple Ctock Iccation: Nhse 01 B2820806L Material Specification as Docmented by Licensee Records: A 193 Gr B7 j

Head Marking (Sr='ification and Manufacturer): B7 V 'ID Class /Procurenant Imvel: Nonsafety General Plant Application (e.g., Pressure Boundary, Structural) i Pressure Boundry L

l

(

Supplier: Unkn'own Manufacturer: Unkno m 1

4 i

1 OA Requirements Intosed on Vendor Ncne f

!GOMICAL ANALYSIS CHDCICAL ANMXSIS Hardness: C27, C30 C:

.39

]

Mn:

.88 L

l l

Pt

.014 S:

.015 l

Sin

.27 Cr

.96

)

Mot

.24 Licensee Representatives I

b-DOf1 l-5-88 Signature Date num B. oma,0w Quality Engineering

o 0

Attachment to VM 88-0009 Fastenet W Data Subst Page 20 of 45 Scaple ID# NCGS-SP-053 6stenerDescripticn 7/8 Utc Gr 2H Nut Description of Sanple Stock Iccaticn: Nhse 01 B21300705H Material W4fication as Doctanented by Licensee Records: A 194 2H Head Marking (Specificaticn and Manufacturer):

2 en v 2HB DD 1 ea 2HB V DD Class / Procurement Imvel: Hensafety General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundry Suppliert, Unknown Manufacturers thknown

@ Requirenants Inposed en Vendor None HICHANICAL ANALYSIS Q W GCAL ANALYSIS Hardness: C26, C25 C

.42 P:

.014 S:

.018 i

l Licensee Rep 14Sentativet j

i bkhncb

'I'"'"

ws-sa M2nas B. DouganX Cuality Engineering j

- -..a

o O

Attachment to VM 88 0009 h W Data h Page 21 of 45 Sanple ID# WOGS-SP-054 Fastener

Description:

1 1/8-7 x 6 Gr 630 Descriptica of Sanple Stock to:aticn: hhse 01 01200230 Material Specification as Documented by Licensee Records: A564 Gr 630 Head Marking (Specificaticn and Manufacturer): H1100 H

Class /Procurunent Isvel: Ik:nsafety General Plant Applicaticn (e.g., Pressure Boundary, Stractural)

Pressure Boundry Supplier: Unknan Manufacturer: Unkron O\\ Requira mnts Irposed en Vendor 1Rne MIDGNICAL ANALYSIS OEMICAL MaLYSIS Hardness: C33, C37 C:

.04 Mn:

.47 P:

.015 S:

.016 Sin

.45 Cut 3.52 Ni 4.20 Cr 15.96 CWra

.33 Licensm Representative:

Signature N

Dato Onhd t-5 L:tR

'Ifxnas B. DCUgah

@lity Wirmin]

s Attachment to WM 88-0009 Fastanet* W Data Sheet Page 22 of 45 Sanple ID# NC%)S-SP-055 l

l Fastener Descripticn:

1 1/8-7 Nut Gr B6 1

Descriptica of Sanple Stock Iccation: Nhse 01 B2131003L 1

Material Specification as Documented by Licensee Records: A-194 Gr B6 Head Marking (Wificaticn and Manufacturer): J6B i

j class / Procurement Imvel: Nonsafety General Plant Application (e.g., Pressure Boundary, Structural) i Pressure Bourdry l

c

}

l J

Supplier: Unknown Manufacturers thknown i

I t

I QA Requirunants Inposed cn Vendor Ncne 1

h j

I l

. W RCAL ANALYSIS CFJMICAL ANALYSIS i

Hardness: C25, C26 C:

.11 4

j nu

.41 i

P:

.019 1

i S:

.011 I

Sie

.45

{

1

]

Cri 11.57 l

l i

1 j

i l

M MtaNWI i

Signature Data

_. -.. f\\ hot l BR l

W.cmas B. D:ugin 4

j Quality Engineering 4

s

' Attachment to VM 88-0009 Pastmer 'Ibsting Data Sheet Page 23 of 45 Sanple ID# N0GS-SP-056 Fastenar

Description:

3/8-16 int Gr A Description of Sarple Stock Iccation: Khse 01 B10021609L Material Specificatica as Documented by Licensee Records: A-563 Head Marking (Specificaticn and Manufacturer): None Class /Procurunent Invel: iknsafety General Plant Applicaticn (e.g., Pressure Boundary, Structural)

Structural

.e.affoldirg c

Supplier: TC Bolt /1Mt/Screa Manufacturers hn 1324 W.12th Kansas City, 10 64101 CA Rcquirunents Irposed cn Vender: Ik:ne IGrHANICAL MEYSIS CHDGCAL MEYSIS lurdness: B83, B86 C:

.04 P:

.018 S:

.018 1

i l

uccnsee Representauvo k @Mlf t-5 F8 Thcims B. IXxgah Mty Dgineering

~-

Attachment to WM 88-0009 Fastenst W Data Sheet i

Page 24 of 45 l

)

Sanple ID# NCGS-SP-057 Fastener Descripticn 3/8-16 Nut Gr A Descriptica of Sanple Stock Iocaticn: Muse 01 B10021609L i

l j

Material Specificatica as Documented by Licensee Records: A-563 Gr A i

j Head Marking (Wficatica and Manufacturer): Ncne 1

i

]

Class /Procurunant Imvel Hansafety i

j General Plant Application (e.g., Pressure Boundary, Structural)

Structural - Scaffolding Supplier BOSCO Fasterling Manufacturer Unknown 5801 Front St.

j Fansas City,)O 64120 i

i" i

QA Requirements T_W cn Vendcri Ncne i

i MIDRNICAL ANALYSIS QUNICAL ANALYSIS I

1 I

Hardness: B86, B84 C:

.08

]

1 P:

.024 l

1 j

S:

.015 i

i 3

I

}

i f

LlCenSee Representative 1

l Signature Date Akine 1 5-PA i

m

'Ih:rnas B. Dougap Quality @ m ing

Attachment to W 88-0009 h W Data Sheet Page 25 of 45 Sanple ID# NCES-SP-058 Fastener

Description:

3/8-16 x 21/2 Bolt Gr A Descriptica of Sanple Stock Iocation: Nhse 01 B10021610K Material Specificaticn as tecmented by Licensee Records: A 307 Head Mirking (Specificaticn and Manufacturer): lene - tb Mfg Marking Class /P:ocurament Invell Ncnsafety Gcceral Plant Application (e.g., Pressure Bcuntsry, Structural)

Structural - Scaffoldirq Supplier FC Bolt /that/ Screw Manufacturers hn 1324 W. 12th Kansas City,.T 64101 CA RequL'utents Inposed en Vendor lbne N'TICAL MEYSIS OiIMICAL NEYSIS Hardness: B93, B92 P:

.015 S:

.015 i

LicenSOe RepMSentatiVO:

d Y%

UDr.

\\- %- R 8

f. crus B. D::ugag Qual'.ty Engineering

=

Attachment to WM 88 0009 h W Data M Page 26 of 45

)

i Sanple IDG NCES-SP-059 i

Fastanee

Description:

5/8-11 x 2 Bolt Gr B l

Deacription of Sanple Stock Incation: *se 01 B3450403I i

]

Material W4 ficetien as Docununted by Idcensee Records: A 307 Gr B l

l I

Hand Marking (WI_fication and Manufacturer): C 1

j Class / Procurement Involt Safety-relatai/Procuzwunt Imvel IV

]

)

General Plant Jpplicatica (e.g., Pressure Boundary, Structural)

)

Structural i

Suppliers Cardinal Industrial Products Manufacturer:

Same 3873 Host overdo Road Ias Vegas, W 89118 l

QA Requirements Inposed cn Vendor: Appendix B r up.wu t

i i

MECHANICAL M RLYSIS QGNICE MRIXSIS

(

Hardness: B91.4, B93 P

.013 Ultimate musile: 78,407 S:

.0L1 i

r

)

I l

Licensee Representative:

i N

\\M

\\ 26

'IhcInas B. Dougan\\

l

)

j Quality Engirmering 4

O Attachment to W 88 0009 Fastener W Data Sheet Page 27 of 45 Saaple ID# WCGS-SP-060 Fastaner Descripticn 5/8-11 that Gr B Descriptien of Sanple Stock Incation: Nhse 01 B3450403I Material Specificaticn as Doctranted by Ideensee Records: A 563 Gr B Head.%srking (Specificaticn and Manufacturar): C 12 Class /Procurment Imvel Safety-relatad/Procuranent Imvel IV General Plant Applicaticn (e.g., Pressure Bcurdary, Structural)

