' F Aag C'8' 8 '

UNITED STAVES ATOMIC ENERGY COMMISSIO%

OlVISION OF COMPLI ANCE I

INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT f

"fMCE,eSEE

1. R EGION A L OF FIC E Virginia Commonwealth University U. S. Nuclear Regulatory Comatission 5

1200 East Broad Street Office of Inspection and Enforcement Richmond, Virginia 23219 230 Peachtree Street, N.W.

.\\

Atlanta, Oeorgia 30303

3. DOL M ET NUM BER(S)
4. l.lC E N SE N UM B E R($)

5, D ATE OF INSPECTION h 5- 00048-19

6. lHSPECTION FINDINGS The inspection was an examination or the activities conducted under your license as they relate to radiation sarety and to compliance with the Commission's rules and regulations and the conditions or your license. The inspection consisted or selectise esaminations or procedures and repre.

4 sentative rect. Js. interviews with personnel, and observations by the inspector. rhe rindings as a result of this inspection are as rollows:

l O No items of noncompliance or unsafe conditions were found.

t The fo!!owing items of noncornpliance related to records signs, and labels were found:

O A. Rooms or areas were not properly posted to in 'icate the presence of a RADI ATION AREA.10CFR 20.203(b)or 34.42 O

B. Rooms or areas were not properly posted to indicate the presence of a lilGil RADIATION ARE A.

10 CFR 20.203(c)(1) or 34.42 O

C. Rooms or areas were not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AREA.

10 CFR 20.203(d)

O D. Rooms or areas were not properly posted to indicate the presence of R ADIOACTIVE M ATERI AL.10 CFR 20.203(e)

O E. Containers were not properly labeled to indicate the presence of RADIOACTIVE MATERIAL.

10 CFR 20.203(f)(1) or (0 (2)

F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not properly posted or made available.10 CFR 20.206(b)

G G. Form AEC.3 was not properly posted.10 CFR 20.206(c)

O lt Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)

O

1. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)

O

1. Records of receipt, transfer, disposal, export or inventory of licensed material were not properly maintained.

10 CFR 30.51,40.61 or E5i O

K. Records ofleak tests were not maintained as prescribed in your license, or 10 CFR 34.25(e)

O L. Records ofinventories were riot maintained.10 CFR 34.26 O

M. Utilization logs were not maintained.10 CFR 34.27 O

N. Records of radiation survey instrument calibration were not maintained. (O CFR 34.24 O

O. Records of teletherapy electricalinterlock tests were not maintained as prescribed in your license.

O P. Other

~t Ec co.nviance inw.rwr>

^ The AEC Compliance inspector has explained and I understand the items of noncompliance hsted above. The itema 01 noncompliance will be corrected within the next 30 days.

l (Date)

(f.tcensee Representative Title or Pmision

..