D ve Mirey South:rn Nucl::r Vice President Opertting Compa y Farley Project P0. Box 1295 Birmingham, Alabama 35201 Tel 205.992.5131 SOUTHERN July 11,1997 COMPANY Energy *o Serve YourWorld

Docket Nos.: 50 348 50 '.164 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant Design Basis for Tornado-Generated Missiles Ladies and Gentlemen:

On May 28,1997, Southern Nuclear Operating Company submitted a letter regarding the design basis for tornado-generated missiles at Farley Nuclear Plant. The enclosure to the letter included ten attachments. Attachment 3 is a copy of B-TOP-3, " Design Criteria for Nuclear Power Plants Against Tornadoes," dated March 12, 1970. This document was originally issued as a proprietary document; however, Bechtel confirmed by letter to Southern Nuclear dated July 1,1997 that B-TOP-3 may be released for NRC review as a i

non-proprietary document. The confirmation letter from Bechtel is attached.

Should you have further questions, please contact David Jones of my staff at 205.992.5984.

Respectfully submitted, kW Dave Morey JMG: tormisl. doc Attachment cc: Mr. L. A. Reyes, Region II Administrator 4

Mr. J. I. Zimmerman, NRR Project Manager Mr. T. M. Ross, Plant Sr. Resident Inspector Mr. L. B. Marsh, NRR - Chief, Plant Systems Branch j

9707220332 970711 DR ADOCK 05000348 PDR III!!'-

OM4

[%

b l

5325 Spectrun Drive Frederick, Maryland 21703-8388 (301) 417-3000 July 1, 1997 In reply refer to AP-21586 Mr. D. N. Morey Vice President - Nuclear Southern Nuclear Operating Company Nuclear Generation Department Post Office Box 1295 Birmingham, Alabama 35201-1295 dItention: M. G. Eidson

Dear Mr. Morey:

Joseph M.

Farley Nuclear Plant Operating Services Bechtel Job 23162 Release of B-TOP-3 as Non-Proprietary Bechtel File A-2.4, A-117 As requested by Mr. M. J. Ajluni, SNC, by E-mail dated June 24, 1997, we have reviewed B-TOP-3, " Design Criteria for Nuclear Power Plants Against Tornadoes," dated March 12, 1970 and have determined that this document does not contain any proprietary information.

Subsequent Bechtel Civil Topical Reports, which are non-proprietary, contain similar design criteria information as conveyed in B-TOP-3 and were previously reviewed and accepted by the Atomic Energy Commission.

Therefore, B-TOP-3 may be released for NRC review as a non-proprietary document.

l If you have any. questions or comments, please contact David Murphy at (301) 228-6066.

Sincerely yours, I

J.

E. Love l-Project Engineer JEL/RCG/DWM:amh Enclosures - None BechtelPower Corporation