Text
l
[
March 25, 1997 Federal Energy Regulatory Commission p#, gg 3$
Division of Dam Safety and Inspections Atlanta Regional Office i
Attn: Mr. John C. Lyon, Jr., P.E.
3125 Presidential Parkway Atlanta, GA 30340-3700 i
SUBJECT:
SERVICE WATER RESERVOIR DAM, NORTH ANNA POWER STATION, MINERAL, VIRGINIA
Dear Mr. Lyon:
Enclosed herein are settlement data for the structures at the referenced site. The information was provided by Mr. Michael P. Whalen of Virginia Power
]
in accordance with your request.
If you have any questions regarding the submittal, please call me at 301-415-6704.
Sincerely, (Original signed by)
Daniel S. Rom, P.E.
Geotechnical Engineer Uranium Recovery Branch Division of Waste Management Office of Nuclear Material Safety and Safeguards
Enclosure:
As stated o (01 DISTRIBUTION:
FILE' CENTER PUBLIC NMSS r/f URB r/f I
DOCUMENT NAME:S:\\DSR\\N-ANNA.00C
/
0FC URB NAME DROM M DATE 3A* /97
/ /97 0FF'CIAL RECORD COPY pe -- oseg ggHL
pm l
\\
MEMORANDUM VIRGINIA POWER NORTH CAROLINA POWER i
To:
Daniel Rom North Anna Power Station f
i From: M. P. Whalen March 12,1997 Settlement Data Service Water Reservoir Structures The settlement data information requested during the NRC/FERC Inspection Exit Meeting on Wednesday, February 12,1997, is enclosed if you need any other information or if I can be of any further assistance please let me know.
3
/
Michael P. Whalen Licensing (540)894-2572 4
j d
l 4
i i
~.
i i
i SETTLEMENT OF STRUCTURES AT SERVICE WATER RESERVOIR DIKE 1991 through 1996 i
Poir.t No. 7 Point No. 8 -.
Point No. 9 Loc: tion:
NE comer of SWPH Location:
SE comer of SWPH Location:
SW comer of SWPH -
Date Change from Date Change from Date Change from Baseline in Ft.
Baseline in Ft.
Baseline in Ft.
3-91
-0.135 3-91
-0.153 3-91
-0.227 10-91
-0.138 10-91
-0.160 10-91
-0.237 3-92
-0.141 3-92
-0.160 3-92
-0.223 1
10-92
-0.138 10-92
-0.155 10-92
-0.237 3-93
-0.145 3-93
-0.155 3-93
-0.237 10-93
-0.146 10-93
-0.162 10-93
-0.244 3-94
-0.153 3-94
-0.163 3-94
-0.245 l
10-94
-0.149 10-94
-0.164 10-94
-0.246 i
[
3-95
-0.152 3-95
-0.162 3-95
-0.245 10-95
-0.148 10-95
-0.163 10-95
-0.247 3-96
-0.152 3-96
-0.161 3-96
-0.244 s
10-96
-0.152 10-96
-0.166 1u-96
-0.251 Paint No.10 Point No. 25 Point No. 26 Location:
NW comer of SWPH Location:
NE comerof SWVH Location:
SE corner of SWVH Date Change from Date Change from Date Change from Baseline in Ft.
Baseline in Ft.
Baseline in Ft.
3-91
-0.163 3-91
-0.010 3-91
-0.005 10-91
-0.170 10-91
-0.013 10-91
-0.005 3-92
-0.173 3-92
-0.013 3-92
-0.005 10-92
-0.170 10-92
-0.013 10-92
-0.005 3-93
-0.177 3-93
-0.018 3-93
-0.009 10-93
-0.178 10-93
-0.015 10-93
-0.008 3-94
-0.185 3-94
-0.019 3-94
-0.008 4
3-95
-0.185 3-95
-0.019 3-95
-0.008 i
10-94
-0.182 10-94
-0019 10-94
-0.012 10-95
-0.182 10-95
-0.016 10-95
-0.009
?
3-96
-0.187 d-96
-0.020 3-96
-0.010 i
10-96
-0.187 10-96
-0.021
% 96
-0.013 Point No. 27 Point No. 28 Location:
. SW comer of SWVH Location:
tM/ corner of SWVH Date -
Change from
"~~
Date Change from Baseline in FL Baseline in Ft.
