u.s. NUCLEAR RE ULAToRY CIMMISSC]
I n.o.e pons sie CERTIFICATE CF CIMPLIANCE I
l So c'a 7' FOR RADIOACTIVE MATERIALS PACKAGES I
O REvlSioN NUMBER c PACKAGE BOENTlf tCATioN NUMBER e PAGE NUMBER e TOTAL NuM6tR PAG,5
(
t a CERriFICATE NUMSER 9159 4
USA /9159/A 1
4
't II 2 PREAMBLE l
a This CertifeCate is issued to certafy that the paChSQing and Contents described in item $ below. meets the applicable safety standards set fortn in Tatte to. Code I
of Federal Regulations. Part 71,Pacaagmg and Transportation of Radioactive Material" l
D This certificate does not reheve the consignor from comphance witn any requirement of the regulations of the U S Department of Transportation or otner
'I I
appiscaoie reguiatory ageacies. inciuding the government of any country inrouan or mio wnich the pacmage win be transported I
I, ji I
I i i ry,ggicays msgoN r E sasis or a sa,Erv *Natvsis,REga,ragc44,Ggo, Ego,agc,ag, I
Nuclear Packaging, Inc.
NUPAC application dated October 29, 1982, j
I 1010 South 336th Street as supplemented, j
l Federal Way, WA 98003 ll lll I.
ll
. ooexEr NuMeER 71-9159 l
I! a co~oirioNs This certificate is conditionesupon fulfilhng the requerements of 10 CFR Part 71, as apphcable, anJ the conditions specified below f'
(a)
Packaging i
qi ll (1) lbdel Nos.:
NUPAC 14/190L, NUPAC 14/190M, NUPAC 14/190H, NUS 14-170L, ll I
NUS 14-170M, and NUS 14-170H I
I I
l (2) Description I
il I;
Steel encased lead shielded casks for low specific activity raterial, ll ll The casks are right circular cylinders with a 75.5-inch ID by 73.38-lIl Il inch IH cavity.
The walls of the casks contain a lead thickness
((
ranging from 1.25 to 2.63 inches encased in 0.38-inch thick inner
]
steel shell and 0.88-inch thick outer steel shell.
The top cover and
!g g;
cask botton are made up of two steel plates ranging in thickness from
'g ll 2.0 to 3.0 inches. The primary cask lid is secured to the cylindrical
',l 1' l; cask body by eight,1-1/4-inch rachet binders.
An optional secondary I
lid is centered in the primary lid and is secured to the primary lid
!I f
with eight, 3/4-inch studs and nuts.
Each lid is provided with a j
p Neoprene gasket seal.
The casks may be provided with an optional 12-1 gauge stainless steel liner (seal welded along all edges), an optional li gl:
t l
lid vent line with pipe plug, and an optional 3/4-inch drain line and I
pipe plug.
The casks are provided with four equally spaced lifting / tie-
,I ll down devices.
The primary lid is provided with three lifting lugs and I
(
the optional secondary lid is provided with one liftina lug.
The lf g!
casks gross weights range from 49,200 to 65,200 pounds.
I!
!y I
l Model 00, Lead Tk, Top Tk, Rotton Tk, Gross Wt, 1l.
Numbe r inches inches inches inches pounds l
ll E
l NUPAC 14/190L, NUS 14-170L 80.5 1.25 4.0 4.0 49,200
)
NUPAC 14/190fi, NUS 14-170fi 81.5 1.75 4.0 4.0 53,500 ja
,l lI NUPAC 14/190H, NUS 14-170H 83.25 2.63 5.0 5.0 65,200 ll I
'l ll I
l l
i I
- I 1
ll 1
I I
I l
8602200076sy2pg l
ADO gDR
......._______________u__________________...___.-
l
,I
,.l CoNDITloNS (contonv:d)
'n X
1; Page 2 - Certificate No. 5159 - Revision No. 4 - Docket No. 71-9159 b
ji
.is 5.
(a)
(3) Drawings
[
f Model Nos. NUPAC 14/190L, NUPAC 14/190M, and NUPAC 14/190H 1
L 1
The packages are fabricated in accordance with Nuclear Packaging, Inc.
k j:
Drawing No. X-20-2040, Sheets 1 and 2, Revision No. E.
