.x l

ILLINOIS INSTITUTE OF TECHNOLOGY Lewis College of Science and Letters Department of Mathematics October 25, 1985 Mr. J. Keppler, Regional Administrator, US NRC, Region III 733 Ruo:evelt Rd.

Glen Ellyn, Illinois

Dear Mr. Keppler:

I am enclosing a copy of my letter to Mr. F. Maura. As stated at the meeting, the fraudulent computer programs can be used for determining the conservative values of the test parameters. I promised to assist Mr. Maura in conducting such analysis. I shall be available on Tuesdays and Thursdays.

I appreciate attempts to straighten the Zion test situation and to establis the estimate of leak rate which would nct require, if close to legal limits the retesting of the containment system.

Sincerely,

[

I

' *]

Z. ReytblattM 0512300412 851025 DR ADOCK 050 5

l l

LIT Center Chicago, Illinois 60616 (312) 567 3162 L