j N:rtheast 2 *d'"S"'8" " 637 Utilities System Snheut Utilitie. service company P.O. Box 270 e
Hartford, CT 06141-0270 May 30,1997 (860) 665-5000 SES-97-GN-082 D11098 DMR Processing Department of Environmental Protection Bureau of Water Management 79 Elm Street Hartford, CT 06106-5127
Reference:
Letter (C04782), NPDES Permit No. CT0003123, Haddam Neck Plant, i
Connecticut Yankee Atomic Power Company, dated September 30,1992.
Haddam Neck Plant April 1997 Monthly Discharge Monitoring Connecticut Yankee Atomic Power Company herein submits the attached report for the month of April 1997. Paragraph 4 of the NPDES Permit, Reference, requires that discharges from the permitted facility be monitored according to a specified schedule and results be reported to the Director of Water Compliance each month. Any variations from the permit are explained in the section headed "Results and Discussions" enclosed.
Additional samples that have been taken at NPDES locations and analyzed with approved methods are included in Table 2 and 3.
Should you have any questions or require further information, please all Mr. Paul Jacobson, Northeast Utilities Service Company, Environmental Services at (860) 447-1791, Extension 2335.
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY cars-S. E. 'Scace Director - Nuclear Engineering Programs y
h
\\
cc:
Mr. James Grier NRC' NRC Resident Inspector lbllbfl0lbllblfl0lNlfffllf 9706090168 970430 PDR ADOCK 05000213 R
[
DMR Processing j
D11098/SES-97-GN-082/ Enclosure /Page 1 May 3Q,1997.
I Enclosure Haddam Neck Plant Connecticut Yankee Atomic Power Comoany i
Results and Discussions l
NPDES Monthly Recon - Aoril 1997 j
l hoduction This repon fulfills the monitoring requirements for the Haddam Neck Plant (Connecticut i
Yankee), NPDES Permit No. CT0003123, dated September 30,1992. DMRs will be submitted as soon as compiled, but not later than the last day of the month following the report period as I
stated in the permit.
I l
Results and Discussions Results of the continuous, weekly and monthly monitoring programs are summarized on the DMR sheets attached. All sampling and analysis except hydrazine, ethanolamine and boron i
were conducted in accordance with EPA approved procedures set forth in EPA Publication 600/4-79-020. For these three chemical substances, CYAPCO submitted its own procedures to DEP for approval on October 4,1996.
The computerized data logging repon of the continuous monitoring program is included in Table 1. This repon is included because it provides data for the daily range of pH, temperature, i
and flow; which are required under the NPDES permit. The DMR form does not have provisions for daily ranges.
Oil Soill On April 25,1997 at 9:15 a.m., a spill of approximately one half gallon of oil was discovered in the Connecticut Yankee parking lot by plant personnel. The cause of the spill is unknown.
j Required verbal notifications were immediately made, and a written report was set to the DEP on April 30,1997 (D11066).
i DSN 001H. PCB Analvsg On April 29,1997 the semi-annual stormwater sample for DSN 00lH was collected. Of the various substances required to be monitored, only the analysis for PCB's is performed off-site.
However, due to trace amounts of radioactivity in this sample, it could not be sent off-site for PCB analysis. Another sample will be taken in the near future and the results will be included in that month's DMR. All other parameters were analyzed and are included in this report.
