Rocketdyne Division Rockwell lnternational Corporation ROCkWell
&*"fo?n"..^;*"4:
International c mos. e.
Telex: 698478 ROCKETDYN CNPK March 31, 1986 In reply refer to 86RC04579 Mr. Harold Denton c/o PWR-B/SSPD U.S. Nuclear Regulatory Counission Washington, DC 20555
Subject:
Radiation Survey Report of the L-85 Reactor Facility Docket No. 50-375
Reference:
Rockwell International Letter 86RC03345 dated March 6, 1986, M. E. Remley to Harold Denton, " Radiation Survey Report of the L-85 Reactor Facility Following Disman-tiement and Decontamination of the Facility, Docket No. 50-375*
Dear Mr. Denton:
With our letter of March 6,1986, referenced above, we transmitted the revised radiation survey report for the L-85 nuclear examination reactor for your information and review. The report was in support of our request for a final inspection of the facility prior to voluntary termination of License Number R-118 and release of the facility for unrestricted use.
Unfortunately, the Rockwell proprietary notice was inadvertently added to the title page for the radiation survey report.
The title page has now been revised by removal of the proprietary notice and copies of the revised page are enclosed to replace those on the document sub-mitted with our letter of March 6.
If you have questions or need additional information, please call me at (818) 700-4270.
Sincer
,y ss tbof NO D K
O 75 M. E. Remley Direc/
p PDR tar Nuclear Safety and L" censing 6981A/ reg
Enclosure:
Revised title page for document N00lSRR140087, Revision A, 7 copies 0
Distribution - Page 2 i
86RC04579 March 3}, }ggg Rockwell Page 2 International cc w/ enclosure:
Mr. Frank A. Wenslawski Region V Office, NRC Mr. Joseph 0. Ward Radiologic Health Section, California Department of Health Services Mr. Kim Wong Radiation Health Unit, California Division of Operational Safety and Health
- h.."*f"d '"*
SUPPORTING DOCUMENT GONO.
S/A NO.
PAGE 1 OF TOTAL PAGES REV LTR/CHG NO NUMBER 96116
'" 5
" ' c "'
N00lSRR140087 g
g PROGR AM TITLE Decommissioning the L-85 Reactor DOCUMENT TITLE Radiation Survey for Release for Unrestricted Use - L-85 Reactor Facility DOCUMENT TYPE KEY NOUNS Safety Review Report Decontamination, Decomissioning ORIGIN AL ISSUE DATE R E L. D ATE APPROV ALS DATE n-9-se y_g _pg &
R. J. Tuttle h ioh/g PREPARED BY/DATE DEPT Mall ADDR F. E. Begley 641 T100 j
d.
' '5- ?5 M. E. Remley M
'sy d/f 7 IR&D PROGRAM 7 YESO NO O IF YES ENTER TPA NO DISTRIBUTION ABST R ACT FolloWing Cleanup of any previously detected radio-MAIL Naug activity exceeding specified limits, a radiation
- F. E. Begley (2)
T100 survey was performed throughout the L-85 reactor
- L. Bienvenue LB23 building (T093) and associated buildings (T003, T074,
- D.
E. Elliott T020 and T453).
The results of this survey show that this
- V. Keshishian LB02 facility meets the criteria established by the U.S.
- W. R. McCurnin T020 Nuclear Regulatory Comission's Regulatory Guide 1.86
- J. Mill s LB02 and NRC Dismantling Order, Docket No. 50-375, dated
- J. D. Moore T020 February 22, 1983, for release of facilitie: for
- W. Nagel LB03 unrestricted use.
- J. P. Page T006
- G. S. Poucher T034
- M. E. Remley U S LA06
- C, J. Rozas CB01
- D. A. Sheptenko T201
- V. A. Swanson T006
- R. J. Tuttle T100
- J. H. Wal ter T006
- R&NS Group (3)
Tl00