Structural Suppliers Cardinal Industrial Products Manufacturer: Same 3873 West C4uendo Road Ian Vegas, IN 89118 QA Requirunents Inpceed cn Verdor Appendix B ju.@am MIDQ!TICAL MMINSIS DetICAL MmLYSIS Hardness: B95, B95 C:

.06 Pi

.015 S:

.016 9

l L

Licensm Representativei D

tuto Signature M_ m hluced l BR n u ns s. ccu;da Quality Engir.cering

).

s i

I I

Attachment to VH 88 0009 Page' 28 of 45 Festaner 'Desting Data !Ramat 1

1 1

Sseple ID# NOGS-SP-061 3

1 Fastanar

Description:

3/8-16 1 1/2 lblt Gr A t

i t

Descriptien of Sanple Stock Iccation: *se 01 B1820206D i

!{

Material Specification as D:xaznanted by Licensee Records: A 307 Gr A i

t i

j Hand Marking (Specif teatica and Manufacturer): Ncne No Mfg Marking i

t i

{

Class / Procurement Involt tensafety l

General Plant Application (e.g., Pressure Ik:undary, Structural)

{

i Structural I

I I

Suppliers thknown Manufacturer thknown j

1

{

CA Paquirements Inposed en vendor: N:ne 1

l

  • MID ONICAL ANALYSIS CM MICAL A!aLYSIS l

1 Hardness: B92, B93 P

.029 1

S

.017 l

  • 0nly mechanical test required fer bolts which are too short or ham insufficient i

thread length for full size testing in accordance with ASD( A 307, para. 4.1.

1 I

I i

)

i I

Licensee Papresentative:

, b, h me)

Date g_3. g g Signature

\\

t

'ltanas B. Doug,an Cuality Wir.eering

j.

t 1

L j

  • Attachment to WM 88-0009 ytetener Testing Data ' Bust i

Page 29 of 45 J

r

,s Sasple ID# NO3S-SP-062 t

.)

Fastener

Description:

1/4-20 x 2 1/4 Bolt Gr A I

I Description of Sanple Stock Incaticrit mee 01 51820206H

[

l Matmeial Specificaticri as hmtad by Licensee Records: A 307 Gr A i

Head Maddag (Wificatics and Manufacturer): A or M i

i class /Procurunent Invols Nonsafety

,i l

General Plant Application (e.g., Pressure Ik:undary, Structural) i j

j t

S c liers thknown Manufacturers thknown i

J i

l j

QA Requirements Inposed on Vendor: Ncne t

\\

MEO RNICAL ANALYSIS QGMICAL ANALYSIS l

t Hardness: B95, B99 P:

.015 l

4.

f 5:

.027 i

l 8

i 3

i i

I i

1 i

1, l

Licensee Repmsentative:

}

\\

R l

Signature esheOntud t-s-es Data 1

c a nas s. ceu a n l

Quality Engineering i

' Attachment to WM 88-0009 m W Data M Page 30 of 45 Smiple ID6 NCGS-SP-063 Fastener

Description:

1/4-20 Nut Gr A I

Description of Fairple Stock Iccatim: Whse 01 B1820206H I

k Material specificatim as Doctanented by Licensee Racords: A 563 l

t Head Marking (Specificaticn and Manufacturer): Hans Class / Procurement Imvel Hansafety General Plant 4 plication (e.g., Pressure Ibundary, titructural)

Structural l

l 9 - 11ers thknown Manufacturer: thknown

@ Requirunants Ly:-d on Vendor: Ncne I

MIDONICAL MRLYSIS OGMLCAL ANALYSIS Hardness: B91, B87 C:

.07 P:

.012 S:

.034 f

I L

l Licensee neprecentatives

~

l b

Mined I-S 8B

'Ihcras B. Dougah Quality Engineering i

f l

i

' Attachment to WM 88-0009 yhetener Testing Data Steet I

)

Page 31 of 45 l

i i

t semple ID6 NOGS-SP-064 l

l j

Pastener

Description:

7/8-9 x 2 3/4 Bolt Type 1 Description of souple Stock Iccations mee 01 R1431101 f

Material W4fication as Docamerited by Licensee Records: A-325 Tyga 1 t

Head Marking (specificatica and Manufacturer): A-325 C-N1 Clase/ Procurement Imvels Safety-related/Procuruent Imvel IV l

l General Plant Applicaticrt (e.g., Pressure acundary, Structural)