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Wster Management - Discharge Monitoring Report (DMR)
DATE RECEIVED (STAMPED)
Permit: CT0003123 MAJ Dist 12 Town:061 Loc:008 Facility:
CT. YANKEE ATOMIC POWER PLANT
Contact:
Paul Jacobson Town: HADDAM NECK Phone: (860) 447-1791 ext. 2335 Logged:
Delivered:
OK'd:
KEY: CT0X)3123 issue: 093092 Expire: 09/30/97 Sample Month ADnl 1997
[
Average Flow-600000000 GPD ND = none detected Discharg 0011 Mon Loc 1 NON-CONTACT COOLING WATER Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00310 100192 0/0 CP MG/L BOD 5 DAY (20 DEG C) 02/99 Code 9 00335 100192 0/0 CP MG/L CHEMICAL OXYGEN DEMAND 02/99 Code 9 01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR Last sampled 2-97 i
50050 100192 0/0 i
MGD FLOW, IN CONDUlT OR THRU 30 276 24/01 SEE ATTACHED TABLE 1 81313 100192 0/0 CP MG/L HYDRAZINE 02/99 Code 9 01051 100192 0/0 CP MG/L LEAD, TOTAL (AS PB) 02/YR Last sampled 2-97 l
01067 100192 0/0 CP MG!L NICKEL, TOTAL (AS NI) 02/YR Last sampled 2-97 00610 100192 0/0 CP MG/L NITROGEN, AMMONIA TOTAL 02/YR Last sampled 2-97 00556 100192 0/0 CP MG/L OlL & GREASE, FREON EX 02/YR Last sampled 2-97 34044 100192 0/0 G
MG/L OXIDANTS, TOTAL RESIDUAL Note 1 01/07 Note 1 No chlorine addition I
00400 100192 0/0 i
SU PH 6.4 7.0 24/01 SEE ATTACHED TABLE 1 70300 100192 0/0 CP MG/L SOLIDS, TOTAL DISSOLVED 02/YR Last sampled 2-97 COMMENTS:
Code 9 = conditional monitoring Semi-annual TSS last sampled 2-97 Note 1 = No chlorination of circ water Page 1 i
STATE OF CONNECTICUT " DEPARTMENT OF E.WIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR) l KEY: CT0003123 Issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow-600000000 GPD ND = none detected Discharg 001 1 Mon Loc: 1 NONTACT COOLING. WATER Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPENDED 5.5 17.2 01/07 2.8 17.2 1.2 3.3 2.9 38260 100192 0/0 CP MG/L SURFACTANTS (MBAS) 02/YR Last sampled 2-97 00018 100192 0/0 1
DEG TEMP DIFF BETWEEN SAMP 0.0 3.3 10.4 01/01 SEE ATTACHED TABLE 1 00011 100192 0/0 1
DEG TEMPERATURE DEG FAHR 39.6 47.8 59.6 24/01 SEE ATTACHED TABLE 1 00015 100192 0/0 CA MBTU THERMAL DISCHARGE MILL 7.4 326.5 01/30 SEE ATTACHED TABLE 1 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN) 02/YR Last sampled 2-97 COMMENTS:
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow-600000000 GPD ND = none detected Discharg 0011 Mon Loc 7 NON-CONTACT COOLING WATER Sample Weeks:
t Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
50050 100192 0/0 1
MGD FLOW, IN CONDUIT OR THRU 30 276 24/01 SEE ATTACHED TABLE 1 00011 100192 0/0 1
DEG TEMPERATURE, DEG FAHR 51.4 24/01 SEE ATTACHED TABLE 1
~
~
COMMENTS:
Page 2
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR) 1 KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow: 600000000 GPD ND = none detected Discharg 0011 Mon Loc-G NON-CONTACT COOLING WATER Sample Weeks:
1 Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR Last sampled 2-97 i
01051 100192 0/0 CP MG/L LEAD, TOTAL (AS PB) 02/YR Last sampled 2-97 01067 100192 0/0 CP MG/L NICKEL, TOTAL (AS NI) 02/YR Last sampled 2-97 02NR Last sampled 2-97 00610 100192 0/0 CP MG/L NITROGEN, AMMONIA TOTAL i
00556 100192 0/0 CP MG/L OIL & GREASE, TOTAL REC 02/YR Last sampled 2-97
~
~
70300 100192 0/0 CP MG/L SOLIDS, TOTAL DISSOLVED 02NR Last sampled 2-97 00530 100192 0/0 CP MG/L SOLIDS,TOTALSUSPENDED 02/YR Last sampled 2-97 38260 100192 0/0 CP MG/L SURFACTANTS,(MBAS) 02NR Last sampled 2-97 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN) 02/YR Last sampled 2-97 KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month April 1997 Average Flow-60000000 GPD ND = none detected Discharg 0011 Mon Loc: T NON-CONTACT COOLING WATER Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
l 02/YR Last sampled 2-97 TGA6C 100192 0/0 CP P/F P/F STAT 96 HR ACU PIMEPH TGA3D 100192 0/0 CP P/F P/F STAT 48 HR ACU D. PULEX 02/YR Last sampled 2-97 02NR Last sampled 2-97 TGC3D 100192 0/0 CP P/F P/F STAT CHR DAPHNIA P.
02NR Last sampled 2-97 TGC6C 100192 0/0 CP P/F P/F STAT CHR PIMEPHALES Page 3
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR) i KEY: CT0003123 issue: 093092 Expre. 09/30/97 Sample Month April 1997 i
Average Flouc 16000 GPD ND = none detected Discharg 001 A Mon Loc-1 STEAM ELECTRIC POWER PLANT l
Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
01022 100192 0/0 G
MG/L BORON, TOTAL (AS B) 139 02/30 130- 139 131 122 I
132. 137 127 118 00164 100192 0/0 1
GPB FLOW, GALLONS / BATCH 11875 13000 01/DS 12000 12000 12000 13000 -
7 12000 10000 12000 12000 01062 100192 0/0 G
MG/L MOLYBDENUM, TOTAL (A ND
<0.001 02/30 <.001 <.001
<.001
< 001 <.001
<.001
{
71850 100192 0/0 G
MG/L NITROGEN, NITRATE TOT ND 0.043 02/30 <.008 <.008 0.024 0.038 0.026 0.010 0.043 0.016 00615 100192 0/0 G
MG/L NITROGEN, NITRITE TOTA ND
<0.005 02/30 <.005 <.005 <.005 <.005 f
+
<.005 <.005 <.005 <,005 00556 100192 0/0 G
MG/L OIL & GREASE, FREON EX ND
<1 02/30
<1 i
i
<1 34044 100192 0/0 G
MG/L OXIDANTS, TOTAL RESIDUAL 0.19 01/07 0.17 0.19 0.16 0.15 0.16 Weekly maximums, see Table 2 00400 100192 0/0 i
SU PH 7.35 7.39 02/30 7.39 7.37
[
7.35 00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPEND ND
<1 02/30
<1 I
<1 I
i COMMENTS:
i i
I KEY: CT0003123 Issue:093092 Expre: 09/30/97 Sample Month April 1997 L
Average Flow: 120000 GPD ND = none detected
[
Discharg 001 B Mon Loc-1 BLOW DOWN FROM HEAT / COOL Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00310 100192 0/0 CP MG/L BOD 5 DAY (20 DEG C)
Code 9 02/99 l
00335 100192 0/0 CP MG/L CHEMICAL OXYGEN DEMAND Code 9 02/99 j
00940 100192 0/0 CP MG/L CHLORIDE (AS CL) 02/99 No Discharge
~
~
l COMMENTS:
Code 9 = Conditional monitoring j
i Page 4 i
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow: 120000 GPD ND = none detected Discharg 001 B Mon Loc: 1 BLOW DOWN FROM HEAT / COOL Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
~
01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 01/30 No discharge 00056 100192 0/0 T
GPD FLOW RATE. AVERAGE DAILY 24/01 No discharge 81313 100192 0/0 CP MG/L HYDRAZINE 02/99 No discharge s
01/30 No discharge 01045 100192 0/0 CP MG/L IRON, TOTAL (AS FE) l 00556 100192 0/0 G
MG/L OIL & GREASE FREON EXTR 01/30 No discharge 00400 100192 0/0 G
SU PH 01/30 No discharge 01/90 No discharge 00665 100192 0/0 CP MG/L PHOSPHORUS, TOTAL (AS P) 00530 100192 0/0 CP MG/L SOLIDS, TOTAL SUSPENDED 01/30 No discharge 00945 100192 0/0 CP MG/L SULFATE TOTAL (AS SO4) 02/99 No discharge 100192 0/0 CP MG/L ETA 01/07 No additions made COMMENTS:
Code 9 = Conditional Monitoring. Sampling only required when discharging wel lay up.
KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month April 1997 Average Flow 22000 GPD ND = none detected r
Discharg 001 E Mon Loc-1 WATER PRODUCTION WASTEWTR l
Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 0.017 01/30 0.017 C0051 42195 0/1 CP MG/L DIMETHYL AMIDE ND
<1
<1 01/30
<1 Sampled at R-18 Page 5
. = -
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow-22000 GPD ND = none detected Discharg 001 E Mon Loc-1 WATER PRODUCTION WASTEWTR
^
Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4
'5 00056 100192 0/0 T
GPD FLOW RATE. AVERAGE DAILY 2000 2000 01/30 2000 01045 100192 0/0 CP MG/L IRON, TOTAL (AS FE) 0.317 01/30 0.317 00556 100192 0/0 G
MG/L OIL & GREASE FREON EX ND
<1
<1 01/30
<1 00400 100192 0/0 l
SU PH 7.58 7.58 01/30 7.58 00665 100192 0/0 CP MG/L PHOSPHORUS, TOTAL (A ND
<0.05 01/30
<0.05 00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPENDED 3.0 3.0 01/30 3
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow: 28000 GPD ND = none detected Discharg 001 F Men Loc: 1 NON-CONTACT COOLING WATER Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
C0051 42195 0/1 CP MG/L DIMETHYL AMIDE ND
<1
<1 01/30
<1 t
Sampled at R-18 00056 100192 0/0 I
GPD FLOW RATE, AVERAGE DAILY 25900 25900 01/30 25900 00556 100192 0/0 G
MG/L OIL & GREASE FREON EX ND
<1
<1 01/30
<1 00400 100192 0/0 G
SU PH 6.65 6.65 01/30 6.65 00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPENDED 2.1 2.1 01/30 2.1 1
00011 100192 0/0 G DEG TEMPERATURE DEG FAHR 66 01/30 66 COMMENTS:
Page 6 m.
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Repod (DMR) i KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month ADril 1997 Average Flow-INTERMITT GPD ND = none detected Discharg 001 G Mon Loc 1 WATER PRODUCTION WASTEWTR Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00556 100192 0/0 G
MG/L OIL & GREASE FREON EX ND
<1
<1 02/YR
<1 39516 100192 0/0 G
MG/L PCBS-POLYCHLORINATE ND
<0.001
<0.001 02/YR
<0.001 00400 100192 0/0 G
SU PH 7.10 7.10 02/YR 7.10 KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 f
Average Flow-INTERMITT GPD ND = none detected f
Discharg 001 H Mon Loc 1 WATER PRODUCTION WASTEWTR Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 2
3 4
5 00556 100192 0/0 G
MG/L OIL & GREASE FREON EX ND
<1
<1 02/YR
<1 l
39516 100192 0/0 G
MG/L PCBS-POLYCHLORINATED 02/YR Sampled not analyzed, See ResuRs and discussson.
00400 100192 0/0 G
SU PH 7.34 7.34 92/YR 7.34 KEY: CT0003123 Issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow 22400 GPD ND = none detected Discharg 001 i Mon Loc: 1 SAN SEWAGE 20,000 - 99,000 Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
01097 100192 0/0 CP MG/L ANTIMONY, TOTAL (AS SB) 02/YR No Flow 01002 100192 0/0 CP MG/L ARSENIC, TOTAL (AS AS) 02/YR No Flow 02/YR No Flow 00998 100192 0/0 CP MG/L BERYLLIUM TOTAL (AS BE)
COMMENTS:
Page 7
~.
