i 1

UNIVERSITY OF ATTACIBIENT I FLORIDA 9

Nuclear Reactor Facility

a:Nutarseim: cour Department ofNuclear and Radiological Engmeenng

]g51183#

Tat 052)3921429 Far (352)392-1380 M==@awmmash February 28, 1997 U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW - Suite 2900 Atlanta, CA. 30323

Dear Sir / Madam:

Re:

Facility Licreee R-56, Docket No. 50-83 In compliance.Ath our Technical Specifications reporting requirements, enclosed is one copy of the 1995-96 University of Florida Training Reactor Annual Progress Report.

This document is intended to comply with the requirements of Section 6.6.1 of the UTTR Technical Specifications.

Please advise if further information is needed.

Sincerely William G. Vernetson Director of Nuclear Facilities WGV/das Enclosure Copy: D. Cronin Sworn and subscribed this Q N day of February 1997.

(N4N d.u A Notary Public KATHLEBt A.WL90N l

w crnmannsw a a:40sses m Apt 17.1988 aanma new m., mac usamm. [l 9704180052 970317 a oppomnuyArrama., Amon heuton PDR ADOCK 05000083 P

PDR

l d

3 I

ATTACHMENT II 1995-96 Annual Progress Report Replacement Pages IV-6, IV-11 and IV-12 I

>l

.grfgr$$D / @l T

?-

1 4.

Temocrarv Zone 2 and 3 Bvoass on Fire Alarm System for Pipine Reolawment (Temporary -

Closed Item)

(Modification 95-07: Determination Completed 09 October 1995) i This 10 CFR 50.59 Determination was generated to address the temporary bypass of the Smoke Detectors in Zones 2 and 3 for piping rephement which required welding. The zones were continuously occupied during working hours and reconnected during non-working hours. This change was evaluated and determined not to involve any unreviewed safety questions. No further problems were noted.

Controlling Document:

10 CFR 50.59 Determination #95-07 1

5.

Elimination of Ouarterly Check of Air Handler Condensate for Contamintion (0-10 Surveillance) (Permanent - Closed Item)

(Modi 5 cation 95-08: Evaluation Completed 26 October 1995)

This 10 CFR 50.59 Evaluation was generated to address the discontinuation of the Q-10 surveillance which required sampling and analysis of the air handler condensate for contamination.

In a memorandum dated September 13, 1995 from the Radiation Control OfBeer to the Facility Director, the RCO recommended that sampling and analysis of the air handler condensate (Q-10 Surveillance) be discontinued. This recommendation was based on the rerouting of the air handler condensate discharge pipe to the sink in the cell which eliminated a potential unmonitored release point in January,1993 and is controlled as 10 CFR 50.59 Evaluation Number 95-08. Other data was supplied as well showirig essentially negative determinations in the sample analysis performed from August,1991 through August,1995.

The RSRS approved this change at its meeting on October 26,1995.

Controlling Document:

10 CFR 50.59 Evaluation #95-08 6.

Stack Monitor Rustrak Recorder Meter Movement Replaced and Meter Span Calibration Circuit Installation (Permanent - Closed Item)

(Modification 96-01: Evaluation Completed 14 March 1996)

This 10 CFR 50.59 Evaluation was generated to address the replacement of the failed 100 pA meter movement with a 50 pA meter movement along with a modification in the form of a linear calibration circuit to allow adjustment / calibration of the recorder meter span to keep the recorded values within the range of the recorder.

IV-6 i

i 9.

Temocrary Reolacement of Fire Alarm System Batteries (Temporary - Closed Item)

(Modification 96-04: Evaluation Completed 25 April 1996)

This 10 CFR 50.59 Evaluation was generated to address the temporary replacement of the four zone fire alarm system monitoring panel batteries with a used set of higher rated batteries, until new superior rated batteries which had been ordered could arrive and be installed, to eliminate battery trouble indications. Under MLP #96-14 and 10 CFR 50.59 Evaluation Number 96-04, the work was completed and the system tested, with no further problems noted.

Controlling Documents:

Maintenance Log Page #96-14 (Closed 18 April 1996) 10 CFR 50.59 Evaluation #96-04 10.

Eooxy Bonding ofMechanical Tachometer Adapter (Permanent - Closed Item)

(Modification 96-05: Evaluation Completed 06 June 1996)

This 10 CFR 50.59 Evaluation was generated to address the epoxy bonding of the mechanical tachometer adapterto the stack dilute fan pulley to eliminate slipping which resulted in an unreliable and decreased rpm indication in the control room.