3-91
-0.005 3-91
-0.015 10-91
-0.011 10-91
-0.015 3 -0.008 3-92
-0.018 10-92
-0.008 10-92
-0.018 3-93
-0.011 3-93
-0.019 10-93
-0.012 10 93
-0.018 3-94
-0.011 3 94
-0.021 10-94
-0.016 10-94
-0.022 3-95
-0.012 3 95
-0.021 10-95
-0.012 10-95
-0.019 3-96
-0.014 3-96
-0.022 10 96
-0.016 10-96,,
-0.023
1
- 7
~
_1 9
m 6
9 l'
)
H i
5 9
P e
s W
r S
I' ae
(
Y m
7 4n 9
M i
S e
f i:
I' m
m o
iT tn 3
e 9
me 1'
ltt e
2 S
9
- 1 1
9 0
0 0
0 0
0 0
2 3
4 5
1 0
0 0
0 0
0 EO C.
Cq)E0 %Oy
)
l
Settlement of SM-8 (SWPH,'l 0.00 "g
-0.10
]
e LL t.-
- i_ re:
.E
-0.20
+*
C D
:
E
-0.30 m
'(j)
-0.40
-0.50 i-Ej 91 92 93 94 95 96 97 Time in Years 4
T
7 9
~
6
__ 9
,l i
)H 5
9 P
_r s
W r
a S
e
(
Y 9
4 9n M
=
i S
e m
fo
=
i T
tn 3
e
=
9 me l
tte
=
2 S
=s 9
,L
=
1 9
0 0
0 0
0 0
0 1
2 3
4 5
0 0
0 0
0 0
m
$ OLE.y EG3&G)(
)3 f
L
Settlement of SM-10 (SWPH) 0.00
~
-0.10 (D
q)
LL.
m_
=
a I
'i
~
~ ~ * '
Z C
-0.20
~c E
-o.30
=
(D (D
CO
-0.40
-0.50 l
92 93 94 95 96 97 91 "
~~ime in Years s
.m
...m.
m
-,------,---,w-Settlement of SM-25 (SWVH?
0 00
='
=-
=
=_ _=!
_ _ =
=
=
=-
_i
-0.10 G)
LL C
-0.20 C
O E
-0.30 0
~~W o
r (f)
-0.40
~
-0.50 -- t 91 92 93 94 95 96 97 i
4 Time in '/ ears l
Settlement of SM-26 (SWVH) 0.00
- - x:
-0.10 g
O LL
.E
-0.20
=_=.m=_.
-g 9
.. -. -3 E
-0.30 - 5
="
g t
cr:q-.,
(f)
-0.40 -~-.J 2:l=
-0.50 91 92 93 94 95 96 97 Time in Years
__._m.,
. m
-am.. ---
A
.a
Settlement of SM-27 (SWVH) 0.00
_1
- - - -
=_
=3_,_
g
-0.10
~~~~~ l o
.x c
_ 0. 2 0
_e
, mm e C
O
__.__.j_ _
E
-0.30 __:_ '
CD
~
=4 Jb I
0.40 (j)
-0.50 l-91 92 93 94 95 96 97 Time in Years r
a,n'
- - - -x--.a v-
4-e-
a
- =
~ - -
Settlement of SM-28 (SWVH?
0.00
=-
=-
=.
=_
=.
=
=;
=
diu I
-0.10 _C:._
yg O
Ei;_.
_-. : =
-+
E
-0.20
--~~
= =. = _ - -
4J C
x::..
9
~~=
E
-0.30 g
~4 Jb (f)
-0.40
-0.50 l
91 92 93 94 95 96 97 Time in Years
1 p' ~
- u,,
t UNITED STATES
[
j NUCLEAR REGULATORY COMMISSION
,f WASHINGTON, D C. 20%!W001 o
'% **.../
FA?ED FROM THE DIVISION OF WASTE MANAGEMENT (DWN/NMSS)
FAX.Ul8ER:
(301) 415-5398 VERIFICATION:
(301) '415-7445/7438 LOCAL:
LONG DISTANCE:
Y bhn b
oO 804 - 19 } - 619 B l
3 FM #.
3, LOCATION:
VERIFY:
i 2.
FAX #:
LOCATION:
VERIFY:
I IRNBER 0F PAGES PLUS C0VER SHEET D-FRON:
Tl ~
W~
1^
MAIL STOP-PHONE:
1 i
NRC/NM5S/DUM TEL:301-415-5398 Mar 18'97 15:4E Transmit Confirmation Report No.
006 Receiver 8042936188 Transmitter NRC/NMSS/DUM Date Mar 19'97 15:45 Time 07'33 Mode Norm Pages 12 Result OK 4
9