Certificate of Compliance 6272,Rev 1, for Model Poly Panther
ML20141G097
Person / Time
Site: 07000135, 07106272
Issue date: 03/29/1977
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20141G093 List:
References
NUDOCS 8601090773
Download: ML20141G097 (2)


Text

.

O O

Form NRC4118 U.S. NUCLE AR HEGUL ATORY COMMISSION

,,tt 2 CERTIFICATE OF COMPLIANCE gnM For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No 1.te) Total No. Pages 6272 1

USA /6272/B 1

2 2, PRE AMULE 2.(a)

This certificate is issued to satisfy Sections 173.303a,173.394,173.395, and 173.390 of the Department of Transportation Hanedous Meterials Reaulations (40 CFR 170189 and 14 CFR 103) and Sections 14G-10-10a and 146-10-100 of the Department of Transportation Dangerous Cargoes Hegulations (4G CFH 14G-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Hegulations, Part 71. " Packaging of Hadioactive Materials for Transport and Traneportation of Radioactive Material Under Certain Conditions."

2.(c)

This cartificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the packs;e will be transtrarted.

3. This certificate is issued on the basis of a safety analysis report of the package design or aoolication-3.fe) Propered by (Name and address):

3.(b)

Title and identification of report or application:

Nuc1 car Engineering Co., Inc.

Protective Packaging, Inc. application dated P. O. Box 7246 24 June 1974, as supplemented.

Louisville, Kentucky 40207 3.(c) Docket No.

Docket No. 71-6272

4. CONDITIONS This certificate is conditional upon the fulfitting of the requirements of Subpart D of 10 CFn 71, as applicable, and the conditions specified in item 5 below.
6. Descsiption of Petkapng and Authorised Contents, Mudel Nurnber, Fissile Class. Other Conditions, and

References:

(a) Packaging:

(1) Model No.:

Poly Panther (2) Description A protective overpack having a double-walled, low-carbon steel shell (3/16" outer wall and 20 foam (nominally 7" thick)guage inside Nall) with rigid polyurethane thermal-shock insulation between the walls.

The edges of the overpack are reinforced with 10 guage steel angles welded to the outer face of the walls and internal diagonal 14 guage I

steel plates. Overpack lid closure is provided by three 1" steel rods Which extend the full widths welded to an end plate at one end and secured by a pin at the other end.

Enclosed within the overpack is a bolted and gasketed 12 guage low carbon steel inner container.

l The gross weight of the package is about 6100 pounds.

(3) Drawings The overpack is constructed in accordanco with Mechanics Research. Inc.,

Dwg. No. 121347, revisied to 5/21/70.

The waste storage bin (inner l

container) is constructed in accordance with Argonne National Laboratory's Dwg. No. CS-2273.

8601090773 770329 PDR ADOCM 07000135 C

pg

O O

l Page 2 - Certificate No. 6272 - Revision No.1 - Docket No. 71-6272 5.

(b) Contents l

(1) Type and form of material Dry, solid radioactive material within the waste storage bin.

t (2) Maximum quantity of material per package 4

i Not to exceed Type B quantities of radioactivity.

The maximum weight of the contents shall not exceed 3,000 pounds.

6.

Contents within the inner container must be either packed full or must be securely braced to prevent movement.

7.

The cover of the inner container must be secured by at least 20 bolts (5 per side) of not less than 5/16-inch diameter.

i 8.

The package authorized by this cerificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 i

CFR Part 71.

.9.

Expiration date:

February 28, 1980.

l REFERENCES Protective Packtging, Inc. application in behalf of Nuclear Engineering Co., Inc. dated June 24, 1974.

Supplement dated: January 28, 1975.

l t

FOR THE U.S NUCLEAR. REGULATORY COMMISSION s $ k%

Y Charles E. MacDonald, Chief 5

Transportation Branch l

Division of Fuel Cycle and Material. Safety WR 2 01977 l

Date: