I Murr;y Selmin Vcs Presdent e

-a b

9 Consolidated Edison Company of New York, Inc.

Indian Point Station Broadway & Bleakley Ave.

Buchanan, NY 10511 Telephone (914) 737 8116 December 10, 1985 Re:

Indian Point Unit No. 2 Docket No. 50-247 Dr. Thomas E. Murley Regional Administrator U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406

Subject:

Third Supplemental Radiation Protection Oversight Committee Report.

Dear Dr. Murley:

Enclosed is the third supplemental monthly report of the Radiation Protection Oversight Committee covering its activities during the month of November 1985. We believe our commitment to ALARA and the extensive efforts we have taken to implement these principles will pay dividends during our upcoming outage. We welcome the oppor-tunity to discuss our radiological outage planning with your staff.

or the station's radiation prot /guestions regarding the committee's If you, or your staff, have any ction activities, please contact me.

Very truly yours, d b Enclosure cc:

Mr. James Taylor, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. Ronald R. Bellamy (2)

Chief, Emergency Preparedness and Radiological Protection Branch U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 38 Buchanan, NY 10511 8602030139 051210 1

PDR ADOCK 05000247 R

PDR 1.g i

t y

i

1l.

- Rg y -

r t g

Indian Point Radiation Protection Oversight Committee Report to the Vice President, Nuclear Power for November 1985 The Committee met at Indian Point on November 18, 1985. The major Committee activities included:

1.

Report f rom the Committee's Radiological Assessor 2.

Discussions with:

Richard Davisson John Goodale W.A. Homyk John O. Parry John Spivak Committee Findings and Recommendations:

1.

The Committee was impressed that each of the individuals we talked to at this meeting appears to be strongly aware of ALARA planning and his role in it, as well as the relationship between productivity and ALARA.

2.

A one day Operational / Design ALARA course has been developed and presented to Con Edison personnel from a variety of organizations which have responsibility for work related to the Indian Point Facility. The Committee commends such efforts to raise ALARA consciousness. We recommend consideration be given to the question of how high conscious-ness of ALARA principles will be assured for non-Con Edison (Contractor) personnel involved in the outage.

3.

The Committee was pleased to see the preliminary collective dose estimates for various outage tasks that have been prepared and promulgated. It'is important that throughout the outage planning and operation process there be continuing awareness by all involved of the collective dose goals.

4.

Low dose locations, suitable for use as staging and rest areas during outage operations, are being identified and established. The Committee encourages further emphasis on this aspect of outage exposure control.

Adopted by the Com.nittee, November 26, 1985.