RC-97-0108, Application for Amend to License NPF-12,revising Testing Methodology Utilized by VCSNS to Determine Operability of Charcoal Adsorbers in Engineering Safeguards Features Air Handling Units
| ML20141K242 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 05/21/1997 |
| From: | Gabe Taylor SOUTH CAROLINA ELECTRIC & GAS CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20141K245 | List: |
| References | |
| RC-97-0108, RC-97-108, NUDOCS 9705280406 | |
| Download: ML20141K242 (5) | |
Text
....
-. _. -. =
south Carolina Electric & Gas Company Gary J. Taylor P.o. Box 88 Vics President Jenkinsvule, sC 29065 Nuclear operations (803) 345-4344 E
May 21,1997 RC-97-0108 Document Control Desk U. S. Nuclear Regulatory Commission
]
Washington, DC 20555 Attention: Mr. A. R. Johnson i
Gentlemen:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)
DOCKET NO. 50/395 OPERATING LICENSE NO. NPF-1.2 TECHNICAL SPECIFICATION CHANGE REQUEST - TSP 960005 CHARCOAL ADSORBER TESTING
REFERENCE:
Mr. S. A. Byrne (SCE&G) to Ms. Tilda Y. Liu (NRC) letter, RC-96-0039, dated February 10,1996 South Carolina Electric & Gas Company (SCE&G), acting for itself and as agent for 1
South Carolina Public Service Authority, hereby requests an amendment to the Virgil C.
Summer Nuclear Station (VCSNS) Technical Specifications (TS). This request is being submitted pursuant to 10 CFR 50.90.
The proposed changes will revise the testing methodology utilized by VCSNS to i
determine the operability of the charcoal adsorbers in the Engineering Safeguards Features (ESF) air handling units. Technical Specifications 3/4.7.6, " Control Room Normal and Emergency Air Handling System," and 3/4.9.11, " Spent Fuel Pool Ventilation System," charcoal adsorber testing methodology are being changed to reference ASTM D 38031989 instead of ANSI N509-1980.
j Currently, VCSNS tests the charcoal adsorbers in the ESF air handling units per ANSI N5091980. Although thin method of testing provides assurance that the charcoal i
adsorbers will perform their design function, it is being revised to reflect our statement in the referenced letter that SCE&G would submit a TS change to implement standard ASTM D 3803-1989.
The TS change request is contained in the following attachments:
I Attachment i Explanation of Changes Summary Marked-up Technml Specification Pages g p 'I l Revised Technical S;weification Pages I
'MOOGO y
gggsaggggggjggg,3 e
lillEl5JRlIjillH
Docum:nt Control Desk TSP 960005 l
RC-97-0108 Page 2 of 3 Attachment ll Safety Evaluation l
Attachment lli No Significant Hazards Evaluation i
This proposed amendment has been reviewed and approved by the Plant Safety Review Committee and the Nuclear Safety Review Committee.
These statements and matters set forth herein are true and correct to the best of my knowledge, information, and belief.
l Should you have questions, please call Mr. Jim Proper at (803) 345-4088.
Very tr i
- urs, W
ryJ.T r
CD/GJT/dr Attachments (3) c:'
J. L. Skolds
)
W. F. Conway R. R. Mahan (w/o Attachments)
R. J. White L. A. Reyes NRC Resident inspector J. B. Knotts Jr.
M. K. Batavia i
K. R. Jackson DMS RTS (TSP 960005)
File (813.20) i 4
NUCLEAR EXCELLENCE - A SUMMER TRADITIONI
Document Control Desk l
TSP 960005 l
RC-97-0108
[
Page 3 of 3 STATE OF SOUTH CAROLINA :
- TO WIT :
COUNTY OF FAIRFIELD j
l hereby certify that on the 2/
day of /fle T 19 72 before me, the subscriber, a Notary Public of the State of South Carolina, personally appeared Gary J.
Taylor, being duly sworn, and states that he is Vice President, Nuclear Operations of the South Carolina Electric & Gas Company, a corporation of the State of South Carolina, that he provides the foregoing response for the purposes therein set forth, that the statements made are true and correct to the best of his knowledge, information, and belief, and that he was authorized to provide the response on behalf of said Corporation.
l WITNESS my Hand and Notarial Seal A
e g// Notary Public My Commission Expires Zlv 24, 2oof Date l
l l
v l
l l
NUCLEAR EXCELLENCE - A SUMMER TRADITION!
Docum:nt Control D:sk Attachment i TSP 960005 RC-97-0108 Page 1 of 2 SCE&G - EXPLANATION OF CHANGES Paae Affected Bar Description of Chance Reason for Chance Section i
3/4 7-15 4.7.6.c.2 1
Replaced " ANSI N 509-1980, The proposed change at a relative humidity of 70%
incorporates the statement and 25'C with a methyl made in the letter from iodide penetration of < 1%"
Mr. S. A. Byrne (SCE&G) to with " ASTM D 3803-1989, at Ms. Tilda Y. Liu (NRC) dated a relative humidity of 70%
February 10,1996. The and 30 C with a methyl letter stated SCE&G's intent iodide penetration of <
to incorporate ASTM D 3803-2.5%."
1989 into requirements for I
testing the charcoal adsorber l
in the ESF air handling units.
I 3/4 7-15 4.7.6.d 2
Replaced " ANSI N 509-The proposed change j
l 1980, at a relative humidity of incorporates the statement 70% and 25'C with a methyl made in the letter from l
iodide penetration of < 1%"
Mr. S, A. Byrne (SCE&G) to with " ASTM D 3803-1989, at Ms. Tilda Y. Liu (NRC) dated a relative humidity of 70%
February 10,1996. The and 30 C with a methyl letter stated SCE&G's intent iodide penetration of <
to incorporate ASTM D 3803-2.5%."
1989 into requirements for testing the charcoal adsorber in the ESF air handling units.
3/4 9-13 4.9.11.b.2 1
Replaced " ANSI N 509-The proposed change 1980, at a test media incorporates the statement l
temperature of 30 C"with made in the letter from l
" ASTM D 38031989, at a Mr. S. A. Byrne (SCE&G) to relative humidity of 95% and Ms. Tilda Y. Liu (NRC) dated 30 C with a methyliodide February 10,1996. The penetration of < 2.5%."
letter stated SCE&G's intent to incorporate ASTM D 3803-1989 into requirements for testing the charcoal adsorber in the ESF air handling units.
1 l
t 4
Docum:nt Control Disk Attachment i TSP 960005 RC-97-0108 Page 2 of 2 l
Paae Affected Bar Description of Chanae Reason for Chance Section 3/4913 4.9.11.c 2
Replaced " ANSI N 509-The proposed change 1980, at a test media incorporates the statement temperature of 30 C"with made in the letter from
" ASTM D 3803-1989, at a Mr. S. A. Byrne (SCE8G) to relative humidity of 95% and Ms. Tilda Y. Liu (NRC) dated 30 C with a methyliodide February 10,1996. The penetration of < 2.5%."
letter stated SCE&G's intent to incorporate ASTM D 3803-1989 into requirements for testing the charcoal adsorber in the ESF air handling units.
l l
1 i
-- -__