Category:NPDES NONCOMPLIANCE NOTIFICATION
MONTHYEARML20216J6651999-09-30030 September 1999 NPDES Noncompliance Notification:On 990902,harbor Seal Was Entrapped in SW Pumphouse Forebay.Seal Was Entrapped at Least Four Weeks Before Recovery.Results of Seal Necropsy Performed by New England Aquarium Encl Also ML20212F6511999-09-23023 September 1999 NPDES Noncompliance Notification:On 990821,seal Was Entrapped at Least Two to Three Weeks Prior to Recovery Which Was Before Installation of Seal Deterrent Barriers.Epa Was Also Notified Per Request ML20212B7291999-09-10010 September 1999 NPDES Noncompliance Notification:On 990811,two Seals Were Recovered.State of Decomposition Indicates That Seals Were Entrapped Prior to Installation of Seal Barriers.Results of Seal Necropsy Performed by New England Aquarium,Encl ML20211G5111999-08-24024 August 1999 NPDES Noncompliance Notification:On 990726,seal Was Entrapped at Seabrook Station.Seal Was Recovered from Screen Wash Debris on 990726.North Atlantic Notified Natl Marine Fisheries Svc & EPA of Entrapment ML20195B9771999-05-24024 May 1999 NPDES Noncompliance Notification:On 990517,seal Was Noted in Seabrook Station SW Pumphouse Forebay.Seal Will Be Provided to New England Aquarium Where Necropsy Will Be Performed ML20206A9561999-04-22022 April 1999 NPDES Noncompliance Notification:On 990407 & 08,two Seals Entrapped at Seabrook Station.Seals Were Observed in Plant Svc Water Pumphouse Forebay by Diver Involved in Cleaning of Forebay During Plant RFO ML20205D6371999-03-24024 March 1999 NPDES Noncompliance Notification:On 990310,seal Was Entrapped in Seabrooks Cw Pumphouse Forebay.Seal Has Been Provided to New England Aquarium Where Necropsy Will Be Performed ML20204J3041999-03-22022 March 1999 NPDES Noncompliance Notification:During 990220-0316, Entrapment of twenty-nine Sea Ducks Entrapped in Plant Circulating Water Cooling Sys.Cleaning of Intake Structures Scheduled to Eliminate Potential Food Source for Scoters ML20207L3671999-03-12012 March 1999 NPDES Noncompliance Notification:On 990226,seal Was Observed in Seabrook Stations Cw Pumphouse Forebay.Seal Will Be Provided to New England Aquarium Where Necropsy Will Be Performed ML20197J8471998-12-10010 December 1998 NPDES Noncompliance Notification:On 981205,discovered Seal Entrapped in Station Circulating Water Pumphouse Forebay. Seal Was Recovered on 981207 & Provided to New England Aquarium Where Necropsy Will Be Performed ML20195D6431998-11-10010 November 1998 NPDES Noncompliance Notification:On 981103,seal Was Observed & Removed from Plant Circulating Water Sys Pumphouse Forebay.During Six Days Since Previous Screen Wash on 981028,about 80 Fish Were Impinged ML20155F8961998-11-0303 November 1998 NPDES Noncompliance Notification:On 981027 Seal Skull Was Discovered.Skull Was Removed from Wash Debris & Sent to New England Aquarium in Order to Determine Species & Approx Age ML20154R6441998-10-19019 October 1998 NPDES Noncompliance Notification:On 981005 & 08,two Seals Entrapped in CWS Pumphouse Forebay & on 981010,one Seal Entrapped in CSC Screen Wash Debris.New England Aquarium Notified to Pickup Seals in Order to Perform Necropsies ML20154H4461998-10-0505 October 1998 NPDES Noncompliance Notification:On 980921,entrapment of Two Seals Occurred in CWS Pumphouse Forebay.Recovered Moderately Decomposed Seals.About Seventy Fish Were Impinged During Wk Prior to Estimated Date of Entrapment ML20151Z6251998-09-18018 September 1998 NPDES Noncompliance Notification:On 980912,observed Seal in Seabrook Station Circulating Water Sys Pumphouse Screen Wash Trench.