i January 28, 1997 1

i William Vercasio, Environmental Radiation Specialist New York State Department of Environmental Conservation 50 Wolf Road 4

I Room 402

)

Albany, New York 12233-7255 1

SUBJECT:

SURVEY OF PUBLIC AREA ADJACENT TO THE FORMER SYLVANIA l

ELECTRIC PRODUCTS, INC FACILITY

Dear Mr. Vercasio:

q On November 19,1996, Steve Shaffer of this office assisted in the survey performed by your office of the public area adjacent to the former Sylvania Electric Products, Inc.

facility Hicksville, New York. The results of Region I laboratory analysis of the four soil samples collected are provided below. Analysis was performed via gamma l

spectroscopy. The uranium-238 activity is inferred from its daughter protactinium-234m.

SAMPLE A I

Sample A was collected approximately one foot from the east side of the fence l

separating the golf driving range from the properties on Cantiague Rock Road and 15 feet south of the property boundary between Magazine Distributors and Gilbert Displays.

Uranium-238 6.8 0.6 picocuries per gram (pCi/g) l Radium-226 1.6 0.5 pCi/g Uranium-235 0.42 0.03 pCi/g SAMPLE B Sample B was collected approximately one foot from the east side of the fence i

separating the golf driving range from the properties on Cantingue Rock Road (O

and 15 feet north of the property boundary between Magazine Distributors and Gilbert Displays.

Uranium 238 11.1 1.0 pCi/g

/

{

. r' j

Radium 226 1.7 i O.7 pCi/g Mp Uranium-235 0.54 i O.04 pCi/g 60005 OFFICIAL RECORD COPY D N P M

  • ALTO 9702060153 970128 PDR ADOCK 070*****

ha.Ciil C

PDR

t;%

1 i.

1 4

1

!' 1 SAMPLE C r

i Sample C was collected approximately one foot from the east side of the fence separating the golf driving range from the properties on Cantiague Rock Road l

}

approximately one foot from the fence on the golf driving range side and 105 j

feet north of the property boundary between Magazine Distributors and Gilbert Displays.

Uranium-238

.3.5 1 0.7 pCi/g j

Radium-226 1.0 0.4 pCilg

]

Uranium-235 0.16 0.03 pCi/g SAMPLE D l

Sample D was collected on the East side of the golf driving range just outside j

j.

the east fence of the golf driving range, approximately 200 meters due east of

]

the location of the other samples. This sample was intended to be j

representative of the background concentrations of radioactive materialin the j

vicinity of the former Sylvania property, i

l Uranium-238 0.9

{

Uranium-235 0.06 0.02 pCi/g l

t in accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, l

Code of Federal Regulations, a copy of this letter will be placed in the Public e

l Document Room. No reply to this letter is required.

{

4 i

Should you have any further questions, please contact Steve Shaffer at (610)-337-i 5256 or Mark Roberts at (610)-337-5256. Your cooperation with us is appreciated.

1 b

Sincerely, 3

Origins' E7.ad IV:

R;n.id 1.15 6 37 1

i Ronald R. Bellamy Ph.D., Chief f

f Decommissioning & Laboratory Branch

.l Division of Nuclear Materials Safety I

t i

Docket No.: 070-00097 License No.: SNM-82 (Terminated) i b

i b

OFFICIAL RECORD COPY l

4

'h i

' cc:

Barry Ballen, President d

Gilbert Displays, Inc.

140 Cantiague Rock Road Hicksville, New York 11801 W. Alexander Williams, Ph.D.

j Designation & Certification Manager, FUSRAP L

U.S. Department of Energy (EM-421) l Washington, DC 20585 l

A.E. Ludwig 1

GTE Operations Support incorporated i

Or'e Stamford Forum Stamford, Connecticut 06904 Barbara Youngberg, Supervisor i

Radiation Section New York State j

Department of Environmental Censervation i

50 Wolf Road j

Room 402 Albany, New York 12233-7255 4

i pistribution:

i PUBLIC i

Nuc!aar Safety Information Center (NSIC) j Region i Docket Room (w/ concurrences) i.

i i

DOCUMENT NAME: C:\\ TYPING \\ORNL\\SYLVANIA Yo receive a copy of this document, indicate in the box: "C" = Copy w/o attach /enci

  • E" = Copy w/ attach /enci

'N' = No copy OFFICE DNMS/RI lN DNMS/RI g DNMS/RI DNMS/R1 l

NAME SShaffer,2Q/4 RBellpmy

MRoberts A(o CGordanVJ c.,u DATE 01/27/97 01/$97 01/ /97 01/ltv97

]