_

7 I-s'W L.--

'E ?O r.

O:lty,.,

MAR 21 W E88-SS FCTC:R'80 71-5942 Neutron Products, Inc.

ATTH: !4r. Frank Sch,toerer P.O. Box 68 Dickerson, itD 20842 Centlenen:

This refers to your application dated Novent'er 11, 1985, as anended, requesting an amendment to the Model No. 700 package.

In connection with our review, we need the infomation identified in the enclosure to this letter.

Please advise us within 30 days fran the date of this letter when this infornation will he provided. The additional information requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely.

WulSlpedby R. P. Ntpsnies Charles E.11acDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Paterial Safety, fif tSS

Enclosure:

As stated Distribution: w/ encl RH0degaarden (2)

DTHuang EPEaston 8603310158 e60321 Docket' File PDR ALGCK 07105942 C

NRC PDR PDR IE HQ Region I NMSS R/F JTCR/F-g

(

.. FCT.[ b..

.... ECIC..W............. FCIC..... '..E C.TA,

... C.TC......

JH0d6gaarden:al.

m DTHuang EPEasten CEMacDonald cgettum3 "d%[(WJ66' "d%[jf[66' "6%lNJ8$"

'63 W $$"

c5l..t&..... G

.xn >

rme ronu aie tio soi nacu o24o OFFICIAL RECORD COPY

~

Meutron Products,_Inc.

Podel No. 700 Package Docket Do. 71-5942 Enc 1 to ltr dtd:. MAR 211lll 4

imAMIMCS 1.

The liner shown on Neutron Products Drawing Ho. 240139, Rev. D is the prirary containment vessel which will contain a large cuantity (approxinately 400,000 curies) of Cobalt 60 not in special forn.

The applicant should consider the reconnendations of NUREG/CR-3019 in specifying the section and subsection of the AS"E Code applicable to drawing flotes 1.A. and 1.D. (any deviation should be justified).

t 3019 for containment relatej welds in Category I (given -in NUREG/C It is noted that the recommended welding criteria quantity of radioactive naterial 3x10 curies), is AS?'E Code Section III, Subsection NB.

2.

The reference to ASME in Notes 1.B and 1.C. should be corrected.

3.

The weld synbol for each fillet weld should specify the size of fillet weld recuired.

4.

Note 3 should be deleted. Paterial substitution by satisfying an "or equivalent" requirenent is unsatisfactory. Alternate natorials i

must be identified by a recognized specification.

STRUCTURAL i

1.

For both the top-end drop and side drop, the calculations on the retention of isolation valves have incorrectly taken credit for two

  1. 10-32 screws in the bottom of the valve body and four velds at the base of the hold-down channel. Since neither the screw nor the weld physically tie the valve body down to the lid of the liner, the loads generated by both top-end drop and side drop will not be carried by them. Calculations on the retention of isolation valves should be revised accordingly.

i 2.

It is noted that the findel No. 700 shipping cask has a diner.sional tolerance of +0.5" (GE Drawing No.129D 4770, Rev. 5). The noninal dirensions of the liner should be revised as necessary to acconnodate the dimensional variations in the !!odel No. 700 cask.

3 3.

Address the potential effects of axial thernal expansion of the aluminum sleeve on the lid closure.

4.

Address the potential ef fects of circunfrential thermal expansion of the aluninua sleeve on the cask, o

{

$ RFWAMEk j

DATE)

NRC FORM 318 (10-80) NRCM O240-OFFlCIAL RECORD COPY a