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20237E8761998-08-27027 August 1998 NPDES Noncompliance Notification:On 980820,entrapment of Seal in Svc Water Sys Pumphouse Forebay Observed.Recovered Seal.During Wk Prior to Seal Entrapment,About 115 Fish Were Impinged ML20203C0581998-02-13013 February 1998 NPDES Noncompliance Notification:On 980211,seal Skull Discovered in Seabrook Station Circulating Water Sys Screen Wash Debris.Util Notified Natl Marine Fisheries Svc of Entrapment Incidents ML20202F3931998-02-11011 February 1998 NPDES Noncompliance Notification:On 980206,entrapment of Seal Occurred in Circulating Water Sys Pumphouse Forebay. Recovered Seal.During Wk Prior to Seal Entrapment,About 1,200 Fish Were Impinged ML20203D4911997-12-10010 December 1997 NPDES Noncompliance Notification:On 971205,seal Observed in Seabrook Station Svc Water Sys Pumphouse Forebay.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20199H2881997-11-19019 November 1997 NPDES Noncompliance Notification:On 971118,seal Entrapment Discovered.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20198P2761997-11-0303 November 1997 NPDES Noncompliance Notification:On 971018 & 20,discovered Entrapment of Two Seals at Seabrook Station.One Seal Was Observed in Seabrook Station & Second Seal Observed in Screen Wash Debris.Seals Picked Up to Perform Necropsy ML20198J8401997-10-16016 October 1997 NPDES Noncompliance Notification:On 971008 & 09,discovered Seal Trapped in Circulating Water Sys Pumphouse Forebay. Removed Seal Observed on 971009 & Did Not Recover Seal Observed on 971008.Dozen Small Fish Entrapped Previous Wk ML20198F4581997-08-0606 August 1997 NPDES Noncompliance Notification:On 970727,discovered Seal Trapped in Circulating Water Sys Screen Wash Debris.Removed Seal.Also,Approx 140 Fish Were Entrapped During Wk Prior to 970727 Entrapment Incident ML20149K1751997-07-24024 July 1997 NPDES Noncompliance Notification:On 970720,discovered Seal Entrapped in Circulating Water Sys Screen Wash Debris. Seal Removed.Also,Several Dozen Pollock & 10 Cod Were Impinged During Wk Prior to 970720 Entrapment Incident ML20141F1901997-06-24024 June 1997 NPDES Noncompliance Notification:On 970617,entrapment of Seal at Facility Occurred.Seal Appears to Be Juvenile Weighing About 50 Pounds.Seal Was Intact,But Was Partially Decayed at Time of Recovery ML20134Q0531996-11-20020 November 1996 NPDES Noncompliance Notification:On 961111-12 Unusual Number of NH0020338 Herring Impinged at Plant.Util Also Described Atlantic Herring as Often Found in Nearshore Areas ML20134M3261996-11-12012 November 1996 NPDES Noncompliance Notification:On 961101-03,an Unusual Number of Herring Were Impinged at Seabrook Station.Caused by Extremely Heavy Rains During Wk of 961020.Addl Screen Wash & Fish Impingement Assessment Conducted 1999-09-30
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20216J6651999-09-30030 September 1999 NPDES Noncompliance Notification:On 990902,harbor Seal Was Entrapped in SW Pumphouse Forebay.Seal Was Entrapped at Least Four Weeks Before Recovery.Results of Seal Necropsy Performed by New England Aquarium Encl Also ML20212F6511999-09-23023 September 1999 NPDES Noncompliance Notification:On 990821,seal Was Entrapped at Least Two to Three Weeks Prior to Recovery Which Was Before Installation of Seal Deterrent Barriers.Epa Was Also Notified Per Request ML20212B7291999-09-10010 September 1999 NPDES Noncompliance Notification:On 990811,two Seals Were Recovered.State of Decomposition Indicates