ML20147G039

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept CP-87-124 Re Xomox Valves.Initially Reported on 871230.Installation of Spacers in Unit 1 Xomox Valve Drive Trains Will Be Completed Prior to Fuel Load.Unit 2 Corrective Action Will Be Completed Prior to Fuel Load
ML20147G039
Person / Time
Site: Comanche Peak  
Issue date: 03/03/1988
From: Counsil W, John Marshall
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-124, TXX-88257, NUDOCS 8803080113
Download: ML20147G039 (1)


Text

.

E Log # TXX-88257 File # 10110

--==

908.3 E

E Ref. # 10CFR50.55(e) 1UELECTRIC March 3, 1988 ' D S

%illiam G. Counsil Executan lice Prendent U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 X0M0X VALVES SDAR:

CP-87-124 (FINAL REP 0rtT)

Gentlemen:

On December 30, 1987, we notified you via our report logged TXX-7141 of a reportable deficiency involving Xomox valves. This is a final report to provide the corrective action implementation schedule pursuant to the provisions of 10CFR50.55(e).

The installation of the spacers in the Unit 1 Xomox valve drive trains will be completed prior to fuel load for Unit 1.

Th'e Unit 2 corrective action will be completed prior to fuel load for Unit 2.

1 Very truly yours, W. $. (ot<. s s c' (

W. G. Counsil By J. S. Marshall Supervisor, Generic Licensing WJH/clk c-Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 8803080113 880303 PDR ADOCK 05000445 h

S DCD 1

i 0 400 North Olin Street LB 81 Ektlas. Texas ?$201