[
f Model Nos. NUS 14-170L, NUS 14-170M, and NUS 14-170H l
1 b
1 The packages are fabricated in accordance with NUS Corporation Drawing I
l No. 5025-M-2005:
Sheet 1, Revision No. C; and Sheet 2, Revision k
ij No. E.
[
f (b) Contents O.
[ [,'f, r
1 (1) Type and forrof na'terial i
1 l
}
(i) Dewaterkd, solids, or solidified waste, meeting the requirenents
[
g forclow specific activity material, in secondary containers; or y
4; E
t (ii) Activated solid components neeting the requirements for low I
1 specific activity material, in secondary containers.
I A
I j
(2) Maxinun quantity of'naterial per package; l
1l Greater than Type A quantity of~ radioactive material which nay contain s'I q
l' fissile naterial provided the fissile naterial does not exceed the I
1 linits-in 10 CFR 571.53. The decay heat load is limited to 7 watts I
1 for the fiodel Nos. NUPAC 14/190L, NUPAC 14/190M, NUS 14-170L, and NUS I
L[
14-170fi; and 25 watts for the t'odel Nos. NUPAC 14/190H and NUS 14-170H f
casks.
y j
- 4, ik 1
6.
(a) For any package containing water and/or organic substances which could t
[1 radiolytically generate combustible gases, detemination must he made by B-
- 3 tests and neasurements or by analysis of a representative package such that k
j the following criteria are met over a ceriod of time that is twice the l
i expected shipment time:
y 4
'I 1
(i) The hydrogen generated rust be limited to a rolar quantity that would
.h
- 1 be no more than 5% by volume (or eouivalent limits for other inflam-D
)
nable gases) of the secondary contaiger gas void if present at STP 8
ji (i.e., no more than 0.063 g-noles/ft at 14.7 psia and 70*F); or
'j
'f s
q!
(ii) The secondary container and cask cavity must be inerted with a diluent
.g 4
to assure that oxygen must be limited to 5% by volume in those portions
,a f
of the package which could have hydrogen greater than 5%.
,1 1
b f
For any package delivered to a carrier for transport, the secondary container j j!
must be prepared for shipment in the same manner in which detemination for g
1 gas generation is made.
Shipment period begins when the package is prepared
'u 1
(sealed) and rust be completed within twice the expected shipment time.
,h 1
1
}
(b) For any package shipped within 10 days of preparation, or within 10 days
'l after venting of drums or other secondary containers, the detemination in
'g
!j!
(a) above need not be made, and the time restriction in (a) above does not u
1l
- ij a pply.
,u I,
I
h.
mammmmmmmmmmmmmmmmmmmmmmummm-mmmmmmmammmamm-mumum-mmmmT l
CONDITloNS (continu:d) l Page 3 - Certificate No. 9159 - Revision No. 4 - Docket No. 71-9150 j
h i.
I R
- (I 7.
Maximum gross weight of the contents, secondary containers, and shoring is linited to 20,000 pounds.
8.
Except for close fitting contents, shoring rust be placed between secondary g
containers and the cask cavity to minimize movement during nomal conditions of I
trans port.
j 9.
The lid and shield plug lifting lugs must not be used for lifting the cask, and l
must be covered in transit, y
F 10.
The cask must be provided with either (or both) a drain line or a lid vent line p-as shown in the drawing in order to provide a method to leak test the package, j
11.
In addition to the reoutrements of Subpart G o'f 10 CFR Part 71:
l t-(i) Prior to each shipment, the packaging Neoprene kid seals must be inspected.
g The seals must be replaced with new seals if inseection shows any defects I
or every twelve (12) months, whichever occurs first.
Cavity drain and vent t
lines must be sealed with appropriate sealant applied to the pipe plug I
threads.
~
l t
(ii) Each cask must neet the Acceptance Tests and Maintenance. Program of Section 8.0's.
of the application. Maintenance and Gamma Scanning may be in accordance
'I K
with NUS Process Services Procedures ~ WM-026, Rev. A and WM-013, Rev. E.
In
.I 3
addition, the cask nust be leak tested at.least every twelve (12) nonths in
'l d
accordance with Appendix 8.4 of the. application or NUS Process Services l
Procedure WM-Oll, Rev. E.
g i,t 12.
The ratchet binders on the cask lid nust be torqued to 100+10 f t-lbs.
lb W,
I 13.