[

Structural I

)

e m ter: nun, Ir+.ted nanufacturers Cardinal Industrial Puxbets

[

2146 Flintstone Drive 3873 Most Oguendo Road i

Tucker, GA 30084 Ias Vegas, NV 89118 L

f S Requirements Ingesed at Vandcr: Appendix B prograra j

l MICHANICAL ANALYSIS QiltGCAL M N G.IS Hardness: C24, C24.5 C:

.30 f

Ultiente 1Waile:

137,229 m

.88 t

}

P

.015 I

S:

.016 i

1

)

)

u - r-3=mtauvet j

j signat a g g y Date l Ea8

{

w s. Doug*

i Quality Engineering 1

1

6

' Attachment to W 88-0009 Fastense W Data Sheet Page 32 of 43 Sanple ID# NCGS-SP-065 Fastener Daecription:

7/8-9 Nut Gr C 1

i Description of Sanple Stock Iccaticn

  • se 01 R1431101 i

Material Wification as Documented by Licensee Records: A 563 Gr C

)

Head Marking (WUication and Manufacturer): D IM 2H C A8 fl Class / Procurement Imvel Safety-relatal/ Procurement Imvel IV General Plant Applicaticn (e.g., Pressure Boundary, Structural)

I Structural I

Supplier: HUB, Incoqcrated Manufacturer Cardinal Industrial Products 2146 Flintstene Drive 3873 West Oquendo Road t

Tuckar, GA 30084 IAs Vegas, NV 89118 QA Requirements Inposed on Vendor: Appendix B W aru l

xsoanten matms oaxIcn marxstS

}

Hardness: C26, C28 C:

.37 P:

.017 1

1, S:

.014 i

i i

t t

I i

l LicenS40 RepISSentatives l

1 i

i Signature M \\ b M w )

cate i

1-5 BB i

l

'Ihcras B. Deu)pn

(

Quality Engineering I

t L

t

' Attachment to Mt 88 0009 restaner Testing Data Sheet Page 33 of 45 Sanple ID# NO3S-SP-066 Fastanar

Description:

3/4-10 x 4 Bolt Tygw 1 Description of Sanple Stock Iocation mse 01 B1810504K Material Specification as Doctanented by Licensee Records: A 325-Type 1 1

Head Marking (S=-ification and Manufacturer): A 325 !aarM t

Class / Procurement Invals Safety-related/Procurunant Imvel IV l

l General Plant Application (e.g, Pressure Ik:undary, Structural)

St:.wtural Supplier: HUB, In ws W eted Manufacturer Cardinal Industrial Products l

2146 Flintstone Drive 3873 West Oquendo Road l

Tucker, CA 30084 Ias Vegas, NV 89118 l

i l

l QA Requirunents Inposed cn Ven$ce: Appendix B g %s-u MIDENICAL ANAINSIS OGNICAL MRLYSIS Hardness: C26.2, C29.5 C:

.31 Ultimate 'amsile:

152,665 Mn:

.79 P:

.016 S:

.014 Licensee Representative:

D@C l-5-89 mras87ceog.

Quality Ehgineering

r.

s I

i i

l j

' Attachment to W 48 0009 Pastensu* W Data hast i

l-Page 34 of 45 1

l Sample ID# NCGS-SP-067

}

[

j Pastanar Descripticrt:

3/4-10 Nut Gr 2H i

I l

Descripticut of Senple Stock Incaticm mee 01 31810504K

[

}

i j

Material Wfication as Decmanted by Licensee Records: A 194-2H i

i Head Marking (Wification and Marmafacturer):

2H D !31 1 C

[

5 l

i Class /Procurament Imel Safety-related/Procurwent Imel IV l

l I

j Geraral Plant Application (e.g., Pressure Boundary, Structural) l t

j Pressure Boundary

}

1 r

9 r lier: HLB, Irmy. tad Manufacturers Cardinal Industrial Products l

2146 Flintstcme Drive 3873 Most Oquendo Road i

j Tucker, GA 30084 Ias Vegas, NV 89118 l

a naquirments Inve.ed on venacr appendix a program t

I t

NECHANICAL ANALYSIS QIDGCAL ANMXSIS i

1 Hardness: C26, C27 C:

.40 I

i P

.023 i

i 4

S:

