ML20147B195

From kanterella
Jump to navigation Jump to search
Forwards Revised Updated SAR Pages That Have Been Approved for Incorporation Into Next Rev of Updated Sar.Revised Pages Reflect Relocation of Current Fire Protection Tech Spec Requirements & Inclusion of Implied Shutdown Requirements
ML20147B195
Person / Time
Site: Wolf Creek 
Issue date: 01/08/1988
From: Withers B
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
WM-88-0005, WM-88-5, NUDOCS 8801150165
Download: ML20147B195 (10)


Text

W8) NUCLEAR OPERATING LF CREEK 8NY January 8,1988 CNef Executree omcor WM 88-0005 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington D. C.

20555

Reference:

1) ULNRC-1447, dated February 19,
1987, from D.

P.

Schnell, Union Electrio, to NRC

2) WM 87-0068, dated March 2, 1987, from B. D. Withers, WCN00, to NRC
3) ET 87-0155, dated April 17, 1987 from J. A.
Bailey, WCNOC, to NRC
4) WM 87-0300, dated October 30, 1987, from B.

D.

Withers, WCN00, to NRC

Subject:

Docket No.

50-482:

Updated Safety Analysis Report Changes Regarding Fire Protection Requirements Gentlemen:

The purpose of this letter is to transmit revised Updated Safety Analysis Report (USAR) pages that have been approved for incorporation into the next revision of the USAR.

The revised pages reflect the relocation of current fire protection Technical Specification (T.S.) requirements into the USAR, including the incorporation of the implied shutdown requirement of Technical Specification 3 7.10.1 ACTION b.

Reference 1 transmitted an application for amendment to Pacility Operating Licenses NPP-30, for the Callaway Plant, and NPP-42, for Wolf Creek Generating Station.

This amendment request proposed modifying existing license conditions regarding fire protection and placing fire protection requirements in plant procedures and the USAR instead of Technical Specifications.

Marked-up USAR pages showing how the relocated T.S.

requirements would be incorporated into the USAR were provided for information with the amendment request.

Wolf Creek Nuclear Operating Corporation (WCN00) formally endorsed this joint application for amendment in Reference 2.

As a result of initial discussions with members of the Nuclear Regulatory Commission (NRC) Staff, minor changes were made to the original amendment request and transmitted to the NRC Staff by Reference 3 8801150165 880108 PDR ADOCK 050 2

lg P.O. Box 411/ Burlington, KS 66839 / Phone: (316) 364 8831 An Equal opportunny Ernployer M Ft4CVET

.Page 2 of 2.

'WM 88-0005 January 8,-1988 Reference 4.provided' responses to - NRC. S1aff questions identified during subsequent ' discussions concerning the amendment' request.

In response to questions 2 and 6, WCN00 stated that.the implied shutdown requirements of T.S.

3.7.10.1 ACTION b would be retain!d and would not be modified without-prior approval from_the_-NRC and that the proposed-USAR changes would incorporate these statements.

WCN00 further stated ~that the USAR ohanges L

would be finalized in accordance with the normal USAR revision process, as part of the implementation of the propcsed T.S. revisions.

Based on further discussions with the NRC Project Manager for Wolf Creek Generating Station, WCN00 has agreed to process the changes and transmit the approved _ changes to the NRC staff prior to approval of the amendment request.

If you have any questions concerning this matter please contact me or Mr. 0.L. Maynard of r:y staff.

Very truly yours, hhb(= =

Bart D. Withers President and Chief Executive Officer BDW/11k Attachment 0o:

B. L.-Bartlett (NRC), w/a R. D. Martin (NRC), w/a D. W. O'Connor (NRC), 2 w/a

STATE OF KANSAS

)

) SS COUNTY OF COFFEY

)

Bart D. Withers, of lawful age, being first duly sworn upon oath says that he is-President and Chief Executive Officer of Wolf Creek Nuclear Operating Corporation; that he has read the foregoing document and knows the content thereof; that he has executed that same for and on behalf of-said Corporation with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief, e

By N.

