Text
-
GPU Nuclear Corporation Nuclear
- , oms = ~
Middletown, Pennsylvania 17057 0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Nurnber:
loril 2, 10P6 5211-86-2049 Office of Nuclear Reactor Regulation Attn. John F. Stolz, Director PWR Project Directorate No. 6 U.S. Nuclear Regul story Corrnission Washington, D. C. 20555
Dear Mr. Stolz:
Three Mile Island Huclear Station Unit 1 TMI-1)
Operating License No. OPR-50 Docket No. 50-289 Technical Specification Change Request No.116, Rev.1, Supplement II Additional InforTation on Debris Screens On December 3,1984, GPUN submitted Supplenunt II to Technical Specification Change Request No.116, Rev.1.
We cerxnitted to submit a Tech. Spec. Change Request, if necessary, to revise the purge isolation valve open position limits within a year af ter issuance of the amendment associated with Tech.
Spec. Change Request No.116, Rev.1 Artendront 109, issued May 8,1985, approved Tech. Spec. Change Request No.116, Rev.1.
We have determined that a Tech. Spec. Change Request will not be necessary.
The debris screen that is presently being designed and scheduled for installation during the Cycle 6 outage will not af f ect the open position limits of the containment purge isolation valve.
The flow area of the screen is such that during LOCA concitions, the air velocity through the screen is still well below critical limits.
Sincerely,
. D.
I kfil Director, TMI-l HDH/SM0/spb gC cc:
R. Conte 8604000264 060402 J. Thoma PDH ADOCK 05000207
'I O P
YDR 0531A GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation