AUG.1 81992 License: DPR-53, DPR-69 Docket: 50-317, 50-318 hir. George C. Creel Vice President - Nuclear Energy Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant h1D Rts 2 and 4, Post Of0cc Box 1535 Lusby, hiaryland 20657
Dear hir. Creel:
Subject:
Status of the Calvert Cliffs Emergency Preparedness (EP) Prognun On July 16,1992, hir. T Forgette and others of your staff met with members of NRC regional staff in King of Prussia, Pennsylvania to discuss changes to the EP program that have been implemented for the Calvert Cliffs facility. Additionally, the scenario for the August 1992 partial-participation exercise scenario was discussed. The general topics discussed during this meeting are documented in the enclosed meeting summary.
We believe that the meeting was beneficial to our understanding of how you have developed and plan to implement the changes to your EP program. Additionally, we found the meeting beneficial in that we gained a better understanding of your approach to the development of l
exercise scenarios. NRC staff members will further evaluate your formal submittal of the partial-participation exercise scenario in accordance with NRC IP 82302.
No response to this letter is required. Your cooperation with us is appreciated.
Sincerely, 181nal Signed n,-
&t
>bltt L {L
{tdh%
Richard ooper, Director Division of Radiation Safety and Safeguards Enclesures: as stated
't i" (f%\\I. byL U G j([j h f n
'Eh-4 q%
!F' l
9209030035 920818 kh i di PDR ADOCK 03000317 I
I p
PDR-a
. _ ~
AUG.101992 Italtimore Gas and lilectric Company 2
cc w/ encl:
G. Detter, Director, Nuclear Regulatory hiatters (CCNPP)
R. hiclean, Adminir,trator, Nuclear livaluations J. Walter, Engineering Division, Public Service Commission of hiaryland K. Ilurger, Esquire, h1aryland People's Counsel R. Ochs, Maryland Safe Energy Coalition K. Abraham, PAO (2)
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident inspector State of Maryland (2) i
\\.uYbY A
\\
Al)G.101992 11altirnore Gas and filectric Company bec w/ encl:
Region 1 Docket Room (with concurrences)
C. Cowgill, DRP J. Yerokun, DRP L. Nicholson, DRP S. Greenlee, DRP P. Wilson, SRI - Calvert Cliffs R. lobel, OIIDO R. Capra, NRR D. Mcdonald, NRR DRS/EB SALP Coordinator D. Hohly, EO l-a OFFICIAL RD:6RD C04" w ' ' - - '
N-
--'"'---P"'u'
--+e
'N s
)
AUG.181992 Italtimore Gas and lilectric Company 3
1 DRSS:RI DRSS:RI DRSS:RI DRSS:RI
\\j b*Q h/'n y
gg,
Eckert McCa e bJoyne'-
C.Ix:r 8/ 4/92 8/s /92 8// )/92 8//7/92 OFFICIAL RECORD COPY IE 35
}
hiEETING SUhihiARY Licensee:
Baltimore Gas and Electric Company Facility:
Calvert Cliffs Nuclear Power Plant, Units I and 11 Docket:
50-317 and 50-318 Time and Date:
1:00 p.m., July 16, 1992
Subject:
Status of the Calvert Cliffs Emergency Preps. redness Program Attendecs:
NRC L. Nicolson
' Chief, Reactor Projects Section No. l A, DRP E. hicCabe Chief, Emergency Preparedness Section, DRSS
. J. _ Lusher Emergency Preparedness Specialist, DRSS L. Eckert Emergency Preparedness Specialist DRSS Licensee:
.T. Forgette
- Supervisor, Emergency _ Preparedness-E. Roach Emergency Planner G. Rudiger Emergency Planner Iepics Discussed:
Changes to the Emergency Action Level (EAL) scheme Changes to Licensed Operator Retraining program Training Instructions Proposed implementation schedule for the next revsion to ERPIP 3.0 Proposed implementation plans concerning the Nuclear hianagement and Resources Council (NUhiARC) EAL methodology Proposed 1992 Exercise Scenario Scenario development methodology
EAL INTERIM ACTIONS UNR 92-06-02 April 21 Identify EALs of concern (General Emergency 11 &I 3) 24 LORTcndorse EALs to be addressed May EPU/LORT develop scenarios and teining material to i ERPIP revision needs identified as a result of scenario I
address apparent difficulties ofimplementing Plan for and training development work.
fast breaking scenarios (includes considerations from ERPIP roision draft.
personal notes and IP 82201).
June 12 Issue draft EAL tabs for technical reicw June 12 ERPIP 3.0
- complete" for training prep.
June 19 Training sessions begin; 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> ( + ): classroom,ahiut I hour; simulator, balance of time 26 Technical review comments received 23 Training 30 Training July 7 Training July 22 1ssue for POSRC review i
17 Training 21 Training 28 Training July 27 EAL revision to Phn' ting & Photographic August 4 Training August 5 POSRCpresentation 11 T.aining 21 Training 25 Trair3ng i
Sept.1 Implementatioa Rev.3
.