Amend 141 to License NPF-49,modifying TS 3.7.14 by Clarifying Actions to Be Taken When Area Temp Exceeds Temp Limit
ML20141D525
Person / Time
Site: Millstone 
Issue date: 06/24/1997
From: Mckee P
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20141D528 List:
References
NUDOCS 9706270241
Download: ML20141D525 (4)


Text

-

Subgd UNITED STATES j

NUCLEAR REOULATORY COMMISSION l

WASHINGTON, D.C. 20665-0001 l

\\...../

NORTHEAST NUCLEAR ENERGY COMPANY. ET AL.

DOCKET NO. 50-423 1

MILLSTONE NUCLEAR POWER STATION. UNIT NO. 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.141 License No. NPF-49 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Northeast Nuclear Energy Company, et al. (the licensee) dated April 17, 1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requiremer:ts have been satisfied.

l 9706270241 970624 PDR ADOCK 05000423 P

PDR

' ~

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, 2.

and paragraph 2.C.(2) of Facility Operating License No. NPF-49 is hereby amended to read as follows:

(2)

Technical Soecifications 7

The Technical Specifications contained in Appendix A, as revised through Amendment No.

141, and the Environmental Protection Plan

,g contained in Appendix B, both of which are attached hereto are The licensee shall operate 4

hereby incorporated in the license.

the facility in accordance with the Technical Specifications and i

the Environmental Protection Plan.

j This license amendment is effective as of the date of its issuarice, to 3.

be implemented within 60 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

/

/

,f Phillip F. McKee Deputy Director for Licensing Special Projects Office Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: June 24, 1997 8

/

ATTACHMENT TO LICENSE AMENDMENT NO.141 '

FACILITY OPERATING LICENSE NO. NPF-49 DOCKET NO. 50-423 Replace the following page of the Appendix A, Technical Specifications, with the attached page. The revised page is identified by amendment number and contains vertical lines indicating the areas of change.

Remove Insert 3/4 7-32 3/4 7-32 t

4 8

/

PLANT SYSTENS i

3/4.7.14 AREA TEMPERATURE MONITORING LINITING CONDITION F0R OPERATION i

i 3.7.14 The temperature limit of each area shown in Table 3.7-6 shall not be l

exceeded.

APPLICABILITY:

Whenever the equipment in an affected area is required to be OPERABLE.

ACTION:

i With one or more areas exceeding the temperature limit (s) shown in Table 3.7-6:

a.

By less than 20*F and for less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, record the cumulative time and the amount by which the temperature in the affected area (s) l exceeded the limit (s).

i b.

By less than 20'F and for greater than or equal to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, prepare l and submit to the Commission within 30 days, pursuant to Specification 6.9.2, a Special ' Report that provides a record of the cumulative time and the amount by which the temperature in the i

affected area (s) exceeded the limit (s) and an analysis to demonstrate the continued OPERABILITY of the affected equipment.

The provisions of Specification 3.0.3 are not applicable.

l l

c.

With one or more areas exceeding the temperature limit (s) shown in l

Table 3.7-6 by greater than or equal to 20*F, prepare and submit a l l

Special Report as required by ACTION b. above and within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> i

either restore the area (s) to within the temperature limit (s) or declare the equipment in the affected area (s) inoperable.

SURVEILLANCE REQUIREMENTS 4

1 4.7.14 The temperature in each of the areas shown in Table 3.7-6 shal1 be determined to be within its limits:

i j

a.

At least once per seven days when the alarm is OPERABLE, and; l

b.

At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when the alarm is inoperable.

I i

d

)

l

/

NILLSTONE - UNIT 3 3/4 7-32 Amendment No. 77, pp. 199, 141 0511 i