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)
KEY: CT0003123 issue: 093092 Expire: 09r3P97 Sample Month April 1997 Average Flow-22400 GPD ND = none detected Discharg 001 i Mon Loc: 1 SAN SEWAGE 20,000 - 99,000
~
Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00310 100192 0/0 G
MG/L BOD 5 DAY (20 DEG C) 04/30 No Flow 01027 100192 0/0 CP MG/L CADMlUM, TOTAL (AS CD) 02/YR No Flow 01032 100192 0/0 G
MG/L CHROMlUM, HEXAVALENT 02/YR No Flow i
01034 100192 0/0 CP MG/L CHROMlUM, TOTAL (AS CR) 02/YR No Flow 01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR No Flow 00722 100192 0/0 G
MG/L CYANIDE, FREE (AMEN. TO 02/YR No Flow 00720 100192 0/0 G
MG/L CYANIDE TOTAL (AS CN) 02NR No Flow 00056 100192 0/0 T
GPD FLOW RATE, AVERAGE DAILY 01/01 No Flow 01051 100192 0/0 CP MG/L LEAD, TOTAL (AS PB) 02/YR No Flow 71900 100192 0/0 CP MG/L MERCURY, TOTAL (AS HG) 02/YR No Flow 01067 100192 0/0 CP MG/L NICKEL, TOTAL (AS NI) 02NR No Flow 05/07 No Flow 00300 100192 0/0 G
MG/L OXYGEN, DISSOLVED (DO) 00400 100192 0/0 G
SU PH 05/07 No Flow 46000 100192 0/0 CP MG/L PHENOLS 02NR No Flow 01147 100192 0/0 CP MG/L SELENIUM, TOTAL (AS SE) 02NR No Flow 01077 100192 0/0 CP MG/L SILVER, TOTAL (AS AG) 02NR No Flow 00545 100192 0/0 G
MG/L SOLIDS, SETTLEABLE 05/07 No Flow Page 8
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR) i KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month April 1997 Average Flow-22400 GPD ND = none detected Discharg 001 i Mon Loc-1 SAN SEWAGE 20,000 - 99,000 Sample Weeks:
Code Start s/m Typ _ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPENDED 04/30 No Flow 00011 100192 0/0 G DEG TEMPERATURE, DEG FAHR 05/07 No Flow 01059 100192 0/0 CP MG/L THALLIUM, TOTAL (AS TL) 02/YR No Flow 00070 100192 0/0 G
NTU TURBIDITY 05/07 No Flow 02/YR No Flow 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN)
COMMENTS:
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 I
Average Flow-22400 GPD ND = none detected Discharg 001 i Mon Loc-G SAN SEWAGE 20,000 - 99,000 l
Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
04/30 No Flow
[
00310 100192 0/0 G
MG/L BOD 5 DAY (20 DEG F) 00400 100192 0/0 G
SU PH 04/30 No Flow T
05/07 No Flow 00545 10092 0/0 G
MG/L SOLIDS, SETTLEABLE 04/30 No Flow 00530 10092 0/0 G
MG/L SOLIDS, TOTAL SUSPENDED COMMENTS:
t L
Page 9
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)
KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month April 1997 Average Flow: 22400 GPD ND = none detected Discharg 001 i Mon Loc: K SAN SEWAGE 20,000 - 99,000 Sample Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
{
01/30 No Flow 81010 100192 0/0 CA
% BOD, 5-DAY PERCENT REMOV 01/30 No Flow 81011 100192 0/0 CA
% SOLIDS, SUSPENDED PERCEN COMMENTS:
KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month April 1997 Average Flow 10000 GPD ND = none detected Discharg 001 J Mon Loc: 1 BLOW DOWN FROM HEAT / COOL S ~ 's Weeks:
Code Start s/m Typ Unit Parameter Min.
Ave.
Max.
