May 20, 1997 Carl Terry, BWRVIP Vice-Chairman Niagara Mohawk Power Company Post Office Box 63 Lycoming, NY 13093
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR TOPICAL REPORT EPRI TR-105697, "BWR VESSEL AND INTERNALS PROJECT, BWR REACTOR PRESSURE VESSEL SHELL WELD INSPECTION RECOMMENDATIONS (BWRVIP-05)"
Dear Mr. Terry:
By letter dated September 28, 1995, as supplemented by letter dated June 24, 1996, the Boiling Water Reactor Vessel and Internals Project (BWRVIP) submitted Topical Report EPRI TR-105697, "BWR Vessel and Internals Project, BWR Reactor Pressure Vessel Shell Weld Inspection Recommendations (BWRVIP-05)," for NRC review.
The report was intended to derr.onstrate the adequacy of alternative inspection requirements which would significantly reduce the extent of volumetric inservice inspections currer,tly required on BWR reactor pressure vessel shell welds. The NRC staff transmitted, by letters dated April 2 and May 20, 1996, two Requests for Additional Information (RAls).
In addition, several meetings were held between the BWRVIP and the NRC staff to discuss this issue, including a meeting with the NRC Commission on May 12, 1997.
During that meeting, the NRC staff committed to issuing a final safety evaluation of the BWRVIP-05 report within 6 weeks.
In order for the NRC staff to complete the assessment of this report, we request that the BWRVIP provide to the NRC staff an update providing the most current information in Appendix A of the BWRVIP-05 report.
We request that this update include:
(a) the information in the table for all reactor pressure vessel beltline shell weld inspections performed on U.S. BWRs (b) the location of the shell welds (e.g., beltline or other location)
(c) the year (s) the inspection (s) were performed (d) the types of inspections performed (e.g., UT, visual or enhanced visual, PT, RT), including the results of the inspections (e) the qualification standards used to perform the inspection (s)
We request a response to the above within 15 days of receipt.
If you have any l
questions, please contact Keith Wichman of my staff at (301) 415-2757.
Sincerely, l
ORIGINAL SEED 3Y Brian W. Sheron, Director Division of Engineering f
Office of Nuclear Reactor Regulation gD l
cc:
See next page DISTRIBUTION:
bb~
[7'/W NRR/EMCB Reading Y' N SM PUBLIC
- Ceni,ralhFileg MEMayfield eFid-DOCUMENT NAME
- C:\\8WRVIP\\BWRVIP05,RI3 "C" = copy "N" = No copy
- See Pr rrence EMCB: LPM lC EMCB:SLS lC EMCB:SC lC! EMCB:BC l C f $lhD /
lC CECarpenter* 4 RMiermann*
KRWichman*
JRStrosnider*
'BWSh@n f[7[
05/15/97 U'
05/H/97 05/I6/97 05/18/97 fflo/97 0FF.QIAL(RECORDCOPY, l
[
97052e0081 970520 C
PDR TOPRP EXIEPRI C
e Carl Terry,
cc:
Robert Keaten, Executive Chairman Steve Leonard, Technical Chairman BWRVIP Inspection Task BWRVIP Inspection Task GPU Nuclear Niagara Mohawk Power Company ESB1 One Upper Pond Road, Bldg F Post Office Box 63 Parsippany, NJ 07054 Lycoming, NY 13093 George Jones, Executive Chairman John Wilson, Technical Chairman BWP. VIP Mitigation Task BWRVIP Mitigation Task Pennsylvania Power & Light Public Service Electric & Gas Co.
A6-1 N51 Two North Ninth Street Post Office Box 236 Allentown, PA 18101 Hancocks Bridge, NJ 08038 Bill Campbell, Executive Chairman Bruce McLeod, Technical Chairman BWRVIP Repair Task BWRVIP Repair Task Carolina Power and Light Company Southern Nuclear Operating Co.
411 Fayetteville Street Post Office Box 1295 Raleigh, NC 27602 40 Inverness Center Parkway Birmingham, AL 35201 Warren Bilanin, EPRI BWRVIP Manager Vaughn Wagoner, Technical Chairman Electric Power Research Institute BWRVIP Integration Task 3412 Hillview Ave.
Carolina Power & Light Company Palo Alto, CA 94304 One Hanover Square 8C1 P.O. Box 1551 Raleigh, NC 27612 Robin Dyle, Technical Chairman BWRVIP Assessment Task Southern Nuclear Operating Co.
Post Office Box 1295 40 Inverness Center Parkway Birmingham, AL 35201 i
I
.