y.

-r g

Allied Corporation PO Dax430 RETURN TO 396-SS ABX

str =

Tele s.^0430 7 N

a October 15, 1985 NN Certified P-557-921-203

~3 N

~

Mr. Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. MacDonald:

SUBJECT:

Docket 71-6273 This letter is Allied Corporation's request that the existing Certificate of Compliance No. 6273 for the Model No. 48A, 48X, 48F, and 48Y cylinders be renewed.

Allied Corporation also requests that the Certificate of Com-pliance be issued to:

Allied Corporation Chemical Sector P. O. Box 430 Metropolis, Illinois 62960 The change in Corporate identity is solely due to corporate reorganization.

Allied Corporation will use this package for shipping natural uranium, as uranium hexafluoride, from its Metropolis Plant, License No., SUB-526, Docket 40-3392.

Sincerely, j

C. a %

^ Mi%gM2KK:::::::'

A. J. Cipolla ppec;penfjp~[#/ M.ygg Q

d Plant Manager E

Cha-h R"'d. /p uf m

t'9 g

!?,

bjs.

s

--gOCO5VCdlly F

n e

7 mql gz N B 'm y

s s

,,, o a

6_-

2.4 E

9 S'*

a a

t10V 6 sBS '

w e

[Ss k E 8)]

E nun 5

M Ailstcit0%

3

/

P po y.Eltitax s-l

~

[

ndv. % + rem jobeks-

Form NRC418 U.S. NUCLEAR REGULATORY Commission

,g g;721, CERTIFICATE OF COMPl. LANCE n2 g7 For Renicactive Meierleis Pecteens 1.te) Certiteete Nwneer 1.lbi Romeiea No.

1.f ti Pockoos identification No.

1.14) Peees No, t.len Total No. Peees 6273 4

USA /6273/AF 1

3

2. PREAMBLs 2.tel This certificate is inewed to notisfy Secteas 173.303a.173,394,173.396. and 173.394 of the C=1;.;,c.t of Treassortetea Hesordous Meierials Requietions (49 CFR 170129 and 14 CPR 1031 and Sections 146-19-10e one 146-19-100 of the ossertment of Treasoortetson Deagerous Cargoes Reevieteas 144 cPR I AG-149), as amended.

2.iel The secteeg and eenients oeserobed 6n item I below, meets the seiety sienseres set forin in Suceert C of Tide 10. Coos of i

Fedeces Reewletons. Part 71, **Packageag of Rafeestive 6Aeterials for Trenesert and Treassorietea of Renicestive Meteriel Unser Carte.a Coaeriens."

(

2.lc)

This seri r.cose see, not reie.e the cone.eaer from someaienee with eay reevirement of the reeviesens of one U.S. oopertment of Transeerieten er einer ecoliseele reew6every seenees. saciuding the cowament of eay cowntry throven or mee waech the sectees weil be teeneserted.

l

3. This certilesete is issued on ene bases of 4 nafety annive e resort of the pechose deo en er speseesien-l 3.iei P,ee.r.d ov rueme end e *e.;:

2.ibi ride one i.eainf.seiien se,eoe,, o, opoli.ien:

Allied Chemical Corporation Allied-General Nuclear Services application i

P.O. Box 430 dated April 29, 1975, as supplemented.-

l Metropolis, IL 62960 2.ici oocnet N..

71-6273

e. CONDITIONS nis certificeie is connetmasi we.n the toitusing of ine resoeremonis of so sert o of 10 cP R 7.. segnanie, ead ene corweimas seeen=d ta i e. s be4.

l

s. oes..oisoa.f Pene,.a. ene 4.in.riese C at.nts. Messe N.,,e.,. ein.ie ci.e. oiner ceae ions. ene Referea.s; (a) Packaging (1) Model Nos.:

48A, 48X, 48F, and 48Y (2) Description

  • Metal 45 inch UFs cylinders as described in Section 7, ORO-651, Rev. 3.

(b) Contents (1) Type and form of material (1) Uranium hexafluoride (UFs) heels.

(ii) Uranium hexafluoride (UF ) in solid form which meets the requirements as low specific activity material as defined in 10 CFR $71.4(g).

! N/&f

//__

cid !gw ~

+/ /

j(f e

e

l Page 2 - Certificate'No. 6273 - Revision No. 4 - Docket No. ~71-6273 5.

(b) Contents (continued)

(2)

Maximum quantities of material per package (i) For the contents described in 5(b)(1)(1):

Type A quantities of fissile radioactive material with a maximum U-235 enrichment, pounds UF, and U-235 content for the cylinder models as follows:

Model Max. Enrichment Max. UFs Max. U-235 Number w/o U-235 Pounds kas 48A, 84X 4.5 50.0 0.690 48F, 48Y (11) For the contents described in 5(b)(1)(ii):

Maximum U-235 enrichment, pounds UF., and U-235 content for the cylinder models as follows:

Max. Enrichment Model w/o Max. UF Max. U-235 6

Number U-235 Pounds kas 48X, 48A 1.0 21,030 64.5 48F 1.0 27,030 82.9 48Y 1.0 27,560 84.5 (c) Fissile Class For the contents described in 5(b)(1)(1) and limited in 5(b)(2)(1).

Fissile Class 6.

Valve protectors shall be provided as described in ORO-651, Rev. 3, 7.

The fabrication, assembly, testing, maintenance, and use of packagings shall be in accordance with the requirements of ORO-65), Rev. 3.

Tolerance dimensions for the Model No. 48-Y cylinder may be in accordance with Attachment I to Virginia Electric and Power Company letter dated December 20, 1976.

8.

For the contents described in 5(b)(1)(ii) and limited in 5(b)(2)(ii) the package shall be transported on a motor vehicle, railroad car, aircraft, inland water craft, or hold or deck of a seagoing vessel assigned for the sole use of the shipper.

s

Page 3 - Certificate'No. 6273 - Revision No. 4 - Docket No. 71-6273 9.

The packages authorized by this certificiate are hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10.

Expiration de.te:

November 30, 1985.

REFERENCES Allied-General Nuclear Services application dated April 29, 1975.

Supplement dated:

July 29, 1975.

Fissile Class I Shipment of Uranium Hexafluoride " Heel", Cylinders, K-L-6249, Rev.1, June 5, 1974.

' - ~ ~

^ ' ~

Uranium Hexafluoride Handling Procedures and Container Criteria, ORO-651, Rev. 3, August 1972.

~'

AdditionalsupplementfortheModelNo.'48-Ypackaging: Virginia Electric and Power Company supplement dated December 20, 1976.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

& Oc. +N0 WCharles E. MacDonald, Chief l

g Transportation certification Branch Division of Fuel Cycle and

_, Material Safety i

NOV 061980

~

Date:

l

  • '"Qm' qz 4, y

O i

O 4

i I

p_

- i.c h _g cy.

N DOCKET NO.

.at,nos co m et so.

/Ob5 Yd

^

DATE 07 DOC.

DATE RCVD.

- /8 )

{

/

FCUF PDR

/

FCAF LPDR

",,' w It.E aEF.

WUR SAFEGUARDS _

FCTC OT11ER DESCRIPTION:

)?)AA/M Aa412At W -h/tud>(6X8htMC,

-,% m,.u ds 7,,l, r

G

//hd

[ INITIAL; O me A.

e -

t

.. i,

.].

Wu j

-..--.w.