, wt :
May 13, 1997 4
Mr. Donald Schnell Senior Vice President - Nuclear Union Electric Company Post Office Box 149 St. Louis, Missouri 63166
SUBJECT:
EVALUATION OF SECOND TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN REQUESTS FOR RELIEF ISI-10 AND ISI-ll FOR UNION ELECTRIC COMPANY, CALLAWAY PLANT, UNIT 1 (TAC N0. M97410)
Dear Mr. Schnell:
By letter dated December 6, 1996, Union Electric Company submitted requests for relief ISI-10 and 15I-11 for the second ten-year interval inservice inspection program plan.
The staff, with assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its review of the proposed program relief requests.
The basis for the staff's conclusions are contained in the enclosed safety evaluation.
The staff has determined that performing the ASME Code required examinations for requests for relief ISI-10 and ISI-Il are impractical for the Callaway Plant and that the licensee performed the examinations required by the Code on each of the subject welds to the extent practical.
Furthermore, the staff concluded that the licensee's examinations of the subject welds, to the extent practical, provides reasonable assurance of structural integrity.
Therefore, the staff concludes that~ pursuant to 10 CFR 50.55a(g)(6)(i), requests for relief ISI-10 and ISI-11 are authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest giving due consideration to the burden upon the licensee that could result if the requirements were imposed on the facility.
Sincerely, Original Signed By g, o{8 C g g I J g= g g y William H. Bateman, Director
'i Project Directorate IV-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket No. 50-483 DISTRIBUTION:
Enclosure:
Safety Evaluation PUBLIC' PDIV-2 Reading i
JRoe OGC, 015B18 cc w/ encl:
See next page EAdensam WJohnson, RIV WBateman PGywnn, RIV KThomas EPeyton GBagchi, ECGB TMcLellan, ECGB GHill (2)
TLH3 (SE)
DOCUMENT NAME: CAL 97410.REL MBiamonte
.,3 m
0FC PDIV-2/PM PDIV-2/LA NFIDE OGNhY PDIV-2/ b fo{
Nobas:ye EPhob kag i
M WBateb h l
NAME DATE 4/Al /97 4/m /97 4/@/97 If[/97 I/M/97 I i 0FFICIAL RECORD COPY
< nOOM 9705190262 970513 PDR ADOCK 05000483 0
PDR I
\\
l Mr. D. F. Schnell May 13, 1997 cc w/ encl:
Professional Nuclear Mr. Otto L. Maynard Consulting, Inc.
President and Chief Executive Officer 19041 Raines Drive Wolf Creek Nuclear Operating Corporation Derwood, Maryland 20855 P.O. Box 411 Burlington, Kansas 66839 Gerald Charnoff, Esq.
Thomas A. Baxter, Esq.
Mr. Dan I. Bolef, President Shaw, Pittman, Potts & Trowbridge Kay Drey, Representative 2300 N. Street, N.W.
Board of Directors Coalition Washington, D.C.
20037 for the Environment 6267 Delmar Boulevard Mr. H. D. Bono University City, Missouri 63130 Supervising Engineer, Site Licensing Mr. Lee Fritz Union Electric Company Presiding Commissioner Post Office Box 620 Callaway County Court House Fulton, Missouri 65251 10 East Fifth Street Fulton, Missouri 65151 U.S. Nuclear Regulatory Commission Resident Inspector Office Mr. Alan C. Passwater, Manager 8201 NRC Road Licensing and Fuels Steedman, Missouri 65077-1302 Union Electric Company Post Office Box 66149 Mr. G. L. Randolph, Vice President St. Louis, Missouri 63166-6149 Nuclear Operations Union Electric Company Mr. J. V. Laux, Manager P.O. Box 620 Quality Assurance Fulton, Missouri 65251 Union Electric Company Post Office Box 620 Manager - Electric Department Fulton, Missouri 65251 Missouri Public Service Commission 301 W. High Post Office Box 360 Jefferson City, Missouri 65102 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Mr. Ronald A. Kucera, Deputy Director Department of Natural Resources P.O. Box 176 j
Jefferson City, Missouri 65102 L