Text
!p----------------------------a--------------------_...y I
I U.S. NUCLEAR REGULATORY COMMIS$10N I
NR.C FORet sis CE3TIFICATE OF COMPLIANCE I
- m
' l
'o c'"
FOR RADIOACTIVE MATERIALS PACKAGES I
f f' i actarocare Nuusta o aavisicN NuueEn 5 'Ac"^Goeuriescarecre suusta a paos suusen
. torat uusen paces I
9176 5
US A/9176/A 1
4
,t if a patAusts I
1:
a inis cert 4at. is isso.o to c.rtiey that tn. pacsaging ano contents descrio d en it.m $ eeso.. m.ets me appsicabi safety standards set vortn en Titi.10 Coo.
I f
of F.deral Regulations. Part 11. "Pacsaging and Transportate ce Radioactiv. Vat. rial" J
I!
e in,s e.n.acar. ao.s noi r... ine cons.gnor eram compnanc...tn any reau.remeni ce in. reguiat,ons ce ine u s o.oanment of Transconanon or ein.<
I It appi,cani. r.guiaiory as.nc..s. inctuo ng in. goveram.ar o, en, cou try inrougn or nio on.cn in pacsage..n e. transpon.o I
n ll
,I 1
- I 3 ty,gigc43
- 3sgom t a eas.s on a sarerv 4 aosis,anga,r,ogrgeyc44,ogogoggc,ag, l
Nuclear Packaging, Inc.
NUPAC application dated October 29, 1982,
)
1010 South 336th Street as supplemented.
)g Federal Way, WA 98003 g
I!
ll 1
, coc ar~uweta 71-9176 il i]l ll
. co oirio s in.s cet,ocat..s cono..ona, upon evioning in. c.au r.m.nis ce to crR a n ri es appocao eno in. cono,i>ons sp c o.o e.so.
a I! s 11 ll (a) Packaging h
t t
i I;
(1) Model Nos.:
NUPAC 14/210L, NUPAC 14/210H, CNSI 14-215H Series A, l
li NUS 14-195L, and NUS 14-195H f
(2) Description
)
I; I
ll Steel encased lead shielded casks for low specific activity material.
L Il The casks are right circular cylinders with a 77.25-inch ID by 80.25-
'l l
)l inch IH cavity.
The walls of the casks contain a lead thickness l'
ranging from 1.25 to 1.88 inches encased in 0.38-inch thick inner l
g steel shell and 0.88-inch thick outer steel shell. The top cover and lt 1;
cask botton are inade up of two steel plates with thickness of 2.0
!r I
inches.
The primary cask lid is secured to the cylindrical cask body
't 1
by eight,1-1/4-inch rachet binders.
An ootional secondary lid is lI 1,
centered in the primary lid and is secured to the primary lid with ll f
eight, 3/4-inch studs and nuts.
Each lid is provided with a Neoprene
}
gasket seal.
The casks may be provided with an optional 12 gauge i
i(l stainless steel liner (seal welded along all edges), an optional lid i
l vent line with pipe plua, and an optional 3/4-inch drain line and pipe
't I
plug. The casks are provided with four equally spaced liftina/ tie-I 1;
down devices.
The primary lid is provided with three lifting lugs and I
1
[i the optional secondary lid is provided with one lifting lug.
The
[
g casks gross weights range from 51,600 to 50,100 pounds, g
I'
,E ll Model 00, Lead Tk, Top Tk, Rotton Tk, Gros s Ut,
l l
Number inches inches inches inches pounds l
Il jI f
il NUPAC 14/210L, NUS 14-195L 82.25 1.25 4.0 4.0 51,600 NUPAC 14/210H, NUS 14-195H 83.5 1.88 4.0 4.0 58,400
't
([l CNSI 14-215H Series A 83.8 1.85 4.0 4.0 50,400 l
l
't l
,1 lj-ill I
l
'l I
l l
l l
0602200114 060219
!;l ADOCK 0710 6
{dR
pum ummmmmm mm m m m m m mm mm m m m -m mmmmm m m m m mm m m m m m m m m mmm1mnaca 1
i s )
CONolTiONS (contunu*d) l
}
Page 2 - Certificate No. 9176 - Revision No. 5 - Docket No.
h 71-9176 j
k
- )
5.
(a)
(3) Drawings I
1
't I!
Model Nos. NUPAC 14/210L and NUPAC 14/210H I
1 N
l The packages are fabricated in accordance with Nuclear Packaging, Inc.
['j j
Drawing No. X-20-204D, Sheets 1 and 2, Rev. No. E.
g 1
N 1
Model Nos. CNSI 14-215H
,I 4
I j
The package is fabricated in accordance with Chen-Nuclear Systems, j
j Inc. Drawing Nos. 24500-08, Sheets 1 and 2, Rev. 2; and 24500-05, j
f Rev. 2.
p 1
It 1
Model Nos. NUS 14-195L and NUS 14-195H E
4:
I
{
The packages are fabricated in accordance with NUS Corporation Drawing
(
1 No. 5025-M-2005:
Sheet 1, Revision No. C; and Sheet 2, Pevision 1,
4 No. E.
1 I
1 (b) Contents I
4:
I
(
(1) Type and-fom of material l
4 R
1 (i) Dewatered, solids, or solidified waste, meeting the requirements
.I t
for low specific activity material, in secondary containers; or
't 2
1 4
(ii) Activated solid camponents meeting the requirements for low I
l specific activity naterial, in secondary containers.
f 4
'E.
g (2) Maximum quantity of naterial per package g_
1 L
d Greater than Type A ouantity of radioactive material which may contain L-4 fissile material provided the fissile material does not exceed the L
l.
limits in 10 CFR 971.53.
The decay heat load is limited to 9 watts.
[
4 ti g
6.
(a) For any package containing water and/or organic substances which could 0
1 radiolytically generate combustible gases, determination must be nade by
'L; 4
tests and neasurenents or by analysis of a representative package such that L
4 the following criteria are met over a period of time that is twice the J
l expected shipment time, j
4 1
1 (i) The hydrogen generated rust be limited to a nolar cuantity that would t
1 be no more than 5% by volume (or equivalent limits for other inflam-1 A
nable gases) of the secondary contaiger gas void if present at STP J
{
(i.e., no more than 0.063 g-noles/f t at 14.7 psia and 70'F); or j
l (ii) The secondary container and cask cavity must be inerted with a diluent h
1 to assure that oxygen rust be limited to 5% by volume in those cortions J
f of the package which could have hydrogen greater than 5%.
L i
E
{
For any package delivered to a carrier for transport, the secondary container c
4 must be prepared for shipment in the same nanner in which determination for 4
qas generation is made.
Shipment period begins when the package is prepared j
1' (sealed) and rust be completed within twice the expected shipment time.
J 1
L 1
e 1
p bT rsainiiir--r-wwwwwwiiirswwwwn-r r----7 r.swwwwwwwwwT r-www-wr w-wwww-wim!
i e
.,------a
a um - -- um um a = mm m = =-- --m m = = = = m a== = m m siiMETF3fl$1
)f h
CNDITI:NS (contonusdI g
, f Page 3 - Certificate No. 9176 - Revision No. 5 - Docket No.
f 71-9176 s
1 d
l1 5
1 R
(l 3
6.
(S) For any package shipped within 10 days of preparation, or within 10 days P
j after venting of drums or other secondary containers, the detemination in t
j (a) above need not be nade, and the time restriction in (a) above does not 4
apply.
\\
W 1l 1
li 1
7.
Maximum gross weight of the contents, secondary containers, and shoring is.
N
[
linited to 20,000 pounds.
lh l
8.
Except for close fitting contents, shoring rust be placed between secondary s
f containers and the cask cavity to minimize movement during normal conditions of
- 4 trans port.
R g
e 9.
The lid and shield plug lifting. Tugs must not be used for lifting the cask, and il l
must be covered in transit.
v g
10.
The cask nust be provided with either (or both) a drain line or a lid vent line
'd A
as shown in the drawing in order to provide a riethod to leak test the package.
El fl 4
[
11.
In addition to the requirements of Subpart G of 10 CFP,Part 71:
h (i) Prior to each shipnent, the packaging Neoprene lid seals must he inspected.
3 The seals must be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.. Cavity drain and vent El 1
lines rust be sealed with appropriate sealant applied to the pipe plug E 3 l
threads.
H E
q (ii) Each cask must meet the Acceptance Tests and Paintenance(Program of Section 8.0!gj q
of the application. Maintenance and Gamma Scanning May be in accordance p
Ej 1
with NUS Process Services Procedures WM-026, Rev. A and llM-013, Rev. E.
In 3-addition,'the cask nust be leak tested at least every twelve (12) months in I
l accordance with Appendix 8.4 of the application or NUS Process Services h) g Procedure !!P-Oll, Rev. E.
g H
E M
[r
- q 12.
The rat::het binders on the cask lid must be torqued to 100+10 ft-lbs.
ka
- 13. The cask body and each cask lid must be marked in accordance with 10 CFR 971.85(c). EL 4
E
[
14.
The packages authorized by this certificate must be transported on a motor
[j g
vehicle, railroad car, aircraft, inland watercraft, or hold or deck of a seagoing g
g vessel assigned for the sole use of the licensee.
g; i
,E; d
15.
The package authorized by this certificate is hereby approved for use under the E
{j general license provisions of 10 CFP 971.12.
16.
Expiration date: flarch 31, 1988.
f di
.E 5..
- EJ 1
2:
A B:
l d'
kL l
L L
4' S
4 El 1
ID s 1
- N f..,,,,,....,,,',,,....v;....,,
- E
,,v,.
..v,c,,,,,.
v,,o., m,mn
e nummmm um m m m mm m m m m mm m m m m m mm e mummmmm mmm m m e m a h am 4' N
CONDtTl:NS (contonutd) g in Page 4 - Certificate No. 9176 - Revision No. 5 - Docket No. 71-9176 h
I N
REFERENCES 4
Nuclear Packaging, Inc. application dated October 29, 1982*.
f lW l
Supplements dated:
February 18 and ffarch 24, 1983*; and January 27, 1986.
Chen-Nuclear Systens, Inc. supplement dated:
January 24,198S.
1 lh NUS supplements dated:
December 14, 1984; and f*ay 14 and November 22, 1985.
6
- See> Docket No. 71-9159
)
FOR THE U.S. NUCLEAR REGULATORY C0!HISSION E
h~ I
,i i
Charl'es' E. MacDonald, Chief Transportation Certification Branch 4
Division of Fuel Cycle and l
Material Safety, fitSS g
FEB19 G:
Date:
.E 6
8 a
s l,j, E
E
'E E
g E
M E
W E
Il i
I
_______________________mmm_ _mm_m
_m ___m__mm___mm.,
- f
'o,,
UNITED STATES 8
NUCLEAR REGULATORY COMMISSION o
t a
WASHtNGTON, D. C. 20555
%,...../
Transportation Certification Branch Acoroval Record Docket Nos. 71-9159, 71-9176, 71-9177, 71-9178, and 71-9179 C of C No.
NUPAC Designation 9159 NUPAC 14/190 (1, M and H) 9176 NUPAC 14/210 (L and H) 9177 NUPAC 10/140 9178 NUPAC 7/100 9179 NUPAC 6/100 (L and H)
By application dated January 27, 1986, Nuclear Packaging, Inc. (NilPAC) requested changes to their referenced package designs to reflect field experience. The ratchet binder torque is increased from 50 ft-lbs to 100+10 ft-lbs and the primary lid gasket thickness may be 0.38 through 0.56-inch thickness.
It was stated that these changes will result in a more reliable seal.
The above certificates have been revised to require the higher torque value and pemit the range in gasket thickness.
The ahve changes will not effect the ability of the casks to meet the requiranents of 10 CFR Part 71.
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date: FEB 191988
a neg g%)
UNITED STATES NUCLEAR REGULATORY COMMISSION 4
5 E
WASHINGTON, D. C. 20655
'+,
- * *,e Transportation Certification Branch Approval Record Docket Nos. 71-9159, 71-9176, 71-9177, 71-9178, and 71-9179 C of C No.
NUS Designation 9159 NUS/14-170 (L, M and H) 9176 NUS14-195 (L and H) 9177 NUS 10-135A 9178 NUS 7-100 9179 NUS 6-80 (L and H)
By application dated December 14, 1984, as supplemented on May la and November 22, 1935, NUS Process Services Corporation (NUS) requested amendments to the above certificates.
The changes involve component and material changes and redesignation of the cask model numbers for packages constructed to the drawings provided by NUS.
Each cask must meet the Acceptance Tests and Maintenance Program of Section 8.0 of the Nuclear Packaging, Inc. application.
In addition, revised Operating, Maintenance, Gamma Scanning, and Leak Testing Procedures applicable to the NUS packages were provided and may be used as applicable and in lieu of pertinent parts of Section 8.0 of the Nuclea Packaging. Inc. application. As a result of operating experience witi, similar packages, the ratchet binders on the cask lid must be torqued to 100+10 ft-lbs.
The above changes will not effect the ability of the casks to meet the reouirements of 10 CFR Part 71.
b Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Paterial Safety, NMSS Date: FEB 191985
.