O N
iL
(
F;tm NitCC18 U.S. NUCLE An HEGULATOllY COMMISM u2 CEHTiflCATE OF COMPLIANCE
,g c y,
For najioactive Materists Packages 1.fal Certihcate NM, ~ >e 1.(b) Movision No.
1.lc) Packaqe liteni.fiorenn No.
1.(J) Pages No 1.(e) Total No. P ges 0
USA /5419/B( )F 1
4
- 2. Pn[ AMDLE 2.fal This certificate is issual to satisf y Sections 173.3134,173 394.173.395, arsi 173 7)G of the Department of Transportation Hasardous Materials Hegulations (4'J CFit 17018') and 14 Crfl 103) and Sections 14G l3-104 and 146-19-100 of the Department of Transportation Dangerous Cargoes itenutat6ons (40 Cf H 146-143), as amernf al.
2.(h)
The p,ctiaging and contents described in item 5 tielow, rneets the safety standards set forth in Subpart C of litte 10. Code of f eteral Hegulations, Part 71, Packaging of Mahoactive Materials for Transtret arms Transportation of Radioactive Material Under Certain Cormhtions/*
2.fc)
This certificate does not relieve the consignor from comphance w6th any raiuirement of the regulations of the U S. Department of 1ramportatWn or other applicable regulatory agencies. Antluthng the government of any country through or into which the package will be transsortel.
- 3. This certificate is issuc*f on the basis of a ufety an lysis report of the p.xkage des 6gn or apthcatiort-3.f al f repared by (flame and address) 3 (b) Title and kjentification of report or application:
Combustion Engineerings Inc.
Gulf United fluclear fuels Corporation Route 21-A application dated September 15, 1967, as supplemented llematite, Missouri 63047 3 (el nooei No.
- 4. CONDIf10NS This cert 6ficate is corwtitional upon the fulfilling of the reiuirements of Subpart D of 10 CFn 71. as applicable, armi the concfitions specifleil in n.m t, beson.
t,. oeuription of rackagmg.24 Aoihori,as conienis. Modei Numtwr. risinie Crais, einer Co, ni.>ns,.r : nef e,ences-(a) packaging (1) Model flo.:
UtlC-2800
,l.
(2) Oct.cription
, i.
funi element support is a 9" high x 10" wide x 192" long, 7-gaqe steel shaped strongback with adjustabic end clamps and cross support brackets.
The fuel element support is shock mounted to an outor container by shear mounts.
The outer container is a 12-gage steel cylinder 36" 10 x 207" long with flange closure, skids, stacking brackets and roll rings.
(3) Drtwings Container constructed in accordance with @ plied Desiqn Company Drewings flos. 8/4A1 throuqh 874Als H/4A99 through 874All4, and 874All6 throuqh 874A136.
Shippinq arrangement for fuel rod assemblies as shown in United fluclear Corporation l
Drowinq flo. R.E.C. 10253. Rev. O.
Loading arrangments for UllR fuel elements as shown in UtiC Orawing fio. D-304329 I
Rev. 1.
l l
O/,010'#07D/, 770/,03 PDH ADOCK 07000 35 C
PDH t
l-
g g
l I
i (b) Contents (1) Type and form of material (1) Uranium dioxide as Zircaloy clad or stainless steel clad I
i unirradiated PWR and BWR fuel elements of the following i
specifications:
a.
- PWR, b.
BWR Pellet diameter (flom) 0.38" 0.482" i
Fuel length (flom) 122" 108" Rods /clements(Max) 238 36 Cross sectional area (ftom) 8.5" y 8.5" 4.38" x 4.38" U-235 enrichment Max) 4.1 w/o 2.34 w/o U-235/ element (Ma )
17.23 kg 2.34 kg (ii) Pu02 or U02 or mixtures of these materials as sintered ceramic pellets fully clad in 0.035" thick Zircaloy-2 as fuel rods or fuel elements of the following specifications:
_R.0_D
-ELEMEftT Pellet diameter 0.482" 0.482" I
Fuel length 108" 108" 36 Rods / elements 1
Cross sectional area 4.38" x 4.38" U-235 enrichment Nat.
2.34 w/o U-235/ element 1.806 kg 4'
Pu/ rod-clement 0.066 kg 0.594 kg Minimum Pu-240 20.6 w/o 20.6 w/o (2) Maximum quantity of material por package l
(1) For the contents described in 4(b)(1)(i):
4 a.
One (1) PWR fuel element; or b.
Four(4)BWRfuelelements.
(ii) Forthecontentsdescribedin4(b)(1)(ii):
i I
Ninety (90) fuel rods (5.94 kg Pu); or l
a Two (2) fuel elements (3.612 kg U 235 and 1.188 kg Pu).
I i
1 I
.4.~
j O
O' l
l t
(c) Fissile Class I, II and III.
j i
(1) Fissile Class I For the contents described in 4(b)(1) i (i) b and limited in 4(b)(2)(i) b.
l l
(2) Minimum trans' ort (1) For the contents described in p
4(b)((1)(1)a. and limited in index to be shown 4(b) 2)(1)a.:
on label for Class II 0.2 l
(ii) For the contents described in
( i) and limited in 4(b) 7.1 l
l (3) Maximum number of (i) For the contents described in packages por shipment 4(b)(1)(1)a.andlimitedin for Class III 4(b)(2)(1)a.:
l 500 packages 1
i (ii) For the contents described in
)$
4(b)(1)(ii)andlimitedin4(b)
(2)(11).:
17 packages l
l 6.
The packages authorized by this certificate is hereby approved for use under the general licerse provisions of Paragraph 71.12(b) of 10 CFR Part 71.
7.
Expiration date: July 31, 1978.
D l
l l
______________,u
T O
6 I
REFEREf1CES Gulf United flucicar Fuels Corporation application dated September 15, 1967.
{
Supplements dated:
January 9. September 18, and October 1,1969; June 20 and July 22,1970; June 10 and July 27, 1971; tiovember 28, 1972; and April 12, 1973.
FOR Tile U.S. fiUCLEAR REGULATORY COMMISS10ft
& $lk k
Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety Date:
JUN 3 1977 I
,I 4
5 8
4 l
l
.