Bart D. Withers President and Chief Executive Officer SUBSCRIBED and sworn to before me this M

day of 7a o mej, 1987.

M a

, ' * * * * "..*g l.,

Notary Public g,.*.

D. f f

-Exp. ration Date M,/I[O

. O *. a

  • %:';2....._

1 1

Attachment to WH 88-0005 Page 1 of 7 January 8, 1988 USAR ADDITIONS 9.5.1.7 Equipment Operability The technical requirements of the Fire Protection System (FPS) are described in Table 9.5.1-3.

The Fire Protection Manual (FPM) further describes the operability requirements and actions required, if not operable, of the FPS.

A list of all the surveillance procedures required to prove operability of all FPS equipment is maintained in the FPH.

This list also describes the operability requirement that each procedure covers.

9.5.1.7.1 Fire Detection Instrumentation Operability of the fire detection instrumentation ensures that both adequate warning capability is available for the prompt detection of fires and that Fire Suppression Systems, that are actuated by fire detectors, will discharge extinguishing agents in a timely manner.

Prompt detection and suppression of fires will reduce the potential for damage to safety-related equipment and is an integral element in the overall facility fire protection program.

Fire detectors that are used to actuate fire suppression systems represent a more critically important component of a plant's fire protection program than detectors that are installed solely for early fire warning and notification.

Consequently, the ninimum number of operable fire detectors must be greater.

The loss of detection capability for Fire Suppression Systems, actuated by fire detectors represents a significant degradation of fire protection for any area.

As a result, the establishment of a fire watch patrol must be initiated at an earlier stage than would be warranted for the loss of detectors that provide only early fire warning.

The establishment of frequent fire patrols in the affected areas is required to provide detection capability until the inoperable instrumentation is restored to operability.

9.5.1.7.2 Fire Suppression Systems The operability of the Fire Suppression Systems ensures that adequate fire suppression capability is evailable to confine and extinguish fires occurring in any portion of the facility where safety-related equipment is located.

The Fire Suppression Systems cor.sists of the water system,

spray, and/or sprinklers, Halon, and fire hose stations.

The collective capability of the Fire Suppression Systems is adequate to minimize potential damage to safety-related equipment and is a major element in the facility Fire Protection Program.

w.

Attachment to WM 88-0005

- Page 2 of 7 January 8, 1988 In the event that portions of the Fire Suppression Systems are inoperable, alternate _ backup fire-fighting equipment is required to be made available in the affected areas until the inoperable equipment is restored to service.

When the inoperable fire-fighting equipment is intended for use as a backup means of fire suppression, a longer period of time is allowed to provide an alternate means of fire fighting than if the inoperable equipment is the primary means of fire suppression.

The Surveillance Requirements provide assurance that the minimum operability requirements of the Fire Suppression Systems are met.

An allowance is made for ensuring a sufficient volume of Halon in the Halon storage tanks by verifying either the weight or the level of the tanks.

Level measurements are made by either a U.L.,

or F.M.

approved method, or by ultrasonic measurement corrected for temperature using equipment calibrated to standards traceable to NBS.

The term,

' simulated fire' test signal, is interpreted to mean actuation of an automatic Fire Protection System by any of the release mechanisms provided, e.g.,

fire detectors, hand pull stations, fusible line/ mechanical, manual, hydro / mechanical, etc.

In the event the Fire Suppression Water System becomes inoperable, inmediate corrective measures must be taken since this system provides the major fire suppression capability of the plant.

9.5.1.7.3 Fire Barrier Penetrations The functional integrity of the fire barrier penetrations ensures that fires will be confined or adequately retarded from spreading to adjacent portions of the facility.

This design feature minimizes the possibility of a single fire rapidly involving several areas of the facility prior to detection of and extinguishing of the fire.

The fire barrier penetrations are a passive elemer t in ene facility fire protection program and are subject to periodic inspections.

Fire barrier penetrations, including cable penetration barriers, fire doors and dampers are considered functional when the visually observed condition is the same as the as-designed condition.

