ML20141B596
| ML20141B596 | |
| Person / Time | |
|---|---|
| Issue date: | 05/09/1997 |
| From: | Lyons J NRC (Affiliation Not Assigned) |
| To: | Copeland R SIEMENS ENERGY & AUTOMATION, INC. |
| Shared Package | |
| ML20141B591 | List: |
| References | |
| NUDOCS 9705150350 | |
| Download: ML20141B596 (1) | |
Text
'}*'
gneeg y
i UNITED STATES
'g j
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-4001 o
May 9, 1997 Iir".*IA. Copeland Manager Siemens Power Corporation
- Nuclear Division Engineering and Manufacturing 2101 Horn Ra) ids Road
' Post Office 30x 130 Richland. WA 99352-0130-
SUBJECT:
ACCEPTANCE FOR REFERENCING OF LICENSING TOPICAL REPORT EMF-1125(P). SUPPLEMENT 1 APPENDIX C. "ANFB CRITICAL POWER CORRELATION APPLICATION FOR CO-RESIDENT FUEL"
Dear Mr. Copeland:
- We have completed our review of the subject topical report submitted by the oLSiemens Power Corporation (SPC) by letter dated November 30. 1995.
We find the report to be acceptable for referencirc in license applications to the extent specified and under the limitations delineated in the report and the associated NRC evaluation, which is enclosed. The evaluation defines the basis for acceptance of the report.
'We do not intend to reaeat our review of the matters described in the report and found acceptable w1en the re) ort appears as a reference in license a)plications. except to assure tlat the material presented is applicable to tie specific plant involved.
Our acceptance applies only to the matters described in the report.
In accordance with procedures established in NUREG-0390. it is requested that SPC publish accepted versions of this report, pro]rietary and non-proprietary.
within three months of receipt of this letter.
T1e accepted versions shall incorporate this letter and the enclosed evaluation between the title page and the abstract.
The accepted versions shall include an -A (designating accepted) following the report identification symbol.
Should our criteria or regulations change such that our conclusions as to the acceptability of the report are invalidated. SPC and/or the licensees referencing the topical report will be expected to revise and resubmit their respective documentation, or submit justification for the continued effective applicability of the topical report without revision of their respective documentation.
Sincerely.
t James E. Lyons. Acting Branch Chief Peactor Systems Branch Division of Systems Safety and Analysis Office of Nuclear Reactor Regulation
Enclosure:
-As stated 97o515o3509yoggg g derrocue ma
>