{-G MaineYankee-

+

-}

HEUA8tf ELfCTROTY FOR MAINE Sif4CE 1972 EDISON DRIVE AUGUSTA, MAINE 04LO + (207) 622 4868 August 4 1992 MN-92-80

-JRH-92-68

' UNITED STATES NUCLEAR REGULATORY COMMISSION

. Attention: ' Document Control Desk Washington _, DC. 20555

References:

(a) License No..DPR 36 (Docket No. 50-309)

-~(b).; MYAPCo Letter to USNRC dated December 29, 1989 (MN-89-156)

Subject:

_ Inservice Inspection Testing Program Gentlemen:.

.y

..._.. Maine Yankee' submitted a-Relief Response-(V-6), Reference (b), of our Inservice Testing-(IST) program requiring. check-valve CH-72 (charging)-to be disassembled and

' inspected every refueling; outage in' lieu of quarterly closure testing while at power.

4 LDuring the 1992: refueling' disassembly, the threaded bonnet became galled, preventing-

~

removaldwithout. damage. The bonnet was tightened-and the-disassembly was cancelled because there was not a suitable replacement valve available.

~

- Theivalve operability was-reviewed?using the guidelines from Generic Letter 04 for extending the dis, assembly / inspection frequency of'a check valve. CH-72 was disassembled in 1990;- the~ measurements of the wear areas and clearances _were found q

zto.be within the manufacturers service tolerances. CH-72 was successfully full flow

tested open~in March 1992.--

-: Maine Yankee will be writing:a :" Cold Shutdown Justification" for inclusion-in the Lthird interval IST program. -Please' contact us_ should you;have any questions 1

regarding this matter.-

!Very_truly;yours, 29/9 Avh rn James--R. Hebert,-Acting Manager 3

1 Licensing &-Engineering Support Department F J.VW/sjb t

L

'c: ~ iMr.1 Thomas'T. Martin' -

Mr. ; Charles ' S. = Marschall o

Mr. E..H.'Trottier Hr.LPatrick J. Dostie i k

'920811000219'20804- -- 0 PDR :ADOCK- 05000309 -

,h pp PDR O

m urgte.uceas.nr,

  • ~O

.,a

-