Text
._- --_ _ _ _
ronu rec m U.S. NUCLEAR REGUL ATORY COMMISSION (3. rn orriet or INSPCCTloN ANo ENFORCCME NT
'r6 j
r.,
INSPECTION FIND!NGS AND LICENSEE ACKNOWLEDGMENT LtC E N S E E,
- 2. R E GIO N A L O F FIC E DO j f,,y COrnmiElon
'/N L()
/
- l g;;;ign cnd Enforcement k I,h5fMLShd Flcza Drive, Suite 1000
- 3. DOI E T NUMulfH($)
Arlington, Texas 76012 g
]
mhygQ
- 4. LIC ENSE NUM B EM(S)
- 3. D ATE OF INSPECTION 24-/7445 OIE H d 72
- 6. INSPECTION FIN DlHGS The impection was an esamination of the activities conducted under your heense as they relate to radianon sartly and to compliance with the Comnmsion's rules and regulations and the conditions or your license.1 he in,pection consisted or >clective examinations of procedures and repre.
sentative records, interviews with personnel, and observations by the impector. T he rindings as a result or this inspaton are as follows:
L No items of noncornpliance or unsafe conditions were found.
The following items of noncompliance related to records, signs, and labels were found:
O A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10CFR 20.203(b)or 34.42 O
B. Rooms or areas were not properly posted to indicate the presence of a IllGli RADI ATION AREA.
10 CFR 20.203(c)(I) or 34.42 O
C. Rooms or area; weic not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AREA.
O D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE M ATERI AL.10 CFR 20.203(e)
O E. Containers were not properly labeled to indicate the prmence of RADIOAC flVE MATERI AL 10 CFR 20.203(f)(1) or (f)(2)
O F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not prope :y posted or made available.10 CFR 20.206(b)
O G. Form NRC-3 was not properly posted.10 CFR 20.206(c)
O 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.40l(a) or 34.33(b)
O
- 1. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)
J. Records of receipt, transfer, disposal, export or inventory oflicensed material were not properly maintained.
10 CFR 30.51,40.61 or 70.51 O
K. Records of leak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c)
L. Records ofinventories were not maintained.10 CFR 34.26 O
M. Utilization logs were not maintained.10 CFR 34.27 O
N. Records of radiation survey instrument calibration were not maintained.10 CFR 34.24 O
O. Records of teletherapy electricalinterlock tests were not maintained s prescribed in your license.
F. Other I
bW p
f (ARC Inspector)
' The NRC Inspector has explaink.Le11Il I understand tMiterns of noncompliance listed above. The iterns of noncYa c$26Q22Y will be corrected within the next 30 days, (Date)
(Licensee Representatine - Title or Position)
ORIGINAL TO LICENSEE l