{{#Wiki_filter:I ? ~ O COMANCHE PEAK STEAM ELECTRIC STATION EMERGENCY ILISPONSE GUIDELINE GENERIC PIJLNT COMPARISON GENERIC PLANT COMPARISON O REVISION DATE ocenhor 11-1985 (Revision 1) SUBMITTED BY M\\ kda TITLE Sr. Engr. DATE 10/31/85 Ni iiI // ___ _ '- ! < l REVIEWED BY /f' /// h?m.,' TA> 88 DATE // / ' / /'> - , i, / I ' ENGINEER APPROVED BY Ji DATE /u' E < i ,/ OPERATIONS ENGINEER e l O B512260096 851216 ODA-204-5 PDR ADOCK 050 5 F
t O Generic Plant Comparison to CPSES System CPSES differences Justification Completed RCS The RCS has no bypass manifoldi Yes p. k of 18. Reference FASR i and untilizes N-16 detectors.
- p. 7.2-16 Section 7.2.1.1.h, 7 2.1.1 & 7.2.1.1.h.2.
l RCS The over pressure protection Yes p. 5 of 18. Reference FSAR for RCS at low temperaturs is
- p. 7.6-22 Section 7.6.8.
automatically placed in service ECCS CPSES design does not incor-Yes p. 6 of18. Reference Westing-porate a BIT as part of ECCS. house proposal for BORON REDUCTION / BIT REMOVAL ANALYSIS and W-letter i TSX(ATP) 79-325 concerning the same j matter. [ ECCS Charging miniflows do not re-Yes p. 7 of 18. Reference l main open on an SI signal. 2323-M1-0255 & 2323-M1-2255-21. Containment The containment fan coolers Yes p. S of 18. Reference FSAR j Ventilation at CPSES, are not used for Sec. 6.2.2., p. 6.2 h2. heat removal purposes in i emergency conditions. Containment Ventilation Chill Water is the Yes p. 9 of 18. Reference FSAR Ventilation cooling supply to the Contain-Sec. 9.kA.l.1, p. 9.kA-1 & i n.ent Air Cooling and Recire. 2323-M1-0300. Fans. i 1 Main CPSES design does not utilize Yes p.10 of 18.. Reference FSAR i Feedvater a Motor Driven Feed Pump
- p. 10.4-58.
i 4 Main The feedvater system design Yes p.11of 18. Reference Feedwater causes slight variations in 2323-M1-2203-05, 07 & 08 i the valves that are closed on feedwater isolation. J Auxiliary Each Motor Driven AFW pump is Yes p.12 of 18. Reference FSAR Feedvater normally aligned to feed 2 SGs
- p. 10.k-80.
but can be aligned to feed all h SGs. i PAGE 2 0F 18 0 oo^-2o' ! i 4
_- = O Generic Plant Comparison to CPSES j System CPSES differences Justification Complaced Reactor Vesse] CPSES does not plan to have Yes p.13 of18. Reference Tech Specs Level Indica-RVLIS in operation until the Table 3.3-10, p. 3/h.3-62. tion System first refueling outage. Containment CPSES utilizes Four Contain-Yes p. 14 of 18. Reference FSAR Spray ment Spray Pumps for 2 trains. Sect. 6.5 2, p. 6.5-12 and 2323-M1-0232. 4 Containment The Containment Spray pumps Yes p.15 of 18. Reference FSAR Spray get a start signal on a SI
- p. 6-2-16 (23].
signal, as well as Phase "B" and Manual. ECCS RWST level low-lov auto Yes p.16 of 18. Reference FSAR switchover to containment
- p. 6.3-24 (22] and 2323-M1-2263-06 sump arrangement, including auto switch over block.
RCS CPSES utilize 700# nitrogen Yes p.17 of 18. Reference FSAR to operate their PORVs. Sec. 5.k.13.2., p. 5.k-80 and 2323-M1-0262. s N/A (Procedur( Incorporate Adverse Containment Yes p.18 of 18. Reference Simulator Foldout Page) Criteria to foldout page and use of ERGS and Human Factors Concerna. delete Red Path Summary. PAGE 3 Oy 18 i ODA-204-Sa . m
1. Difference Description CPSES does not utilize a bypass line T hot I and T cold measurements for the purpose of RCS average temoeratures, i i. 2. Justification The bypass manifold arrangement has been replaced with a N-16 monitor and an in-line T cold measurement. The N-16 power monitor measures N-16 present in RCS due to neutron activation of oxygen con-tained in water. This is used with T cold to determine T avg. Indication for all temperatures remain the same. 3. Completed by b f-4-8h DATE / / The difference mentioned above does not compromise the generic O technical basis for the guidelines. SM @h / 9 'l b 94 ENGINEER ' DAfE The difference mahtioned above does not affect the overall objective of the Plant Specific ERG's GLAak @bs s' 9 ls+ ENGINEER DATE Generic Procedure
Reference:
E0P-0.0, EOS-0.1, EOS-1.1 l ) Comments: l PAGE 4 0F 18 I ODA-204-5b il --Mtt tm--.- +.. -, - -.9. ,m,. .n, . -.--._ -,, _y._..., _ .-----.-,g,,,. Ag,w- -=.ww_,e.mt.wn mpry%.,%-,ww.ppp,eyy mm,w --,,.--g---
i O l 1. Difference Description The RCS overpressure system at low temperature is automatically place in service. .i 2. Justification RCS lov temperature pressure control includes automatic actuation logic for 2 Pressurizer power operated relief valves. This actuation logic vill only be unbl'ocked when plant oepration is av a temperature below Reference Nil Dutility Temperature. This difference' is an improvement over the reference plant, since no operator action is required 3. Completed by /- Mk DATE 4-6-8h Q The difference mentioned above does not compromise the generic technical basis for the guidelines. OobA bd 9bb %4 D GINEER UATL The difference mentioned above does not affect the overall obje,tive 1 of the Plant Specific ERG's @M @M/TT T4 ENGINEER
- 1) ATE Generic Frocedure
Reference:
