6
- 9. NUCLEAR FIEGULATORY COMMISSION U) f, i
. Form NHCC18 l l 10ck'71 CEHTlFICATE OF COMPLIANCE For Radioactive Materials Packages 4
1.(a) Certificate Number 1.(b) Hewision No.
1.(c) Package Identification No.
1.(d ) Pages No. 1.(e) Totaf No. Pages i j 9007 0
fKA/nnq?/Ar 1
o
- 2. PHEAMBLE l
2.(4)
This certificate is issued to satisfy Sections 173.333a.173.394,173.395, and 113.33G of the Dspartment of Transportation Harardous Materials Hegulations (43 CFH 170189 and 14 CrH 103) and Sections 140-19-1Gi and 146-19-100 of the Department of l
Transportation Dangerous Cargoes Hegulations (46 CrH 14G-149), as amendal.
l 2.(b)
The packaging and contents described in item 5 below, rnects the safety standards set forth in Subpart C of Title 10, Code of Federal Hegulations, Part 71, " Packaging of Hadioactive Materials for Transport and Transportation of Radioactive Material Under j
Certain Conditions."
i I
2.fc)
This certificate (foes not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported,
- 3. This certificate is issued on the basis of a safety analysis report of the package design or apdication-3.fa)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
The Babcock & Wilcox Company fluclear fiatorials & Equipment Corporation 609 florth Warren Avenue application dated tiovember 15, 1966, Apollo, Pennsylvania 15613 as supplemented.
3.(c)
Docket No. 71-9007
- 4. CONDITIONS li This certificate is conditional upon the fulfilling of the requirements of Subpart o of 10 CFR 71, es applicable, and the conditions specified in nem neiow.
- 6. Description of Packaging and Authorised Contents, Model Number, Fessile Class, Other Conditions, arul Heferences:
t4 (a) Packaging ij (1) Model flo.: U-10-CL (2) Description Eleven liter polyethylene bottle with a sealed cap contained in two scaled polyethylene or polyvinyl bags, having a minimum thickness of 0.012 inch, with a 5.625-inch ID, 0.188-inch wall thickness by 54-inch long stainless steel vessel with flanged and gasketed closure. The gasket material is Viton, target or blue asbestos compressed asbestos sheet.
The vessel shall be clad with at least 0.016-inch thick cadmium. A 2-inch thick polyethylene-polyester resin composite within an outer container e, hall surround the cadmium wrapped vessel.
The preceding assembly shall be centere1 and supported within a double length 19-inch or 24-inch diameter 16 gage steel drum built to 00T Specification 17H by eight 0.25-inch diameter spring steel rod spacers.
The void between the outer container and the drum shall be filled with vermiculite.
Maximum gross weight of the packaging is 400 pounds.
0601090797 770603 l
PDR ADOCK 07000135 C
PDR i
i
.a
l O
O l
l l
l !
l (3) Drawings l
The container shall be constructed in accordance with fiUMEC l
l Drawing No. 10-0-1278, Rev. 8, or 10-0-1279, Rev. 6.
NUMEC l
Drawing No.10-D-1272, Rev. 6, supersedes NUMEC Drawing l
No.10-0-1272, Rev. 5 in the above referenced drawings.
(b) Contents l
(1) Type and form of material Uranyl chloride solutions having a of material concentration of U-235 not to exceed 350 grams per liter, provided that the minimum free acid is 2 molar.
(2) Maximum quantity of material per package I
10.0 liters of solution.
l (c) Fissile Class I
6.
Filled bottles shall be inspected for defects and held a minimum of
+
l 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before shipment to determine their integrity.
Defective
!5 l
bottles shall not be used.
J 1
l 7.
The regular and periodic inspection required by 171.51(b),10 CFR 71, shall be carried out by Quality Control Department and the Nuclear Safety Engineer.
l 8.
The use of these containers shall be dedicated to the material contents identified above.
The container shall not be re-designated l
and used for the shipment of other material contents.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.
10.
Expiration date: September 30, 1978 l
l e.
a-*-----.
s.
o D
1 REFERENCES Nuclear Materials & Equipment Corporation application dated November 15, 1966.
Supplement dated: October 31, 1969. June 14 and August 10, 1973.
FOR T11E U.S. NUCLEAR REGULATORY COMMISSI0tl
[A%. kk Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and l
Material Safety Date:
JUN 3 1977 i
t I
i I
I l
l....
--