- C8?og
- i UNITED STATES g-
~j NUCLEAR REGULATORY COMMISSION WASHINGTON D.C. Kil564001
%g * * * * *,$
May 1997 ERRATA to Regulatory Guide 8.39 r
Equations 2 and 3 on page 2 of Regulatory Guide 8.39, " Release of Patients Administered Radioactive Materials," were misstated when the guide was issued in April 1997. Parentheses were omitted from the denominator of both equations. The equations r
should read:
For radionuclides with a physical half, life greater than I day:
34.6 r O. T, (0.25)
D( m ) =
(Equation 2)
For radionuclides with a physical half-life less than or equal to 1 day and if an occupancy factor of 1.0 is used:
D(=)-
(Equation 3)
, T, (1)