That Seals Were Entrapped Prior to Installation of Seal Barriers.Results of Seal Necropsy Performed by New England Aquarium,Encl ML20211G5111999-08-24024 August 1999 NPDES Noncompliance Notification:On 990726,seal Was Entrapped at Seabrook Station.Seal Was Recovered from Screen Wash Debris on 990726.North Atlantic Notified Natl Marine Fisheries Svc & EPA of Entrapment ML20195B9771999-05-24024 May 1999 NPDES Noncompliance Notification:On 990517,seal Was Noted in Seabrook Station SW Pumphouse Forebay.Seal Will Be Provided to New England Aquarium Where Necropsy Will Be Performed ML20206A9561999-04-22022 April 1999 NPDES Noncompliance Notification:On 990407 & 08,two Seals Entrapped at Seabrook Station.Seals Were Observed in Plant Svc Water Pumphouse Forebay by Diver Involved in Cleaning of Forebay During Plant RFO ML20205D6371999-03-24024 March 1999 NPDES Noncompliance Notification:On 990310,seal Was Entrapped in Seabrooks Cw Pumphouse Forebay.Seal Has Been Provided to New England Aquarium Where Necropsy Will Be Performed ML20204J3041999-03-22022 March 1999 NPDES Noncompliance Notification:During 990220-0316, Entrapment of twenty-nine Sea Ducks Entrapped in Plant Circulating Water Cooling Sys.Cleaning of Intake Structures Scheduled to Eliminate Potential Food Source for Scoters ML20207L3671999-03-12012 March 1999 NPDES Noncompliance Notification:On 990226,seal Was Observed in Seabrook Stations Cw Pumphouse Forebay.Seal Will Be Provided to New England Aquarium Where Necropsy Will Be Performed ML20206T8391999-01-0707 January 1999 Summary of Seal Entrapment Status ML20206H5801998-12-31031 December 1998 1998 Annual Radiological Environ Operating Rept for Jan-Dec 1998 ML20206H5041998-12-31031 December 1998 1998 Annual Radioactive Effluent Release Rept for Seabrook Station ML20197J8471998-12-10010 December 1998 NPDES Noncompliance Notification:On 981205,discovered Seal Entrapped in Station Circulating Water Pumphouse Forebay. Seal Was Recovered on 981207 & Provided to New England Aquarium Where Necropsy Will Be Performed ML20195D6431998-11-10010 November 1998 NPDES Noncompliance Notification:On 981103,seal Was Observed & Removed from Plant Circulating Water Sys Pumphouse Forebay.During Six Days Since Previous Screen Wash on 981028,about 80 Fish Were Impinged ML20155F8961998-11-0303 November 1998 NPDES Noncompliance Notification:On 981027 Seal Skull Was Discovered.Skull Was Removed from Wash Debris & Sent to New England Aquarium in Order to Determine Species & Approx Age ML20154R6441998-10-19019 October 1998 NPDES Noncompliance Notification:On 981005 & 08,two Seals Entrapped in CWS Pumphouse Forebay & on 981010,one Seal Entrapped in CSC Screen Wash Debris.New England Aquarium Notified to Pickup Seals in Order to Perform Necropsies ML20154H4461998-10-0505 October 1998 NPDES Noncompliance Notification:On 980921,entrapment of Two Seals Occurred in CWS Pumphouse Forebay.Recovered Moderately Decomposed Seals.About Seventy Fish Were Impinged During Wk Prior to Estimated Date of Entrapment ML20151Z6251998-09-18018 September 1998 NPDES Noncompliance Notification:On 980912,observed Seal in Seabrook Station Circulating Water Sys Pumphouse Screen Wash Trench.