Forwards SE Accepting Proposed P-T Limits for Heatup, Cooldown,Inservice Leak & Hydrostatic Testing & Core Criticality Acceptable to 12 Efpy.Salp Input Also Encl
ML20147H413
Person / Time
Site: River Bend Entergy icon.png
Issue date: 03/31/1997
From: Wichman K
NRC (Affiliation Not Assigned)
To: Beckner W
NRC (Affiliation Not Assigned)
Shared Package
ML20147H417 List:
References
TAC-M97834, NUDOCS 9704030109
Download: ML20147H413 (1)


Text

< ~

March 31, 1997 MEMORANDUM TO: William D.'Beckner, Project Director Project Directorate IV-1 Division of Reactor Projects, III & IV FROM: Keith R. Wichman. Section Chief Material Integrity Section Materials and Chemical Engineering Branch Division of Engineering

SUBJECT:

RIVER BEND STATION: PRESSURE TEMPERATURE LIMITS EVALUATION License: Entergy Operations Incorporated TAC No.. M97834 Review Status: Complete By-letter dated January 10. 1997, the licensee submitted changes related to the pressure-temperature (P-T) limits in the River Bend Station Technical' Specifications (TS). The licensee revised the P-T. limits to provide.new limits that are valid to 12 effective full power years (EFPY).

Based on our evaluation of the submittal we conclude that the proposed P-T limits for heatup, cooldown, inservice leak and hydrostatic testing'and' core criticality are acceptable to 12 EFPY, and may be ' incorporated in the River Bend Station TS. 4 Our evaluation is submitted as Attachment l' and our'SALP input is submitted.as~

Attachment 2. This completes our efforts for TAC NO. N97834. ,, ,, 4; z

Docket No.: 50-458 ,

Attachment:

As stated cc: D. Wigginton ,

J. Strosnider CONTACT: A.D. Lee NRR -

415-2735 DIS"RIBUTION-

  • MeilMiMD" EMCB RF/PF PUBLIC ,

JStrosnider MMayfield G:\ LEE \RIVERBND.P T *See Previous Concurrence Toreceiveacopyofthisdocument.IndicateintheboxC-Copyw[dattachment/enclosureE-Copy with attachment / enclosure N - No copy /

l OFFICE DE:EMCB* DE:EMCB C DEIEdik O h NAME Alee BElliot fa% K M an DATE 3/28/97 331/97 3SF97 I

!. l 030009704030109 970331

! PDR ADOCK 05000458 l P PDR