RC-97-0063, TS Change Request - TSP 97-02 to License NPF-12,charging mini-flow Header Isolation Motor Operated Valves

From kanterella
(Redirected from ML20140C098)
Jump to navigation Jump to search

TS Change Request - TSP 97-02 to License NPF-12,charging mini-flow Header Isolation Motor Operated Valves
ML20140C098
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 03/26/1997
From: Gabe Taylor
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Andrea Johnson
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20140C102 List:
References
RC-97-0063, RC-97-63, TAC-M93779, NUDOCS 9704020074
Download: ML20140C098 (3)


Text

,

south Carolina Electric & Gas Company Gary J. Taylor P.o. Box 88 Vic3 PrIsident Jenkinsvine. sC 29065 Nuclear operations (803) 345-4344 SCE&G March 26,1997 RC-97-0063 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 1

I Attention:

Mr. A. R. Johnson 1

Gentlemen:

Subject:

VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50/395 CPERATING LICENSE NO. NPF-12 TECHNICAL SPECIFICATION CHANGE REQUEST - TSP 970002 ECCS CHARGING /HHSI PUMP CROSS CONNECT AND MINI-FLOW HEADER ISOLATION MOTOR OPERATED VALVES

Reference:

Mr. Stephen Dembek (NRC) to Mr. Gary J. Taylor (SCE&G) letter dated January 3,1996 (TAC NO. M93779)

South Carolina Electric & Gas Company (SCE&G), acting for itself and as agent for South Carolina Public Service Authority, hereby requests an amendment to the Virgil C.

Summer Nuclear Station (VCSNS) Technical Specifications (TS). This request is being submitted pursuant to 10 CFR 50.90.

In an NRC letter from Mr. Stephen Dembek (NRC) to Mr. G. J. Taylor (SCE&G), dated January 3,1996, the NRC required the charging /HHSI pump cross-connect valves (XVG-8133A and XVG-8133B) to meet the recommendations of BTP ElCSB 18. In response to the NRC letter, SCE&G will perform modifications to XVG-8133A and XVG-8133B during the VCSNS tenth refueling outage to meet the recommendations of the BTP. This includes the attached Technical Specification change request (TSCR) to add XVG-8133A and XVG-81338 to Surveillance Requirement 4.5.2.a.

The attached TSCR also includes the addition of the charging mini-flow header isolation valve (XVG-8106) to Surveillance Requirement 4.5.2.a. This proposed change is an administrative change to meet the recommendations of BTP ElCSB 18 which requires the Technical Specifications include a list and the required positions of manually-controlled, electrically operated valves to which the requirements for removal of electrical power is applied in order to satisfy the single failure criterion. XVG-8106 already meets the other requirements of BTP-EICSB 18.

Surveillance Requirement 4.5.2.a will require XVG-8133A, XVG-81338, and XVG 8106 to be verified, in the open position with power to the valve operators removed, once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

I 9704020074 970326 DR ADOCK 0500 5

(

M.UU.0,@

Document Control Desk TSP 970002 a

RC-97-0063

' Page 2 of 3 The TSCR is contained in the following attachments:

i Attachment i Explanation of Changes Summary Marked-up Technical Specification Pages Revised Technical Specification Pages 1 Safety Evaluation 11 No Significant Hazards Evaluation SCE&G requests NRC review and approval of this amendment request prior to the tenth refueling outage which is scheduled to begin on October 4,1997.

This proposed amendment has been reviewed and approved by the Plant Safety Review Committee and the Nuclear Safety Review Committee.

l These statements and matters set forth herein are true and correct to the best of my i

knowledge, information, and belief.

Should you have questions, please call Mr. Jim Proper at (803) 345-4088.

{

j V

trul rs, Gary r

CED/GJT/dr Attachments (3) c:

J. L. Skolds W. F. Conway R. R. Mahan (w/o Attachments)

R. J. White L. A. Reyes NRC Resident inspector J. B. Knotts Jr.

M. K. Batavia K. R. Jackson RTS (TSP 970002)

File (813.20)

DMS (RC-97-0063)

NUCLEAR EXCELLENCE - A SUMMER TRADITION!

Document Control Disk TSP 970002 RC-97 0063 Page 3 of 3 STATE OF SOUTH CAROLINA :

TO WIT :

COUNTY OF FAIRFIELD I hereby certify that on the 26 day of /bA 19 97. before me, the subscriber, a Notary Public of the State of South Carolina, personally appeared Gary J.

Taylor, being duly sworn, and states that he is Vice President, Nuclear Operations of the South Carolina Electric & Gas Company, a corporation of the State of South Carolina, that he provides the foregoing response for the purposes therein set forth, that the statements made are true and correct to the best of his knowledge, information, and belief, and that he was authorized to provide the response on behalf of said Corporation.

WITNESS my Hand and Notarial Seal

/

[MI N%.

Notaf5 Public f

My Comr' ission Expires I'y ComdsionExphsJufy13,2005 n

~

Date i

NUCLEAR EXCELLENCE - A SUMMER TRADITIONI

..