Under 10 CFR 50.59 Evaluation Number 96-05 and MLP #96-11, a modification was approved to aflix the shaft coupling using JB Weld epoxy which was completed on 3 May 1996. Subsequently, on 7 May 1996, the lecd wires were reattached to the mechanical tachometer which was reinstalled in its bracket whereupon tubing was attached. The diluting fan was then started with no problems. The mechanical tachometer.was reading 530 rpm while the optical tach digital readout read 534 rpm which was evaluated as good. The tachometer was evaluated throughout the remainder of 7 May until late afternoon on 8 May with no problems. At this point with the mechanical tach reading 535 rpm on the control room indicator, the strobe tach was used to verify the value at 535 rpm also. MLP# 96-11 was closed with no further problems noted.

Controlling Documents:

Maintenance Log Page #96-11 (Closed 08 May 1996) 10 CFR 50.59 Evaluation #96-05 11.

Replacement of Fire Alarm System Batteries with Higher Rated Batteries (Permanent -

Closed Item)

(Modification 96-06: Evaluation Completed 08 May 1996)

This 10 CFR 50.59 Evaluation was generated to address the replacement of the fire alarm system monitoring station batteries with improved model batteries.

IV-11

l J

Previously under MLP #96-14 and 10 CFR 50.59 Evaluation Number 96-04, higher grade used batteries were placed in the fire alarm monitoring station for backup power when the regular batteries began to fail on 18 April 1996, with new batteries placed on order. The new batteries arrived on 8 May 1996. Under reopened MLP #96-14 and the new 10 CFR 50.59 Evaluat on Number 96-06, the used batteries were replaced with new higher grade 7.0 i

ampere-hour batteries with no further problems noted.

Controlling Documents:

Maintenance Log Page #96-14 (Closed 08 May 1996) 10 CFR 50.59 Evaluation #96-06 12.

Temocrary Replacement of Safety Channel 2 HVPS for Troubleshooting (Temporary -

Closed Item)

(Modification 96-07: Evaluation Completed 12 July 1996)

This 10 CFR 50.59 Evaluation was generated to address the temporary replacement of the Safety Channel 2 high voltage power supply (HVPS) with an identical supply, to be used as a variable voltage power source to allow testing of the Safety Channel 210% loss of high voltage trip circuit.

On 10 July 1996, the Quarterly Scram Checks (Q-1 Surveillance) were being performed as scheduled after last having been successfully performed on 27 March 1996. Upon performance of step 6b (Neutron Chamber High Voltage Reduction for Safety Channel 2),

Safety Channel 2 failed to effect a water drop and blade drop full trip as required when a test pushbutton was depressed simulating a 10% loss of high voltage. Because of earlier problems, this test had last been checked operable on 15 April 1996 following a series of spurious trips as discussed in an 25 april report to the NRC. Under Maintenance Log Page (MLP) #96-23, the high voltage to the detector was verified to be normal at 841.6 VDC; however, upon inspection of the resistor string which reduced the high voltage to a 4 VDC sensing circuit, a resistor was found to be intermittent. Subsequently, on 11 July 1996, the resistor was removed from the string and verified to be functional. The solderjoint to the mounting post was a cold solderjoint, limiting the contact of the resistor. However, when the resistor was correctly reinstalled, the trip circuit was still inoperative in that pushing the test pushbutton did not effect a loss-of-high-voltage trip on Safety Channel 2. Under 10 CFR 50.59 Evaluation #96-07, the Safety Channel 2 high voltage power supply (HVPS) was temporarily replaced with an identical supply, to be used as a variable voltage power source.

The voltage was then reduced until the trip occurred at 727 VDC (a 13.6% voltage drop); this value was noted to be outside the Tech Spec limit of 10% loss of high voltage to yield a trip per UFTR Technical Specifications Section 2.2(5) and Table 3.1 on Limiting Safety System Settings. At this point, the sensing circuit system was adjusted to trip at 8.6% and tested satisfactorily three times. On 12 July 1996, the circuit was again tested, but would not effect a trip unless the sensitivity of the comparator circuit was raised to 789 VDC (~6.3% voltage drop, a more conservative setting). The circuit was left at that setpoint and again tested j

satisfactorily three times.

IV-12

. _ _ _ _ _ _ _ _ _ _.