CERTIFICATE OF COMPLIANCE C,,., t o cra s:
accu ne s For Rad.o.cs.w Naternats Pad a,es
- ~
p
-}
t i,. R e
>o
.. iie. e m a,,too,t,t.ea -.
id ease m. e,.. ro,awa,e,1 g is.Ce,.fm eu. -
6273 0
l USA /6273/AF j
p 2, PFiE.ht33.E 2a.
This cerGf ate is issued to suisfy Sections 173333a.173 734,173.335.and 173.3'JG mf tt e O*partroeet of Tra4sportseos F.sn/dna f.'.aterials fiegw;4ns (4"A CFR f ?O.189 ard 14 CF R 3 03) med Sect'ons 146-19 104 erd 145-19 303 of it.e Otwrtmeet cf Tr.saspo rattom Daeoerous Ca.,oes ilegusat.oao 84 6 CF R 146149). as eenended.
- 23. ' The s'octiasing ard concerns dew.rit ed la itam 5 tWow, eneeto the safet y standa ds set.forth ins @, rt C of T.tre 10, Co fe a f Fadvat Rar. 2 rations.Past 21,Packab*g of Radioactive L'a erssi f or Trans:) ort and Transportat.on 6f Rad.ce.tiw Material Under Cervin Coedit sons " -
- /c.
Thes certificate does ret vel'ew the consgaar frorn comof64rtce wita any requirerrent of th,,egatat*ons of t've US. Departerent of
~
Transportat;on or r,ther asp;.a.bia segutetery yivs,includir g the sovernerwat of any country st roosh.or imo *<hich sne pec'. age veill tse trarsspoeted.
I
- 3. T his cast.ficate is Isu.d:d on ihe taasas af a safety analysis report of tFe packa-;, desiss or apotication-.
(Il Prepared try INorne sad,Jdmsl.-
(2) Title end Iderstoicati,ri of report or appt;cetiont Union Carbide Corporation Fissile Class I Shipraent of Uranium Oak Ridge Gaseous Diffusion Plant flexafluoride " Heel" Cyliners K-L-6249, Rev.1,.
P.O. Box P
. dated June 5,1974 Oak Ridge, Tennessee 37830 (3) Oncket No. 71-6273
- 4. CONCITIONS This certificite is corirbt.onal osa>n the fulfrn;ng of the requirements of sub;. art D of 13 CFR 71, as applicable,and the condit ons spec:fied i
, in e em S 5elow.
Qi Descriptmn of Pacts ging arms Authorized Corstents,Mede Nurren r, Fnsile C:sss. Other Conditic as, arms rief erences:
~
)- (a") Packaging
(
O~ -
~
.v (1) ' liedels num' ers:
5A, 8A,12A,120, 30A, 308, 48A, 4SX, 48F, and 48Y o
(2). Description Metal 5-inch, 8-inch, 12-inch, 30-inch, and 48-inch UF6 cylinders
}-
as described in Section 7, ORO-651 Rev. 3.
(b) ' Contents Type, f'orn, and maximun quantity of material per package UranlEm'hexafluoride (UF ) with a naximum U-235 enrichrtent, pounds UF
- 6 6
and U-235 content for the cylinder nodels cs follcws:
tW,01070460 741227 C\\'I PDR ADOCK 07 A04:273 Q
C PDR l
$NC /.
l
.. g
l 7
.i l
t, Page 2 - Certificate flo. 6273 - Revision flo. 0 - Docket No. 71-6273 I
- [ '
Ql 5.
(b) Contents (continued) i
. Max. Enrichment Max. UF Max. U-235' 2
6 Model fiumber w/o U-235 Pounds kas 5A 100.0 0.1 0.031 BA 12.5 0.5 0.019 6
12A,123 5.0 1.0 0.015 3DA, 308 5.0 25.0 0.333 e
48A, 48X 4.5 50.0 0.690 48F, 48Y 4.5 50.0 0.690 (c) Fissile Class 1
6.
Yalve protectors shall be provided as described in ORO-651, Rev,.3.
7.
The fabrication, assembly, testing, maintenance, and use of packagings shall be in accordance with the requirements of ORO-651, F.ev. 3.
8.
The packages authorized by this Certificate of Ccapliance are hereby approved for use under the general license previsions of Paragraph 71.12(b) of 10 CFR Part 71.
~
i 9.
Expiration date: December 31, 1979.
REFERENCE 5
(
Fissile Class I Shipeent Of tJraniun liexafluoride alleel," Cylinders, K-L-6249, Rev.1, June 5,1974.
Uranium Hexafluoride Handling Procedures and Container Criteria, OR0-651, Rev. 3, August 1972.
~
FOR THE U.S. ATONIC EtIERGY COPJilSSI0tt G/ d R./k~ U d Charles E. MacDonald, Chief Transportation Branch Directorate of Licensing Date December 20, 1974 4
[
G'
.p t
h