g Perm NRC418 U.S. NUCLEAR REGULATORY COMMIS$10N g"C R 71 CERTIFICATE OF COMPLlANCE I
For Radioactive Materials Packages ll
+
1.(el CertifRete Numbw 1.(b) Revision No.
1.(c) Package Identifiestion No.
Psees No. 1 (el To5al No. Pages 4824 1
USA /4824/AF 1.(d) 1 l
- 2. PRE AMDLE l
4 2.lal This certificate is issued to satisfy Sections 173.393a 173.394,173.395, and 173.396 of the Department of Transportation Hazardout Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10s and 146.-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amendef.
2.lb) The pechseing and contents describert in item 6 below, sneets the safety standards set forth in Subpart C of Title 10 Code of I
Foferol Regulations, Pert 71, **Peckaging of Flafeosctive Matalais for Transport and Transportation of Radioactive Mater 6al Under Corteln Conditions.**
2.fc) This eartificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transpottetion or other applicable regulatory agencies, including the government of any country through or into w*wch the package will be transported.
- 3. Th'2 eertificate is issued on the basis of a safety onelysis report of the package design or applicat6on.
3.lel Properof by (Name and addres):
3.(b)
Title and identification of report or opplication:
Th] Babcock to Wilcox Company Nuclear Materials and Equipment Company i
609 North Warren Avenue application dated November 15,1966, as I
Apollo. Pennsylvania 15613 supplemented 3.fel Docket No. 71-4824
- 4. CONDITIONS This certifieste is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, es applicable, and the conditions speciflef in item 6 below.
- 6. Description of Peckagmg and Authorised Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a) Packaging (1) Model No.: HA-10 (2) Description A fissile uranium shipping container. The containment vessel is a 5-inch ID steel tube with 0.125-inch wall thickness, with a flanged, gasketed closure, and top and liottom centering plates. The containment vessel is centered within a (
12.5-inch OD steel tube with 0.0625-inch wall thickness and
)65-gallon.16-gage steel drum, built to DOT Specification '7H.
The 12.5-inch inner container is centered and supported within the 65-ga11on drum by 0.25-inch diameter spring stcol rod spacers, and thermal and mechanical insulators of vermiculite and unibestos. The total Wolght of the packaging and contents is 220 pounds.
(3) Drawings The packaging is constructed in accordance with NUMEC Drawings r
Nos.:
10 0-1210, Rev. 4; and ASK-1189-u Rev. O.
l s
(b) Contents j
(1) Type and form of material Uranium efiriched in the U-235 isotope as solid compounds.
06010906Me 770210 PDH ADOCK 0700 D
C
l.
l O
.O
'l Page 2 - Certificate No. 4824 - Revision No.1 - Docket No. 71-4824 5.
(b) Contents (continued) l I
(2) Maximum quantity of material per package Ten kilograms total contents, with the fissile content limited as follows:
i i
H/X atomic ratio U-235
(
not to exceed
_(Kg).
2.0 10.0 3.0 9.0 l
5.0 7.3 10.0 5.2 20.0 3.6 (c) Fissile Class
!! and !!!
(1) Minimum transport index to be shown on label for fissille class !!
1.9
,[
i (2) Maximum number of packages per shipment for fissile class III 49 6.
Contents as solid compunds shall provide a vapor pressure that is equal to or less than water, and the H/X ratio is not to exceed 20 based on all sources of hydrogen within the inner container.
7.
All material shall be contained within a leaktight unbreakable wlyethylene or stainless steel container within the containment vessel.
Pyrophoric materials shall be further packaged in an inert atmosphere.
8.
The package authorized by this certificate is hertby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.
9.
Expiration date:
May 31, 1980.
l l
i I
i A
.~,w
l o
o l,
1 Page 3 - Certificate No. 4824 - Revision No.1 - Docket No. 71-4824 il REFERENCES
- l Nuclear Materials and Equipment Company's application dated l
November 15, 1966.
Supplements dated: March 14, 1967; July 8, 1968; and May 9, 1975.
]
FOR Tile U.S. NUCLEAR REGULATORY COMMISSION
$N Charles E. MacDonald, Chief Transportation Branch Division of fuel Cycle and Material Safety Date rgg 3 g 1977 l
.I l
I 07198 h
I A
.