The cask body and each cask lid rust be marked in accordance with 10 CFR 971.85(c). l 14.
The package authorized by this certificate rust be transported on a motor k
vehicle, railroad car, aircraf t, inland watercraft, or hold or deck of a seagoing g
vessel assigned for the sole use of the licensee.
't p
i '
The package authorized by this certificate is hereby approved for use under the 15.
8 i
general license provisions of 10 CFR 571.12.
j i
16.
Expiration date: March 31,1988.
p l,
p
-p j
't I
t b
'f t
W 3
e l
I
.b n
I l
- I t
m-------------------------------
99-------------n
.....................a h
l ccnom:ns ccontanusc>
, j Page 4 - Certificate No. 9159 Revision No. 4 - Docket No. 71-9159 l
- )
1l1 1
PEFERENCES 1
)
Nuclear Packaging, Inc. application dated October 29, 1982.
- )i Supplements dated:
February 18 and March 24, 1983; and January 27, 1986.
- 1
{
NUS supplements dated:
December 14, 1084; and May 14 and November 22, 1985.
ll 1
- f FOR THE U.S. NUCLEAR REGULATORY C0fift!SSION 1.
1 d/
Charles ~ E. FacDonald, thiET '
j s
Transportation Certification Branch
=1 Division of Fuel Cycle and 1
Material Safety, !fiSS 4,:j Date:
FEB 191986 2
1
- 1 1
4 4
4 4
4 1
4 4
1 4
4
- 4 1
'4 4
4 4
4 1
1
.g i
'3 4
I 4:
.p q
'p.
1 h
4 Ik 1
- s 1
p 4
3 4
E 4:
l 4'
II 4
's 1
0 1
ll 1l
.I t
,_ _ ;n
...,,'o
' UNITED STATES
~g E
NUCLEAR REGULATORY COMMISSION
+
o 3
E WASHINGTON, D. C. 20555
%, *.../
Transportation Certification Branch Accroval Record Docket Nos. 71-9159, 71-9176, 71-9177, 71-9178, and 71-9179 C of C No.
NUPAC Designation
~
9159 NUPAC 14/100 (1, H and H) 9176 PDJPAC 14/210 (L and H) 9177 NUPAC 10/140 9178 NUPAC 7/100 9179 NUPAC 6/100 (L and H)
By application dated January 27, 1986, Nuclear-Packaging, Inc. (NilPAC) requested changes to their referenced package designs to reflect field experience. The ratchet binder torque is increased from 50 ft-lbs to 100+10 ft-lbs and the primary lid gasket thickness may be 0.38 through 0.5F-inch thickness.
It was stated that these changes will result in a more reliable seal.
The above certificates have been revised to require the higher torque value and pemit the range in gasket thickness.
The above changes will not effect the ability of the casks to neet the requirements of 10 CFR Part 71.
Y=k Charles E. ftacDona d, Chief Transportation Certification Branch Division of Fuel Cycle and Paterial Safety, tESS Date: FEB 191986
4g..g'o UNITED STATES g
E o
NUCLEAR REGULATORY COMMISSION 3
E WASHINGTON, D. C. 20555
}
Transportation Certification Branch Approval Record Docket Nos. 71-9159, 71-9176, 71-9177, 71-9178, and 71-9179 C of C No.
NUS Designation 9159 NUS/14-170 (L, M and H) 9176 NUS14-195 (L and H) 9177 NUS 10-135A 9178 NUS 7-100 9179 NUS 6-80 (L and H)
By application dated December 14, 1984, as supplemented on May la and November 22, 1985, NUS Process Services Corporation (NUS) requested amendments to the above certificates. The changes involve component and material changes and redesignation of the cask model numbers for packages constructed to the drawings provided by NUS.
Each cask must meet the Acceptance Tests and Maintenance Program of Section 8.0 of the Nuclear Packaging, Inc. application.
In addition, revised Operating, Maintenance, Gamma Scanning, and Leak Testing Procedures applicable to the NUS packages were provided and may be used as applicable and in lieu of pertinent parts of Section 3.0 of the Nuclear Packaging. Inc. application. As a result of operating experience with similar packages, the ratchet binders on the cask lid must be torqued to 100+10 ft-lbs.
The above changes will not effect the ability of the casks to meet the reauirements of 10 CFR Part 71.
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Paterial Safety, NMSS FEB 191986 Date:
1