Freq 1
2 3
4 5
00056 100192 0/0 T
GPD FLOW RATE, AVERAGE DAILY 500 02/99 500 500 500 500 500 81313 100192 0/0 G
MG/L HYDRAZINE 32.000 01/90 12.00 32.00 32.00 10.40 0.04 Weekly Highs only, see Table 3 00610 100192 0/0 G
MG/L NITROGEN AMMONIATOTAL 100.200 01/90 45.0 46.2 100.2 63.9 0.3 Weekly Highs only, see Table 3 00556 100192 0/0 G
MG/L OIL & GREASE FREON EXTR 01/90 Last sampled 3/97 i
00400 100192 0/0 I
SU PH 7.87 9.27 01/90 9.18 9.27 9.01 8.72 7.87 Weekly Highs only, see Table 3 00530 100192 0/0 G
MG/L SOLIDS, TOTAL SUSPEND ND
<1
<1 01/90
<1
<1
<1
<1 COMMENTS:
Page 10
STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management -Discharge Monitoring Report (DMR)
PERMIT:CT0003123 DIST:12 TOWN: 061 LOC: 008 FACILITY:
CT. YANKEE ATOMIC POWER PLANT MAILING NAME:
CT. YANKEE ATOMIC POWER CO. ~
ADDRESS: INJUN HOLLOW ROAD ADDRESS:
P.O. BOX 270 CITY, STATE, ZIP: HADDAM NECK, CT CITY, STATE, ZIP:
HARTFORD, CT 06141 CONTACT:
MR. PAUL JACOBSON CONTACT:
MR. PAUL JACOBSON PHONE: 860-447-1791 Ext. 2335 PHONE:
860-447-1791 Ext. 2335 If there are any changes or corrections with your facility information, please cross out incorrect information and replace with correct information.
THIS DMR CONSISTS OF 11 PAGES FOR THE REPORTING PERIOD April 1997 STATEMENT OF AOKNOWLEDGEMENT i
t I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properiy gather and evaluate the information submitted. Based on my inquiry of the prson or persons i
who manage the system, or those persons directly responsible for pathering the information, the information submitted is, to the best of my know-ledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possi-bility of fine and imprisonment for knowing violations.
Authorized Official:
S. E. Scace
Title:
Director-Nuclear Engineering Programs i
Signature:
rd&
Date:
( t/[
/
/
l Page 11
TABLE 1. Paga 1
' CONN YANKEE $TATION MONTNLY WATER QUALITY DATA StpetARY / DISCHARGE SERIAL NLMBER 001 1
DATA PERIOD = 1 APR 97/0000 - 30 APR 97/2345 DATA ACQUISITION INTERVAL = MINUTES 00-15 OF EACM NOUR DAY PN RANGE FLOW RANGE CIRC PU w MAX MIM AVG SDEV MAX MIN AVG SDEV MAX NL MIN HL AVG ML SD HL MRC HL MAX MIN AVG MAX MIN TER TEMP TEW TEMP DEL T DEL T DEL T DEL T 1
7.0- 6.8 186 0 37 1
0 41.2 39.6 40.3 0.5 2.6 0.2 0.9 0.8 54.4 0.0 5.1 10.5
-16.8 2
6.9-6.8 6
0 0
0 0 43.3 40.2 41.7 1.2 3.9 2.4 3.0 0.5 7.5 0.0 0.3 1.5
-7.5 3
6.8-6.6 0
0 0
0 0 46.0 42.2 43.9 1.4 5.4 3.9 4.6 0.5 0.0 0.0 0.0 0.0 0.0 4
6.8-6.6 0
0 0