.015 i

i I

r 1

)

i

)

i Licensee Representative Signature 4

Date 1

uccd I-S AS

'Ihcznas B. Ocugap l

Quality Engineering

!___.-_.____~..--_-___-.___-,

- I

o e

Att:ch:nent to VM 88-0009 Fastener W Data Sheet Page 35 of 45 Sanple ID# NO3S-SP-068 Fastener Descripticn 1" - 9 x 4 Bolt Type 1 Deecriptien of Sanple Stock Iocation: hhse 01 B160807L Material Specificaticn as Documented by Licensee Records: A 325 Head Markirq (Specification and Manufacturer):

d A325 Class /Procurment Invel: tensafety Gmeral Plant Applicaticn (e.g., Pressure Dxnity, Et.ructural)

Structural Supplier: Unknckn Manufacturer: Unkn:En Or\\ Requirments Invesed en verdor: inne NNICAL MEYSIS DE{ICAL M:ALYSIS Hardness: C25, C25 C:

.33 Mn: '. 30 i

Pi

.014 S:

.010 Licenseo Representatives i

b iCun(3 l 88 2xas B. ChxJag Qwility L'ngineerity

1.

s d

t 1

I l

Attachment to VH 84-0009 h W Data test l

Page 36 of 45 i

i I

I sample ID# WCGB-SP-069

{

l I

j Postener

Description:

1 - 9 mit or c f

1 r

1 Description of sample stock Incations mee 01 52131004D I

J

(

l l

Material W ification as Docanntad by I.icensee Records: A-563 1

t j

Head Marking (W4ficaticn and Manufactmar):

P d 2N Class /Procuruent Imvel Monsafety

(

General Plant Agplication (e.g., Pressure Boundary, struc'tural)

Structural l

i 9 = 11er: Unknown Manufacturers tH mcwn

[

t i

j

@ Requizuments Imposed on Vendor: Mcme I

f MBCHANICAL ANhIXSIS QtpCCAL ANh!NSIS l

4 l

Hardness: 399, B99 C:

.44 I

i i

l P

.014 i

j 5:

.019 I

i l

i I

l 1

1 1

1 I

i i

i i

l Licensee Representatives i

Y _fDf3T

\\.5 RB Thcnas 3.'0 9 l

oauty rngineering j

i l

1

o 4

l

(

' Attacreent to VM 88-0009 h

Data Sheet Page 37 of 43 Sanple ID# ICE-SP-070 b

Fastaner Descriptim:

l' - 8 x 2 1/2 Bolt l

Description of Sanple Stock Iccation: mee 01 B1910602 f

l Material Specificatim as Documented by Licensee Records: A-490 Head Marking (Wification and Manufacturer): A 490 m i

l Class / Procurement Imvel: Safety-rslated/ Procurement Iavel IV l

General Plant Application (e.g., Pressure Boundary, Structural) l Structural t

L Sup50,16es A&G Engineering Co.

Manufacturer Texas Bolt Co.

4640 E. Impalan Ave.

P. O. Ikx 1211 Anaheim, CA 92807

}k:ustm, TX 77251-1211 QA Requirements InTeeed m Vendor: Aggerriix B Pcw I

  • MIGANICAL ANMXSIS CHDUCAL ANMNSIS Hardness: C36, C34.5 C

.43 i

  • Bolts too short for tension testing P

.018 shall cnly have hardness testing as required by para. 5.1 of ASM A-490.

S:

.014 i

l I

Licensee Representatives M vnfD l-5 PR

'1hcznas B. Icugan\\

Cuality EngirAering l

~

s Attachment to W do 0009 mqmm Page 34 of 45 semple ID# N0Gs-sP-071 Pastaner

Description:

1" - 8 Itat Ge 2N Descriptim of seaple Stock Ications mee 01 R1430601 Material Fificatim as Documented by Licensen Records: A-194 Gr M Head Marking (specification and Manufacturer):

2 "A"

class / Procurement Level Safety-relatad/ Procurement Imvel IV General Plant Applicatim (e.g., Pressure Boundary, structural) structurel 9 - 11ers cardinal fedustrial Products Manufacturer Sane 3873 West Oguendo Mond Ias Vegas, NV 89118 ts Inyceed m Vander: Appendix 3 Program MB:lMANICAL ANEYSIS O R GCAL AMkIXSIS Hardness: C27, C25 C:

.40 P

.015 5:

.014 Licensee Representatives i

't-

%ab,'h i

1. s. m Wanas 8. Dou;/mn omz -~

-,, ~,

---nc---,, -., ---, _, -, - -,, - - - -.,, - -, -.-

nn__,

,_-,,-,_.-,.n-_.,s y.

