Advises That Safety/Relief Valve Lift Indicating Switch Assembly Device Satisfies Requirements of NUREG-0588, Category Ii.Environ Qualification Test Rept & Review Contained in Facility Binder EQ LS083
ML20140B547
Person / Time
Site: LaSalle  
Issue date: 03/20/1986
From: Allen C
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0588, RTR-NUREG-588 1450K, NUDOCS 8603240226
Download: ML20140B547 (1)


Text

___ _ ____ - _

'^N Commonwe:lth Edison i,) One First National Plaza. Chicago, litenois

.\\v J Address Reply to. Post Office Box 767 Chicago. Illinois 60690 March 20, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

LaSalle County Station Units 1 and 2 Direct Indication of Safety / Relief Valve Position NRC Docket Nos. 50-373 and 50-374 References (a): NPF-11 License Condition 2.C.(30).(g).

(II.D.3. SER, SSER #2)

(b):

LaSalle EQ Binder No. EQ LS083

Dear Mr. Denton:

Unit 1 License Condition 2.C.

(30).g required the station to replace the existing SRV position indicator with a model that meets the requirements of IEEE 323-1974 and 344-1975 prior to startup after the first refueling outage.

The lift indicating switch assembly (LISA) on the SRV's has been successfully tested by Crosby per an approved test procedure. Based on the test results, Commonwealth Edison has concluded that the SRV LISA device satisfies the requirements of NUREG-0588, Category II.

The environmental qualification test report and review of this document are contained in reference 2.

Since the existing SRV position indicators have been qualified to the requirements of IEEE 344-1975 and the intent of IEEE 323-1974, we believe that this license condition has been saticfied and will continue operation with these indicators installed.

If you have any further questions regarding this matter, please contact this office.

One signed original and ten (10) copies of this transmittal and its attachment are provided for your use.

Very truly yours, N

C. M. Allen Nuclear Licensing Administrator cc: Region III - Inspector - LSCS 0!

A. Bournia - NRR 0

I 1450K B603240226 860320 PDR ADOCK 05000373 p