r A

GAS RENTALS,.INC./LOWELL GAS-Willie &.Dutton Streets

~/

. [h Lowell, MA.-

01854

/

December 12,.1978 Director Office of Nuclear Material Safety & Safeguards (NPC PUBUC DCCUMDIT ECC" Nuclear. Regulatory Commission Washington,'D.C.

20555 RE:

By-product material license number 20-15003-01

Dear Director:

The enclosed discussion and procedures are submitted in accordance with the quality assurance requirements of 10 CFR Part 71, " Packaging of Radioactive Material for Transport and Transportation of Radioactive Material Under Certain Conditions."-

The Q.A. Program described is to assure that.all planned and systematic actions nee'ssary to provide confidence in the safe use of. gamma projecto.s purchased from Technical Operations, j

Inc., are taken.

The organization, written procedures and ;ns-pection steps to be taken are described.

We hope that this submittal is adequate with respect to the requirements of 10 CFR 71.51 and our specific licensed activities.

Very tntly yours, GAS RENTALS, INC./LCWELL GAS-C jY l W

E.

L. Robinson Vice President - Operations ELR:mac Attachment CC:

Members of Radiation Safety Committee l

11CD 781226ccM

.,4

4 i

I r

l QUALITY ASSURANCE PROGRAM c

r (For use of approved radiographic gamma projectors in

- accordance with requirements of 10 CFR Part 71,5.)

L i

F s

GAS RENTALS,.INC./LOWELL GAS P

4 j.-

k q

r,_-.--9.+.r-v-r--..

... yr p g s.

4 rn k'.e e m4--

-rwe, n

-w,.#.--+-

- +

m--gy#w,

-.,e--g, w.-

- p

-y y

n.-

-..==

a

(

INTRODUCTION The Quality Assurance program is designed to assure that all.

'{

. planned and systematic operations.necessary to prov do confidence j

i in the safe use and satisf actory performance of the radiographic projectors are taken.

The Program describes the organization, written procedures-and inspection steps to be taken in the use of approved devices under our license number 20-15003-01.

DISCUSSION The requirements of Appendix E of 10 CFR Part 71 which are mainly applicable to our field use of radiographic devices are:

organization, purchase and control of licensed devices, inspection procedures, records and corrective action in terms of any discovered deficiencies.

It is also recognized that our approved operating and emergency procedures for licensed projectors is the primary assurance for safety of operation.

i PROCEDURES Oraanization - Our organization is described in Section 6H of our license application.

It consists of the licensee, radiation safety committee, radiation safety officer and radiographers.

With respect to our Q.A. Program, the RSO shall serve as the responsible individual who will insure that the Q.A. Program.is developed, implemented and verified by periodic inspections.

The RSO shall h( ve direct access to top management en all safety and Q.A. aspects of the licensee's radiographic operation.

. -, -. _ - - -...... -, - -, - -. -... ~...

The. radiographer 'shall be responsible for carrying out.tdus 1

Q.A. procedures as. described'as well as maintenance of all rec-ords.

A member of management shall perform the periodic Q.A. Pro-gram audit.

Materials Possession - Prior to purchase and receipt of.

radiographic devices the radiographer shall require' verification of a certificate of compliance from Technical operations, Inc.

A check list shall be completed as follows:

Q.A. Check List

- Certificate of Compliance and Quality Assurance Scarce data p

Size and weight i

Model number Leak Test Certificate Locking device and key Warning labels i

Control Cables j

l Date Radiographers Material Use - The radiographic projector (s) shall be used in accordance with Section 7 of our operating procedures, "Trans-portation and storage of the Radiographic Sources" and Section 8,

" Reports, Records and Inspections. "

As part of daily safety practices the check list shall be maintained whenever the projector is placed into use.

The attached check list snall be considered a part of the material use quality assurance requirements..

,.. ~.. -. _ _..

q LGASiRENTALS, INC./LOWELL GAS dATE L DA,ILY CHECK LIST '(Prior to use. of equipment)

I.

DAILY CHECK LIST FOR' 660 UNIT-USE.

YES NO l

.A.

Survey Meter.

1.. Survey meter (s) left;on?'

.2.

Visible damage to survey / monitoring equipment?

'3.

Battery condition good?

4..

Supply of' spare batteries?

j 5.

Defective survey meter?

l 6..

Comments:

l B.

Storage Container 1.

Locked, properly labeled?

'2.

' Physical damage to storage box or attachments to vehicle?

H 3.

Unusual radiation levels?

4.

Device. secured properly?

1 5.

Comments:

j i

C.

Control Unit (Not' Connected).

1.

Damaged or loose hardware?

2.

Cable & Drive Mechanism working smoothly?

3.

. Odometer zeros properly?'

4.

Guide tubes' damaged?

5.

-Comments:

D.

Model 660 Proiector l

1.

. Visible damage to lock / selector-mechanism?

2.

Control & Guide tube connection points clean?

'3.

Guide tubes clean & undamaged?

4.

Master tube available & snout intact?

5.

Device properly labeled?

6.

Locking mechanism operating?

7.

External radiation levels normal?

8.

Comments:

E.

Personal l.

Pocket dosimeters and film badges available?

2.

Mini radiation' alarm working?

3.

Copy of correction operating & emergency pro-cedures- (660 Projector)?

i 4.

Other personnel, properly equipped?

l 5.

Comments:

l JL/lc

.2/28/74.

Form No. 11

..~.-..

~. _.. -.. _.,

a Audits - Periodic inspections of our Quality Assurance Program shall be conducted by a member of the radiation safety committee other than the.RSO.

This inspection audit shall be conducted at least once each year.

Results and recommendations of such inspections shall be recorded and made available to the Radiation Safety Committee as well as NRC inspectors.

Those activities found to be in violation of these Q.A. procedures shall be promptly I

corrected and reported to appropriate levels of management.

i The following shall be checked during the Q.A. Audit:

Miterials possession check list Materials Use daily log Last date of Q.A. Audit Periodic Management Equipment Inspection log Physical inspection of the licensed material and storage facility Records file Signature and date Notifications - Any deficiencies in terms of Q.A. require-ments of the licensed devices or associated O.A. records shall be promptly brought to the attention of Ehe supplier as well as the RSO.

Notification of the NRC shall be made as appropriate by the RSO.

Trainina -

The radiographer and RSO shall conduct a train-ing session to review the Q. A. Program in order to verify full understanding of the requirements as described above.

.-