0 0 46.6 44.1 45.3 0.9 4.8 3.4 4.1 0.4 0.0 0.0 0.0 0.0 0.0 5
6.9-6.6 192 0 48 2
0 50.2 43.7 46.4 2.1 5.9 0.0 3.4 1.7 232.5 0.0 23.2 48.6 219.2 6
6.9-6.8 192 6 67 2
0 45.2 43.6 44.3 0.6 1.4 0.0 0.5 0.6 10.6 0.0 2.3 2.3
-10.4 7
6.8-6.6 6
6 6
0 0 52.7 45.1 48.0 2.3 7.3 1.1 3.4 1.8 22.0 3.5 10.2 5.4 4.9 8
6.8-6.5 192 6 33 2
0 48.5 43.9 46.9 1.2 3.6 0.2 2.3 0.8 177.6 5.8 19.5 37.9 167.8 I
9 7.0- 6.8 192 0 137 2
0 44.1 43.0 43.5 0.4 0.5 0.0 0.2 0.1 34.6 0.0 9.1 11.0
-14.8 10 6.9-6.8 0
0 0
0 0 45.0 42.4 43.6 1.0 2.8 0.7 1.6 0.9 0.0 0.0 0.0 0.0 0.0 11 6.8-6.7 0
0 0
0 0 48.0 43.8 45.5 1.4 5.3 2.5 3.6 0.9 0.0 0.0 0.0 0.0 0.0 12 6.8-6.6 0
0 0
0 0 47.9 45.3 46.4 0.8 5.2 3.7 4.2 0.4 0.0 0.0 0.0 0.0 0.0 13 6.7-6.6 0
0 0
0 0 49.7 46.9 48.0 0.9 6.4 4.5 5.1 0.5 0.0 0.0 0.0 0.0 0.0 14 6.7-6.6 0
0 0
0 0 48.8 46.5 47.6 0.8 4.9 3.3 4.1 0.4 0.0 0.0 0.0 0.0 0.0 15 6.7-6.6 3
0 0
0 0 50.9 47.1 48.7 1.3 5.5 4.2 4.9 0.4 8.4 0.0 0.4 1.7
-8.4 16 6.8-6.6 192 0 28 2
0 52.0 45.4 49.3 2.1 6.6 0.0 4.5 1.7 326.5 0.0 17.1 67.0 326.5 17 6.8-6.7 186 6 64 1
0 48.4 45.0 46.4 1.1 2.2 0.0 0.5 0.6 9.2 0.0 2.0 2.3
-9.2 18 6.8-6.7 6
6 6
0 0 48.4 46.8 47.5 0.5 2.3 1.1 1.6 0.4 7.1 3.3 4.9 1.3
-0.8 19 6.7-6.6 6
6 6
0 0 47.7 ~ 46.8 47.1 0.3 2.7 1.4 2.1 0.4 8.2 4.3 6.3 1.3 0.8 20 6.7-6.6 6
6 6
0 0 50.6 47.0 48.6 1.4 5.4 2.8 3.9 0.9 16.3 8.4 11.7 2.6
-2.8 21 6.6-6.5 6
6 6
0 0 54.0 47.5 49.8 2.2 9.3 3.5 5.4 1.9 27.9 10.6 16.4 5.7 8.9 22 6.6-6.5 6
6 6
0 0 55.8 47.9 50.4 2.1 10.4 4.2 5.8 1.5 31.4 12.7 17.6 4.4 15.8 23 6.6-6.5 6
6 6
0 0 54.1 49.9 51.4 1.2 8.1 4.5 5.6 0.9 24.3 13.6 17.0 2.6
-5.8 25 6.8-6.4 192 6 89 2
0 50.6 46.6 48.9 1.7 4.6 0.0 2.4 2.0 276.2 0.0 26.1 62.3 265.9 25 6.7-6.5 186 0 62 1
0 49.9 46.6 48.0 1.2 2.0 0.0 0.7 0.7 3.2 0.0 0.2 0.7
-3.2 26 6.6-6.4 3
0 0
0 0 51.9 48.0 50.0 1.5 2.7 0.9 1.9 0.6 2.7 0.0 0.1 0.6
-2.7 27 6.5-6.4 0
0 0
0 0 57.5 49.6 53.4 3.1 7.4 2.1 4.6 2.2 0.0 0.0 0.0 0.0 0.0 28 6.5-6.4 6
0 3
0 0 55.0 52.8 53.8 0.5 6.2 4.3 5.1 0.6 14.6 0.0 6.3 7.0 14.6 29 6.6-6.4 6
0 5
0 0 55.6 51.5 53.3 1.4 5.0 3.5 4.1 0.5 15.1 0.0 11.0 4.4
-11.2 30 6.6-6.5 8
6 6
0 0 59.6 52.6 55.5 2.3 8.9 3.8 5.4 1.6 26.8 11.4 16.6 4.7 7.9 MON 7.0- 6.4 192 0 21 2
0 59.6 39.6 47.8 3.8 10.4 0.0 3.3 2.0 326.5 0.0 7.4 21.7 326.5 PN RANGE = LOWEST AND MIGHEST PM AT DISCHARGE CANAL (PN UNITS)
FLOW RANGE = LOWEST AND HIGNEST FLOW FROM DISCHARGE CANAL (10**3 GAL / MIN)
CIRC PUMP = LOWEST AND HIGNEST WlMBER OF CIRC PLMPS OPERATING MAX TEMP = MAXIMUM TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)