For those fire barrier penetrations that are not in the as-designed condition, an evaluation shall be performr.d to show that the modification has not degraded the fire rating of the fire barrier penetration.

During periods of time when a barrier is not functional, either:

(1) a continuous fire watch is required to be maintained in the vicinity of the affected barrier, or (2) the fire detectors on at least one side of the affected barrier must be verified operable and an hourly fire watch patrol established, until the barrier is restored to functional status.

1 v

4 '-.

. Attachment to WM 88-0005-i-

Page 3 of 7 January 8,1988~

9.5.1.7.4 Fire Protection Manual The WCGS Fire Protection Manual explains the requirements for the entire

- fire protection plan.

b h

6 l

(~

i l

l.-

4

,.,,,,,--,vm

--g

-~c-

, ~,

n 3.-

1NKE 9.5.1-3 FEE HUrHTrW mmM1EHEDIL Mpnatetts AHLEMEE TBE mRNCHI4EE 2MM EKDIRIMHf MHS GNITDI Wyman ActXN WFDNemir wpnueggs cn >

Eu g

-t

1. Fire Detecticn L&i mea Hm fx Wxneux the apip-
a. A17, ht less thn a.1. nesvia m*ninn=e Fire Pntartim

@gg O

Irstn =*atim each fire zcre p:o-art that is beirg half cf the early a) restrre to cper-a) Mthin 14 Mnal (HM)

%ug tecthy safety-reintM raini is requiral wmirg axi rxtifien-able status days.

eatirri 7.3.4 c, "o is S

<ruinrmt shall be to be qvrnNe.

tim tyg irwenets:

_m cpnN o.

In ary fire zcre b) eNi+ an b) Mth2n next U " ce irrr==M a-lu rly fire 1bar.

utrh ptrol in the affected arm.

co Y

a.2. Inside u u : - a-8 a) restrie to qxr-a) Mthin 14 O

able senem days.

_G b) inspct affectal b) Ethin next m*=4rnmt zme l inr.

every 8 hauts.

_M c) mnitx cxntain-c) Ethin next nat air tmpern-1 Inr.

tute every lur.

b. Mxe thmihalf cf tle b.1. n*<via

. :.., a erly wmarg arxi a) act=Nie si a) Ethin rrtifirntim type in-hautly fire line stnmots in any fire wtzh ptml in 2meimrwnNa the affected arm.

_m siy fire agressam b.2. Insxie u a :

a systan e = tire a) inspect affwtM a) E thin irmennmt in the une maa zme 1Inr imw=N a every 8 hars

_m

_m with any tso cr nrre b) mnitrr cxntain-b) E thin adjxxrt darsr+4m art air tapera-1Inr incen=*s irrr==Na tute every Inr.

1 NEE 9.5.1-.3 (Murf 2)

FEE NDIKTEM SrSDM 11DEEDIE.my0EBSES Anuoutz Tnet mnsmnerm sysnN B0museetr MIPS UNITDI mrymenscrgM mrpnnager aqumgeggs

2. Fire Suressim
a. %o ormhle fire

& all tices.

a.1. Om gnp hqmble.

a.1 Resttre a) qxr-a.1. Ethin HM Settim E8$

Eter Systan sugtnim pnps able stam 7 days.

7.3.1 S$$

aligped to the fire 2

$mh s#m hmder.

gunch an

  • o F5 m

altemate pnp.

er a,

~

H O

a.2. Wo pnps irrper-a.1 Provide a huhp a.2. Ethm 24 g

able.

fire acim hurs.

co

i ster systen.

g e

o

b. As qmble flow ptth At all tines.
b. Flcw pith fyhla.
b. Provide a bachp fire
b. Ethin 24 1Ri SWm g

mphle of takirg amim wter huts.

7.3.2 m

arrim fran tie WES systen.

l mnlirg lake arxi l

...mrm. :.e tM mter Q dictrihe-im I

pip 3TE witil qmblP secticrn1171rg crntrol

& icnintim mlves to the yani hjdnint curb valves, the last valve ahmd cf the uter f1cw alarm device m erh sginkler or hose stand-pipe, arri tM last valve ahead cf tM dah y valve t

cn exh Ihhge cr Spay Systan reluired to in qmNe pr Ttms: 3 axi 5 of Tnhia 9.5.1-3.