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20154A5521998-09-18018 September 1998 Second Suppl to 980423 Application to Renew NPDES Permit NH0020338 for Seabrook Station.Suppl Provides Addl Info Re Proposed Outfall 025C (Waste Holdup Sump),Consisting of Attached Replacement Page to Application ML20237E8761998-08-27027 August 1998 NPDES Noncompliance Notification:On 980820,entrapment of Seal in Svc Water Sys Pumphouse Forebay Observed.Recovered Seal.During Wk Prior to Seal Entrapment,About 115 Fish Were Impinged ML20151P6001998-08-0303 August 1998 Supplemental Application for Renewal of NPDES Permit NH0020338,addressing Chemical Discharge Data for Ocean Discharge Criteria Info Rept ML20203C0581998-02-13013 February 1998 NPDES Noncompliance Notification:On 980211,seal Skull Discovered in Seabrook Station Circulating Water Sys Screen Wash Debris.Util Notified Natl Marine Fisheries Svc of Entrapment Incidents ML20202F3931998-02-11011 February 1998 NPDES Noncompliance Notification:On 980206,entrapment of Seal Occurred in Circulating Water Sys Pumphouse Forebay. Recovered Seal.During Wk Prior to Seal Entrapment,About 1,200 Fish Were Impinged ML20217Q6341997-12-31031 December 1997 Annual Radiological Environmental Operating Rept for Period Jan-Dec 1997 ML20217P2031997-12-31031 December 1997 Annual Environ Operating Rept for Jan-Dec 1997, for Seabrook Station ML20217P7891997-12-31031 December 1997 1997 Annual Radioactive Effluent Release Rept ML20206G4551997-12-31031 December 1997 1997 Environ Monitoring in Hampton - Seabrook Area. Page 4-46 of Incoming Submittal Not Included ML20203J9101997-12-31031 December 1997 1997 Annual Rept Radiation Exposure by Job Function for Seabrook Station ML20203D4911997-12-10010 December 1997 NPDES Noncompliance Notification:On 971205,seal Observed in Seabrook Station Svc Water Sys Pumphouse Forebay.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20199H2881997-11-19019 November 1997 NPDES Noncompliance Notification:On 971118,seal Entrapment Discovered.New England Aquarium Notified to Pick Up Seal in Order to Perform Necropsy in Near Future ML20198P2761997-11-0303 November 1997 NPDES Noncompliance Notification:On 971018 & 20,discovered Entrapment of Two Seals at Seabrook Station.One Seal Was Observed in Seabrook Station & Second Seal Observed in Screen Wash Debris.Seals Picked Up to Perform Necropsy ML20198J8401997-10-16016 October 1997 NPDES Noncompliance Notification:On 971008 & 09,discovered Seal Trapped in Circulating Water Sys Pumphouse Forebay. Removed Seal Observed on 971009 & Did Not Recover Seal Observed on 971008.Dozen Small Fish Entrapped Previous Wk ML20198F4581997-08-0606 August 1997 NPDES Noncompliance Notification:On 970727,discovered Seal Trapped in Circulating Water Sys Screen Wash Debris.Removed Seal.Also,Approx 140 Fish Were Entrapped During Wk Prior to 970727 Entrapment Incident ML20149K1751997-07-24024 July 1997 NPDES Noncompliance Notification:On 970720,discovered Seal Entrapped in Circulating Water Sys Screen Wash Debris. Seal Removed.Also,Several Dozen Pollock & 10 Cod Were Impinged During Wk Prior to 970720 Entrapment Incident ML20141F1901997-06-24024 June 1997 NPDES Noncompliance Notification:On 970617,entrapment of Seal at Facility Occurred.Seal Appears to Be Juvenile Weighing About 50 Pounds.Seal Was Intact,But Was Partially Decayed at Time of Recovery ML20206G4441996-12-31031 December 1996 1996 Environ Monitoring in Hampton - Seabrook Area ML20138H2761996-12-31031 December 1996 Annual Radiological Environ Operating Rept for Jan - Dec 1996 ML20138H5511996-12-31031 December 1996 Effluent & Waste Disposal Annual Rept Suppl Info 1996 ML20134Q0531996-11-20020 November 1996 NPDES Noncompliance Notification:On 961111-12 Unusual Number of NH0020338 Herring Impinged at Plant.Util Also Described Atlantic Herring as Often Found in Nearshore Areas ML20134M3261996-11-12012 November 1996 NPDES Noncompliance