MIN TEMP = MINIMUM TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)
AVG TEMP = AVERAGE TEMPERATURE AT DISCHARGE STRUCTURE (DEG F) i SDEV TEMP = STANDARD DEVIATION OF TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)
MAK DEL T = MAXIMUM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)
MIN DEL T = MINIMUM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F) l AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)
SDEV DEL T = STANDARD DEVIATION OF TEWERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)
. MAX NL = MAXIMUM MEAT LOAD OF DISCHARGE WATER (10**6 BTU /NR)
KIN ML = MINIMUM HEAT LOAD OF DISCHARGE WATER (10**6 STU/NR)
AVG ML = AVERAGE HEAT LOAD OF DISCHARGE WATER (10**6 BTU /NR)
SD CL = STANDARD DEVIATION OF MEAT LOAD OF DISCHARGE WATER (10**6 BTU /NR)
MRC NL = MAXIMtm RATE OF CHANGE OF MEAT LOAD (NL FOR QUARTER NOUR T MINUS NL FOR QUARTER NOUR T-1/ QUARTER HOUR) (10**6 STU/NR**2)
TABLE 1, Page 2 CONN Y -
ANKEE STATION MONTMLY WATC QUALITY DATA SUBetARY / DISCMARGE SERIAL NLSSER 001 r
EXCEPTION REPORT FOR MAX 19RJM TEMPERATURE DIFFERENCE FRON INTAKE STRUCTURE TO DISCHARGE CANAL GREATER THAN 38 DEG F NOME EXCEPTION REPORT FOR MAXIMUM DISCHARGE TEMPERATURE AT DISCHARGE CANAL GREATER THAN 121 DEG F NONE EXCEPTION REPORT FOR PM AT DISCNARGE CANAL LESS THAN 6.0 OR GREATER THAN 9.0 PH UNITS NOME l
i i
i i
E
.a~.
..i-.m
.. _ _ _ -. ~
W TABLE 2 April 1997 Additional TRO Analysis for DSN 001 A. in ma/L Week 1 Week 2 Week 3 Week 4 Week 5 0.13 0.08 0.09 0.10 0.16 0.02 0.09 0.06 0.15 0.08 0.14 0.07 0.06 0.11 0.11 0.05 0.11 0.14 0.08 0.04 0.05 0.19 0.16 0.09 0.06 0.03 0.17 0.10 0.08 0.08 i
0.17 0.15 0.12 0.10 0.09 0.06 0.07 0.01 0.02 0.06 0.08 0.03 0.03 0.02 0.01 0.10 0.10 l
1
TABLE 3 April 1997 Connecticut Yankee additional data (in mell)
DSN 001J Date Hydrazine Ammonia TSS pH Boder B Boder A Boder B Boder A Boder B Boder A Boder B Boder A 4/1/97 8.500 shut down 25.200 shut down shut down 9.02 shut down 4/2/97 11.900 34.000 9.11 4/3/97 10.800 45.000 9.18 4/4/97 12.000 38.000 9.06 4/7/97 5.000 15.970
<1 9.21 4/8/97 6.400 43.000 8.70 4/9/97 10.800 40.060 8.80 4/10/97 13.000 46.180 8.98 4/11/97 32.000 45.230 9.27 4/14/97 32.000 69.000
<1 9.01 4/15/97 10.800 44.000 8.87 4/16/97 7.800 51.400 8.79 4/17/97 10.600 100.200 8.97 4/18/97 8.800 93.400 8.87 4/21/97 10.400 10.340
<1 8.53 4/22/97 4.500 7.360 8.53 4/23/97 5.600 30.675 8.60 4/24/97 5.900 63.900 8.59 4/25/97 5.100 23.205 8.72 4/30/97 0.035 0.258
<1 7.87 l
+
=
.