O r

OBaHelle Pacific Northwest Laboratories P.O. Box 999 Richland, Washington 99352 Teiephone (So9i 942-0855 Telex 324345 j

October 24, 1978 Mr. R. G. Barnes, Manager Technical Development General Electric Uranium Management Corporation Mail Code 858 175 Curtner Avenue San Jose, CA 95125

Dear Bob:

Subject:

Evaluation of Extension of Lacrosse BWR Fuel Bundles from Storage Basket This letter confirms our telephone conversation of yesterday. The

(

calculation requested in your letter to C. L. Brown has been completed.

The KENO-II model consisted of:

Lacrosse BWR Fuel (k. = 1.3519) 3.925 wt% 2350 0.565 in, rod. pitch 10 x 10 rod bundles 9 bundle array (3 x 3) 8.625 in. c-c spacing between bundles in horizontal direction 7.625 in s -

spacing between bundles in vertical direction At least 6 in, of water reflecting array Bundles infinitely tall Note that the stainless steel pipes and basket were not included in the model. The calculation gave a keff of keff = 0.923 i 0.007.

A standard QA check-off sheet is attached.

Please call if you need additional calculations or have any questions.

R. A. Libby Sr. Criticality Safety Specialist RAL/ par

(

Enclosure

8. d ham h cc: _

e Concunence yton E. D. Clayton f File /Lb r

Associate Manager g9Q]

Nuclear Analysis

1 ATTACHMENT:

QA Checks KEN 0 Correct Adequate k

Task Options Mixtures Geometry Histories eff Lacrosse Fuel

>I

'y<./

.t,

\\

Extension from basket QA by RI Scherpelz

(

(