Text
-
T~
d 4,
UNITED STATES ph NUCLEAR REGULATORY COMMISSION j(d (Zb )
j REGloN 111 g,
C 799 ROOSEVELT RoAo g.s e,,/
occ~ ctevs. itti~ois e0 37 SEP 181978 University of Notre Dame du Lac License No. 13-01983-15 ATTN:
Dr. John W. Lucey, Chairman Radiation Control Committee Notre Dame, IN 46556 Gentlemen:
This refers to the inspcetion conducted by llr. S. R. Lasuk of this office on August 22-23, 1978, of activities authorized by NRC By-product Materials License No. 13-01983-15 and to the discussion of our findings with you and Messrs. E. Riley and R. Zerr at the conclusion of the inspection.
The inspection was an examination of activities conducted under your license as they relate to radiation safety and to compliance with the Commission's rules and regulations and with the conditions of your license. The inspection consisted of a selective examination of procedures and representative records, observations, and interviews with personnel.
The inspection also included a review of the actions described in your letter dated April 19, 1976, regarding the apparent item of noncompliance found during our March, 1976 inspection and your in-ventory control system. We have no further questions on this matter.
During this inspection, certain of your activities appeared to be in noncompliance with NRC requirements, as described in the enclosed Appendix A.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office within twenty days of your receipt of this notice a written statement or explanation in reply, including for each item of noncompliance: (1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
78/0/30097 l
l
University of Notre Dame g{pygjg7g~
du Lac We will gladly discuss any questions you have concerning this inspection.
Sincerely, T~i CM A. B. Davis, Chief Fuel Facility and Materials Safety Branch
Enclosure:
Appendix A, Notice of Violation cc w/ enc 1:
Central Files Reproduction Unit NRC 20b PDR NSIC
.