  • If tiese rmiitim: are not net within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> actim shall be initiated to pla the toit in a MIE in shicit tM reprezmt does not apply by p1*-irg it, as amlimbla, in:

a) At letst IDI SDNE(mthin the next 6 hurs, b) At least IDI SimDN mthin tie fn11r=1rg 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, axi c) At least GID SIUIDN mthin the a*=we 24 hatrs He abwe rapire:mt is not mmlimhla in MIES 5 axi 6. }hif fimtima to these r=dr-tm dull not be nade utfrut girr agroual cf the MC.

1NE ?.5.1-3 CHEr 3) e FEE HUncrrn susnM TIDREN.BIQ[FAMMIS JHIJDRE TBE SHIEIIIAM SilSIIM RIGIIIIINNr MD!S GEDITIN Elfilman10THN MJM4Nr W J M M MIS cmb.

3. Spay ard/cr Spny ard/or crirki-Mmver tie
a. Qe or nrre sgay
a. 5krahlie a omtim-
a. Ethin 1 HMentim g y

<t S;rirkler Systm wy putatug ed.mmt beirg ard/cr spankler aus fire witd1 in the inr.

7.3.3 c (D g safety-relatal arms gutecteri is re-systers irrmmhla affectal arm with m

dull be rppmbla quami to le in arms cxntamirg tackp fire agres-O

<pwnble.

rairdant systes cr sim enpN1ity.

rt m,,p, g

b

b. Any other spay and/cr
b. 5krahli+ aninrly
b. Ethm 1 CD

-,ral - syst s fire witdi atrol inr.

g irrranhia-in the affected 6

arm.

g m

4. Ihicn Systms Iblm systms Wmever tie
a. Qe ce nrre Ihicn
a. Fk'ahlia a cntim-
a. Ethin 1 HMcutim uniLg safety-gammt beirg systss irrppmble ous fire wtch in the Inr.

7.3.5 relatal arms shall gttutni is in areas cxntainirg affectai area with te mnrnhia-rapiral to le rtindant systms cr lachp fire apges-cmrnhia-uurauis.

sicn mphility.

b. /ny other Ihlcn
b. Fkrahli+ m bourly
b. Ethin 1 systms irrmrnhia.

fire utch ptznl in hour the affectal area.

5. Fire Ibse Fire hose statims Wmever the Qe cr ntre fire hme Pmade ardvalst Ethin linr HMcatim Statims Irrtar+4rg safety-crpiput in the sentims irrwmbia_

egncity lackup hme if the inop.-

7.3.6 related arms shall arms gua ial gutectim to the ernbla enfim te crembla.

by the statims tapurual area.

is the gunnry is rupuul to nuns cf fire be cpenhia.

rrr+=r+4m in the affectal atm; othendse, WLthin 24 Ints.

- - w

1NIE O.5.1-3 (9Eu'r 4)

FIIE HUncrru mmM1K2AM EEQUEEMNIS ME.EMEE TEE mRECHIME

  • EUM EEUIBlitelt NHS EMullTIN HIG3RIED ACTEN RENEIMMr Et]rumMRes
c. c >
6. Fire Ihrrier All fire barriers At all tices.

Ge cr note

a. Ect=Mia a
a. Within 1 HM #wtirn m m

<t acn B er= rims ad their pnetra-irrrer=Na.

omtiruous fire inr.

7.3.7 gcg tims sernrneirs mtrh cn on side Q w if safety-relatal arms of tie affncteri o5 fzun rrn-safety-Intner m

n rehtsi cr sepnatirg

,g g

g prtiais of rairdnt

b. Verify the crernM1-
b. Within 1 g

systms lushai to ity cf fire detutma inr.

m saSe sherhn dull cn at Imst crie side g

te cpNe.

<f the irrrer=Na t=rrier 8

w

_n_o act=N ia an hautly fire etch patrol.

%