--_,_.-..,--,-n

,,m

,-y

,n

o

~

Attachment to VM 88 0009 yastener W Data 9teet i

Page 39 of 45 i

Sairple 106 WCG3-SP-072 c

Fastener

Description:

5/16 - 18 x 1 1/2 M CS i

Descriptitut of Sanple Stock Icontion mee 01 514509060 l

J l

Material Specification as Doctanented by Licensee Records: A 449 l

t

}

I I

Head Markin,7 (W1fication and Manufacturer): I2 i

yg i

i class /Procursunant Imel Safety-relatal/Procarument Imvel IV

{

l t

i General Plant Applicaticrt (e.g., Pressure Ikaundary, Structural)

General Stock i

i f

9 g liers Cardi.nal Industrial Products Manufacturer: Same 3873 West ocpando Road

-l l

Las Vegas, NV 89118 l

j m Requirments LW cn vendar: Appendix's Pa w e

{

MICHMTICAL AELYSIS OGNICAL AELYSIS Hardness: C25.5, C26 C:

.41 l

i Ultimate h wile:

131,679 m:

1.53 i

Pi

.017 i

J S:

.018 1

1 i

i i

i

)

LiCWuee RepITtsentatiVB:

i I

tune 15-88

~

i hs B. I)cu;ah I

Quality Engineering 1

_ _ _ _ _ _ _. _ ~ _

Attachment to VM 88-0009 y m W Data h Page 40 of 45 Sanple ID9 WCGS-SP-073 Fastaner

Description:

5/16 - 18 Nut Gr A Descriptim of Sample Stock Iccatico Ese 01 B1291303P Material W ification as Decuented by Licensee Reconia: A 563 Gr A Head Nazking (Wtficatim and Manufacturer): It:ine i

class /Procurunent Imel Safety-relatai/ Procurement Invel IV General Plant 4 plication (e.g., Pressure Boundary, Structural)

General Balting Suppliers Cardinal Industrial Products Manufacturer: Samm 3873 West oquerdo Road Ias Vegas, NV ' 89118 a

% Papirments Inposed en Vendor 4pndix B Prvv =e MID WTICAL ANALYSIS CHIMICAL MELYSIS Hardness: 581, B82 C:

.03 l

P:

.019 S:

.019 Licensee Representative Signature Date

$l}(1,

'Ih: ras B. Ceu; pan 5 * %

Cuality Engineering

d o

Attachment to WH 48-0009 yhtener W Dah h Page 41 of 43 Sangle ID# N0GS-SP-074 Fastaner

Description:

1/2 - 13 x 11/2 Pets Descripticn of Sample Stock Iccation mee 01 31450905L Material Specification as Documented hy Licensee Records: A 449 Hand Marking (WHicatica and Manufacturse): RS )s Class /Procurunant Invol:

Safety-related/Procuressant Imval IV General Plant Agp11 cation (e.g., Pressure Boundary, Structural) f General kalting Stock i

  • = lier Cardinal Industrial Products Manufacturer: Sarne 3873 West Cquando Road Ian Vegas, NV 89118 t

@ RequLuts Invesed en Verdor: Aspndix B hw MBOWICAL AHMNSIS QGNICAL ANP@rSIS Hardness: C26, C27.5 C:

.32 I

i Ultimata TW alle:

139,817 m:

.72 l

7:

.017 i

f S

.019 i

Licer.see aspamentatin:

Ytf

\\*b*

Th:anas B. cco;&n W lity Engineering j

j

a <; 9

' At achment to W 88-0009 Fastener Testing Data Sheet Page 42 of 45 Sanple ID# NCGS-SP-075 Fastener

Description:

1/2 - 13 Nut Gr A Description of Sanple Stock Iccaticn: Whse 01 B1291305D Material Specification as M = nted by Licensee Records: A 563-86 Gr A Head Marking (Spr.ification and Manufacturer): None class /Procurment Iavel Safety-related/Procurment Imvel IV Ger1eral Plant Applicaticn (e.g., Pressure Boundary, Structural)