Notification:On 961101-03,an Unusual Number of Herring Were Impinged at Seabrook Station.Caused by Extremely Heavy Rains During Wk of 961020.Addl Screen Wash & Fish Impingement Assessment Conducted ML20138F4751996-08-31031 August 1996 Working Draft, Evaluation of Seabrook Station Phytoplankton & Chemical Nutrients Sampling Programs After Five Yrs of Plant Operation,Characterization of Environ Conditions. W/Supporting Documentation ML20138F4711996-07-31031 July 1996 1995 Environ Studies Rept Surface Panels Section ML20108A9761995-12-31031 December 1995 Annual Environ Operating Rept Jan-Dec 1995. W/ ML20138F5001995-12-31031 December 1995 1995 Environ Studies in Hampton-Seabrook Area Characterization of Environ Conditions During Operation of Seabrook Station. W/Ltrs w/encls,960422 w/encls,960530 w/encls,960301 W/Encls & Addl Dtd Ltrs ML20108D0281995-12-31031 December 1995 Effluent & Waste Disposal Annual Rept 1995 ML20107K5001995-12-31031 December 1995 Annual Radiological Environ Operating Rept for 1995 ML20100Q4971995-12-31031 December 1995 Annual Rept of Radiation Exposure by Job Function for 1995 ML20108D0451994-12-31031 December 1994 Corrected Effluent & Waste Disposal Annual Rept 1994, Table 1A ML20082R3111994-12-31031 December 1994 Annual Radiological Environ Operating Rept for Period Jan-Dec 1994 ML20082R2891994-12-31031 December 1994 Effluent & Waste Disposal Annual Rept 1994 1999-09-30
[Table view] |
Text
. _ . .. . . .
1 w,
i M
North North Atlantic Energy Service Corporation P.O. Box 300 l
Atlantic l
V seasreet. sn o3874 (603) 474-9521 The Northeast Utilities Systern j June 24,1997
]
LIC-97101 NA-970224 kr. Daniel Morris National Marine Fisheries Service i Nonheast Region One Blackbum Drive Gloucester,MA 02173 Seabrook Station Seal Entranment-June 1997 North Atlantic Energy Service Corporation (Nonh Atlantic) hereby reports the entrapment of a seal at Seabrook Station. The seal was identified in Seabrook Station's Circulating Water System on June 17,1997 and recovered the same day. North Atlantic notified the National Marine Fisheries Service of this entrapment incident by telephone'. The New England Aquarium was also notified of this seal entrapment in order to schedule a necropsy in the near future. l 3
2 This report is made in response to the National Marine Fisheries Service letter dated January 5.
~
2 1995, recommending that North Atlantic report seal entrapment incidents. The attached seal entrapment incident report is enclosed as requested.
3 On Friday, June 13, 1997, North Atlantic submitted a Small Take Exemption Pennit for the
- incidental taking of seals pursuant to Section 101(a)(5)(A) of the Marine Mammal Protection Act and in accordance with 50 CFR 216.104. The application requests a permit for the incidental taking of a small number of seals as a result of plant operations. l
' Notification of Seal Entrapment Incident, Telephone Conversation Between J. Hart (North Atlantic) and D. Morris (NMFS) on June 17,1997.
2 National Marine Fisheries Service letter dated January 5,1995, Mr. Chris Mantzaris (NMFS) to R.
Jeb DeLoach (North Atlantic).
3 North Atlantic Letter, LIC-97102,"Small Take Exemption Permit," from T. Feigenbaum (North Atlantic)to R. Schmitten (NMFS). [
9707020101 970624 PDR '
8 ADOCK 05000443 PDR lll llllllllllflll l ll
+-
. hir. Daniel Morris LIC-97101, NA-970224/Page 2 If you have additional questions, please contact Mr. Terry L. Harpster, Director of Licensing Senices, at (603) 773-7765.
I Very truly yours, NORTH ATLAN ' - GY SERVICE CORP.
- V / Afc d C. Fei[enbaInn [.
