Ack Receipt of 840810,0911 & 1102 & 19 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-456/84-05 & 50-457/84-05.Pentrameter Placement in Welds Resolved W/Acceptance of Code Case 1914
Date released: 06/02/2020 Download: ML20140D403


Responds to NRC Ltr Re Violations Noted in Insp Repts 50-456/84-04 & 50-457/84-05.Corrective Actions:Review of Spool Q6056-CV-23-6,Weld 6,Area-12 Indicates Pentrameters Not in Area of Interest
ML20140D465
Person / Time
Site: Braidwood 
Issue date: 08/10/1984
From: Farrar D
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20140D465 (13)
Responds to NRC Ltr Re Violations Noted in Insp Repts 50-456/84-05 & 50-457/84-05.Corrective Actions:Area of Incomplete Fusion Will Be Repaired & Reinspected by 841101
ML20140D441
Person / Time
Site: Braidwood 
Issue date: 09/11/1984
From: Danni Smith
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20140D441 (2)
Responds to Violations Noted in Insp Repts 50-456/84-05 & 50-457/84-05.Corrective Actions:Sensitivity of Initial Radiograph Cannot Be Questioned Due to T-hole on Properly Located Pentrameter Being Clearly Visible
ML20140D432
Person / Time
Site: Braidwood 
Issue date: 11/02/1984
From: Danni Smith
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20140D432 (3)
Responds to NRC Ltr Re Violations Noted in Insp Repts 50-456/84-05 & 50-457/84-05.Corrective Actions:Code Case 1914 Indicates Placement of Pentrameter on Weld Acceptable Providing Lead Pentrameter Numbers Not Placed on Weld
ML20140D424
Person / Time
Site: Braidwood 
Issue date: 11/19/1984
From: Danni Smith
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20140D424 (3)
Ack Receipt of 840810,0911 & 1102 & 19 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-456/84-05 & 50-457/84-05.Pentrameter Placement in Welds Resolved W/Acceptance of Code Case 1914
ML20140D397
Person / Time
Site: Braidwood 
Issue date: 12/13/1984
From: Warnick R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: REED C
COMMONWEALTH EDISON CO.
References
Download: ML20140D397 (3)