.._
D ses s
UNION ELECTRIC N December 23, 1985 1901 Grotiot Street St Louis DonokiF. Schnell j
Vke Rekkd Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 j
Dear Mr. Denton:
ULNRC-1230 DOCKET NUMBER 50-483 CALLAWAY PLANT, UNIT 1 REVISION TO TECHNICAL SPECIFICATION FIGURES 3.9-1, 5.6-1 i
AND SECTIONS 3/4 9.12, 5.3, 5.6 CONCERNING SPENT FUEL POOL STORAGE Ref:
ULNRC-1192 dated October 15, 1985 In a recent review of the referenced submittal, we have detected an error in the dose calculations contained on page 6 of 7 of Enclosure 1 for a dropped assembly in the fuel building.
The assembly iodine and noble gas inventories taken from Table 15.7-2 of WCAP-9500 and used in the calculation were found to be incorrect.
In discussions with Westinghouse, we have determined that the change from Westinghouse Standard Fuel to Westinghouse Optimized Fuel Assemblies does not change the source term used in a dropped assembly analysis; and therefore, the evaluation currently contained in Section 15.7.4 of the Callaway FSAR remains valid.
The results remain well below 10CFR100 criteria and additionally well below the guidelines given in the Standard j
Review Plan Section 15.7.4.
We have reviewed the Safety Evaluation and the Significant i
Hazarda Consideration contained in the referenced letter and found that the conclusions have not changed.
We-have also I
reviewed the November 6, 1985 Federal Register notice associated l
with this amendment request.
The discussion contained therein remains applicable and requires no revision as a result of this j.
letter.
In conclusion, the proposed Technical Specification l
changes do not adversely affect or endanger the health or the safety of the general public, and do not involve an unreviewed safety question or present a significant hazard.
Very truly yours,
$$k23gDO
[3
/
P i
Do ld F. Schnell e
NGS/lw i
A0 = J. BNtCNT (ILP enly) 1 M '. as tsatumet Molkng Address PQ Sou M St Louis MO 63166 l
a
{
p$3 lStnLINGERl MB.
EG D
w STATE OF MISSOURI )
)
Robert J.
Schukai, of lawful age, being first duly sworn upon oath says that he is General Manager-Engineering (Nuclear) for Union Electric Company; that he has read the foregoing document and knows the content thereof; that he has executed the same for and on behalf of said company with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.
7 By Robert bchukai G
Manager-Engincering Nuclear SUBSCRIBED and sworn to before me this 834Iday of had,19g Mn 0 Phi)
V U0 BARDA3A J. PFAFF NOTARY FCOLfC. STATE OF f.?!SFCUffl MY COMMISS101 EXPIMS t.P21L 22, ISG3 ST. LOU!O CCU JY A
9
t cc:
Gerald Charnoff, Esq.
Shaw, Pittman, Potts & Trowbridge 1800 M.
- Street, N.W.
Washington, D.C.
20036 Nicholas A.
Petrick Executive Director SNUPPS 5 Choke Cherry Road Rockville, Maryland 20850 C.
W.
Hehl Division of Projects and Resident Programs, Chief, Section lA U.S.
Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Bruce Little Callaway Resident Office U.S.
Nuclear Regulatory Commission RRil Steedman, Missouri 65077 Tom Alexion Office of Nuclear Reactor Regulation U.S.
Nuclear Regulatory Commission Mail Stop P-316 7920 Norfolk Avenue 3ethesda, MD 20014 l
.