General Bolting Stock Suppliers Cardinal Industrial Products Manufacturer:

Same 3873 West Oquendo Road Ias Vegas, NV 89118 i

QA Requiremrnts Inicsed on Vendor Appendix B Progme

@CHANICAL ANAINSIS GEMICAL ANAINSIS Hardness: B89, B90 C:

.05 P

.021 S:

.012 i

1 i

Licensee Representative Signature Date OLUQf

\\~$-%

2Ecuras B. Dougan Quality Engineerin[g

'w o 9 Attachment to WM 88-0009 Pastrmer Testing Data Sheet Page 43 of 45 Sanple ID# WCES-SP-076 Fastener

Description:

3/4" UNC x 6 Stud B7 Descripticn of Sanple Stock Iocaticn: Nhse 01 B3450502A Material Specificaticn as Documented by Licensee Records: SA-193 GR B7 Head Marking (Specificatico and Manufacturer): C B7 Y 14 Class / Procurement Imvels Safety-related/ Procurement Inval IV Ge e l Plant Applicaticm (e.g., Pressure Boundary, Structural)

Pressure Bourdary Supplier: HUB, Ineu. p ted Manufacturer Cta.tiinal Industrial Products 2146 Flintstcne Drive 3873 West Oquendo Road e

Tucker, GA 30084 Ias Vegas, NV 89118 l

1 QA Requizments I:T(.csed en Vendor: Appendix B P1Op.aie

)

MEDIANICAL ANALYSIS CHDETCAL ANALYSIS Yield Strength:

136,797 C:

.40 Ultimate 'nmailot 144,910 Mn

.79 Elengation:

17%

P:

.012 Reductica of Area:

61.2%

S:

.018 Sit

.29 Cr 1.00 Mot

.20 Licensee Representative e ib Signature Date Jh%Kt tnd

\\-5-88 Thcneh B. Dougap Quality Engineering l

J

D o ap u Attachm,nt to WM 88-0009 Fastener 'liurting Data Sheet Page 44 of 45 Sample ID# NCGS-SP-077 Fastener

Description:

Nut - 3/4" UNC Gr 2H-Description of Sample Stock In::ation: Whse 01 B1290802L Material Specification as W= anted by Licensee Records: SA 194 GR 2H Head Marking (Specification and Manufacturer): C 2H W-1 Class /Procurment Isvels Safety-related/Procurment I.sval IV General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: HUB, Incc.u. Meted Manufacturers Cardinal Industrial Products 2146 Flintstene Drive 3873 West Oquendo Road Tucker, GA 30084 Ias Vegas, NV 89118 QA Requirments Lgosed on Vendor: Appendix B Prsp.aui MECHANICAL ANALYSIS CHEMICAL ANALYSIS Hardness: C27, C26 C:

.40 P:

.028 S:

.015 Licensee Representative:

Signature Date

) Al@(~

I A R

'Ihcnes B. Dotga4 Quality Engineering

bas Attachment to WH 88-0009 Page 45 cf 45 Fastener Testing Data Sheet Su ple ID# WOGS-SP-078 Fastener

Description:

7/8" UNC x 6 Stud Gr 630 Descripticn of Sanple Stock Iocaticn: Whse 01 B3480301I Material Specificaticm as Documented by Idcensee Records: SA 564 GR 630 Head Marking (Specificaticn and Manufacturer): C 630 H1 Class / Procurement Invel:

Safety-related/Procurment Isvel IV General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: HUB, Incorporated Manufacturers Cardinal Industrial Products 2146 Flintstone Drive 3873 West Oquendo Road Tucker, GA 30084 Ias Vegas, NV 89118 QA Requirments Imposed on Vendor: Appendix B Prean MECHANICAL MEYSIS CHDiICAL MEYSIS Hardness: C34, C35 C:

.01 Yield Strength:

161,914 Mn:

.80 Ulthnate Tensile:

162,831 P

.018 Elongation:

17%

S:

.007 Reduction of Area:

62.6%

Sin

.30 l

Impact Test:

75, 100, 71 Cut 3.11 Ni 3.66 Cr 15.97 Cb+ Tai

.20 Ideensee Representative Signature x

w Curvd Cate \\-5 88

~

ThcmasB.'Dougag Quality mgineerin]