May 23, 1997 l

Dr. Norman R. Scott-Vice President for Research and

. Advanced Studies Cornell University 314 Day Hall l

Ithaca,'New York 1483-2801 1

i SU8 JECT:

ISSUANCE OF AMENDMENT NO. 11 TO FACILITY OPERATING LICENSE NO. R-80 CORNELL UNIVERSITY TRIGA REACTOR (TAC NO. M98229)

Dear Dr. Scott:

l The Commission has issued the enclosed Amendment No.11 to Facility Operatirq License No. R-80 for the Cornell University TRIGA Reactor.

The amendment

. modifies the line orgariization which directs the TRIGA Reactor in response to l

your letter of March.7,,1997...

g

(

l A copy of the related safety l evaluation supporting Amendment No.11 is also

' enclosed.

' Sincerely

/ =,'.- '

Original signed by:

,<i l T F_Theodofe,S, Michaels, Senior Project Manager

'?

i ?,,. '

Non-Power Reactors and Decommissioning

~,,4

,r'.

"4

  • Project Directorate l

Yj

't

! Division ofileactor Program Management

/,.,.

~~

Office' of *huclear Reactor Regulation DocketNo.'50-157 x

,1"

+6.

,)

,. m

~

Enclosures:

1'. ' Amendment No. 11; L

I

,,2.? Safety Evaluationi

~

cc w/ enclosures:

4 m.

See next pag.

a., <

DISTRIBUTION:~ n

-Docket File 50-157 TMartin 0GC (015-B-18)

Gilill (2)(T-5C-3)

PUBLIC SWeiss TMichaels

'PDND r/f EHylton Region I I

A PDND:PM P

A PDND:(A)D TMicha s

. ton MMendonca f/ / /97 6///97 y

f'/97 g 60 /97 0FFICIAL RECORD COPY l

DOCUMENT NAME: A:\\ AMEND 10 g

OYOI i

3 260049 ggg11Rt0M L

i 9705290066 970523 PDR ADOCK 05000157 P

pop

ln

[=

UNITED STATES s

j NUCLEAR REGULATORY COMMISSION WASHINGT%, D.C. 20mS4001 May 23, 1997 l

Dr. Norman R. Scott Vice President for Research and Advanced Studies Cornell University 314 Day Hall Ithaca, New York 14853-2801

SUBJECT:

ISSUANCE OF AMENDMENT NO. 11 TO FACILITY OPERATING LICENSE NO. R-80 l

CORNELL UNIVERSITY TRIGA REACTOR (TAC NO. M98229)

Dear Dr. Scott:

l The Commission has issued the enclosed Amendment No. 11 to Facility Operating License No. R-80 for the Cornell University TRIGA Reactor. The amendment modifies the line organization which directs the TRIGA Reactor in response to your letter of March 7,1997.

A copy of the related safety evaluation supporting Amendr.ent No.11 is also enclosed.

Sincerely, S-l Theodore S. Michaels, Senior Project Manager Non-Power Reactors and Decommissioning i

Project Directorate l

Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-157

Enclosures:

1.

Amendment No. 11 2.

Safety Evaluation l

cc w/ enclosures:

See next page I

i i

C;c.1311 University Docket Nos. 50-97/157 c;-

l Di,ector, Bureau of Radiation, DHSR NYc Department of Environmental l

Conservation 50 Wolf Road Albany, New York 12223-7255 Dr. Iloward Aderhold School of Applied and Engineering Physics Ward Laboratory Cornell University l

Ithaca, New York 14853 l

Mr. John P. Spath NYS Energy Research and Development Authority Corporate Plaza West i

286 Washington Avenue Extension Albany, New York 12203-6399 l

l l

i 4

4 4