Executive Vice Pr sident and ChiefNuclear O icer
...u
'4
. Mr. Daniel Morris l . LIC-97101, NA-970224/Page 3 i
l cc (with Enclosure) l TECHNICAL ADVISORY COMMITTEE: Mr. Eric Hutchins I National Marine Fisheries Service Dr. Edward Schmidt Northeast Region NH Dept. of Environmental Services One Blackburn Drive Water Supply & Pollution Control Div. Gloucester, MA 01930 6 Hazen Drive Concord,NH 03302 NATIONAL MARINE FISHERIES l
Mr.Jeffrey Andrews SERVICE Supervisor, Industrial Permits Section Dept. of Environmental Services Mr. Daniel Morris Water Supply & Pollution Control Division National Marine Fisheries Service 6 Hazen Drive Northeast Region Concord,NH 03302 One Blackburn Drive Gloucester, MA 01930 Mr. Robert Estabrook
- NH Dept. of Environmental Services Water Supply & Pollution Control Division SEABROOK ECOLOGICAL ADVISORY 6 Hazen Drive COMMITTEE-Concord,NH 03302 Dr. John Tietjen, Chairman Mr. John Nelson 134 Palisade Avenue NH Fish and Game Department Leonia,NJ 07605 225 Main Street Durham, NH 03824 Dr. W. Huntting Howell 12 James Farm Mr. Bruce Smith Lee,NH 03824 NH Fish and Game Department 225 Main Street Dr. Saul Saila Durham,NH 03824 317 Switch Road Hope Valley, RI 02832 Mr. Frederick Gay NPDES Permit Coordinator Dr. Bernard J. McAlice New Hampshire State Program Unit HC61 Box 109 Environmental Protection Agency Round Pound,ME 04564 John F. Kennedy Building Bostc,n, MA 02203 Dr. Robert Wilce Department of Biology Mr. Jack Paar 221 Morrill Science Center l Environmental Protection Agency University of Massachusetts 60 Westview Street Amherst, MA 01003 Lexington, MA 02173
, Nir. Daniel Morris LIC-97101, NA-970224/Page 4 b
i 4
1-NORMANDEAU ASSOCIATES l Ms. Marcia Bowen I i Normandeau Associates,Inc.
l 82 Main Street Yarmouth, ME 04096 i
i Paul Geoghegan Normandeau Associates,Inc.
j 25 Nashua Road Bedford, NH 03110-5500
].
NEW ENGLAND AOUARIUM Mr. Greg Early
-New England Aquarium Resource and Rehabilitation Central Wharf Boston,MA 02910 U.S. NUCII AR REGULATORY COMMISSION U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001 Mr. A. W. De Agazio Senior Project Manager Division of Reactor Projects U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Mr. H. J. Miller Regional Administrator, Region i U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 NRC Senior Resident Inspector NAESCO PO Box 300 Seabrook,NH 03874
. i
)
e l SEABROOK STATION SEAL ENTRAPMENT INCIDENT REPORT i ONE SEAL--JUNE 17.1997 l 1
4 I
- Site of Entrapment
- Seabrook Station Circulating Water System Forebay .
i l 1
Date ofIdentification and Recovery: June 17,1997 Species Identification: Believed to be a harbor seal Description / Condition of Seals: Seal appears to be ajuvenile weighing about 50 pounds.
The seal was intact, however, it was partially decayed at the time of recovery.
Reporter: Ronald A. Sher, Senior Scientist Recent Seal Observations: One intact seal was recovered on December 31,1996. l An incident repon was submitted to the NMFS 4.
Necropsy results by the New England Aquarium showed ;
that this seal was a 150 pound adult male harbor seal in '
good health.
Recent Fish Entrapment: Limited numbers of fish were impinged at the approximate time of this seal entrapment incident.
Cooling Water Intake Temperature at Time of Entrapments: 48 F Plant Power Level at Time of Entrapment: Seabrook Station was in a refueling outage and not in l
operation. One of three circulating water pumps was operating.
l 4 North Atlantic letter NYE-97001, dated January 6,1997, " Seal Impingement-December 1996," Mr. I 5
B. Drawbridge (North Atlantic) to Mr. D Morris (NMFS) l