NONE (NO OPERATOR ACTION REQUIRED) i l Comments: i PAGE _5 _ 0F 18 O -I ODA-204-5b t i
1. Difference Description The Centrifugal Charging portion of ECCS does not incorporate a Boron Injection Tank 2. Justification CPSES eliminated the BIT and it's associated equipment after Westinghouse completed extensive studies in this area. CPSES design was such that elimination of the BIT did not lower the level of safety. (i.e. flow restrictors integral to SGs). 3. Completed by [ k DATE 1-la -8 Y The difference mentioned above does not compromise the generic technical basis for the guidelines. O RAnh N/ eJsls 4 ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's MMk@b/8R 84- ~ Er3INEER DA'TE Generic Procedure
Reference:
E0P-0.0, EOS-1.1, EOS-1.2, E0P-3.0, ECA-2.1.ECA-3.1,EEA-3.2,ECA-3.3,FRH-0.1,FRP-0.1 Comments: PAGE A 0F A ODA-204-5b O. w. -..r-.n- .-,-..n-- y ~, - ,,---,e
A 4_, -. - -- S.A w -us- - + _a_ ~, __h r -e-n e he -*--.i .e*. d. --a a.----a 9 O 1. Difference Description The charging miniflow valves do not remain open i on an SI at CPSES. I 2. Justification Each CCP has a new miniflow arrangement. On an "S" signal, normal miniflow valves close and valves 8511 A & B open aligning a mini-flow flovpath to a relief to open on high pressure. 8512 A & B are in series with 8511 A & B and are administrative 1y kept open. This differ-ence is an improvement since no operator action is required 3. Completed by bh 'k DATE 7 A h i O-The difference mentioned above does not compromise the generic technical basis for the guidelines. RhkPLa eln /s4 EiGINEER 'DATE The difference mentioned above does not affect the overall objective j of the Plant Specific ERG's Rolnl @b/ RI s /84 4 l ENGINEER 'DATE Generic Procedure
Reference:
E0P-0.0. EOS-0.1, EOS-0.2, EOS-0.h, EOS-1.1. E0P-3.0. EOS-3.1, EOS-3.2, EOS-3.3, ECA-2.1, ECA-3.1, FRH-0.1 Comments: 4 PAGE 7 0F 18 O ODA-204-5b t 4
1 i 1. Difference Description containment Fan coolers are not used at CPSES for heat removal purposes following an accident. 2. Justification The design flowrate of each train of Containment Spray l is sufficient to maintain the Containment pressure and temperature below Containment design values. t 3. Completed by d DATE 1-f, -S I The difference mentioned above does not compromise the generic technical basis for the guidelines. O aowxeso etafu I ENGINEER DATE' The difference mentioned above does not affect the overall objective of the Plant Specific ERG's (Rabd Gho / s/a/e4 INGINEER DATE Generic Procedure
Reference:
E0P-0.0, ECA-0.1, ECA-0.2, ECA-1.1, FRZ-0.1 Comments: PAGE 8 0F _18 ODA-204-5b !O
1. Difference Description The Containment Air Recirculation and cooling System Fans utilize Ventilation Chilled Water as their cooling medium I i while the generic reference plant uses CCW. I 2. Justification This system is not required to operate following a DBA so the post accident CCW cooling is not required. It is required for loss of offsite power so it is sequenced on as well as the Ventilation Chilled Water System, i ~ 3. Completed by bh k DATE Wlp -8 k / / ~ The difference mentioned above does not compromise the generic technical basis for the guidelines. - O e nt o x e u,, ,;,; 4 ENGINEER BATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's @n d. @)aea/ 8/8/84 ENGINEER 'DATE Generic Procedure
Reference:
E0P-0.0, ECA-0.1, ECA-0.2, ECA-1.1, s FRZ-0.1 i Comments: PAGE 9 0F 18 ODA-204-5b O l s -,---,,_v -1
O 1. Difference Description CPSES design does not incorporate a Motor Driven Feedvater Pump 2. Justification CPSES utilizes two 50% capacity feedvater pump. The dual admission feedvater pump turbine drivers operate with steam from two sources. One pump is required up to 50% power and from 50% to full power both are required. The Condensate Pumps can be used to pump water at lover pressures. 3. Completed by bb k DATE '7-6 -N / O The difference mentioned above does not compromise the generic technical basis for the guidelines. Rak @Ls xle /s4 ENCINEER IPATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's @d d @ b 8'sl84 ENGINEER 3 ATE ' Generic Procedure
Reference:
- EOP-0.0, E0P-3.0, EOS-0.1, EOS-0.2, FRZ-0.1, FRH-0.5, FRH-0.1 Comments:
PAGE 10' 0F '18 l O ODA-204-5b
4 1 l. Difference Description Due to the preheater arrangement in CPSES SGs the feedvater isolation signal closes more valves than the same signal of the generic plant reference. i r i 2. Justification A feedvater isolation signal closes the F.W. Preheater Valves and F.W. Splitflow Bypass Valve in addition to the normal valves. This ensures feedvater isolation to the SGs. These additional valves are i checked in the steps for feedvater isolation of the emergency procedures. 3. Completed by I_h k DATE 7 - (p - S k The difference mentioned above does not compromise the generic i technical basis for the guidelines. O %JLaA hw 8)sle 4 ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's GloatsA Gl o / 8 ?elB+ ENGINEER DATE Generic Procedure
Reference:
E0P-0.0, EOS-0.1, E0P-1.0, E0P-2.0, E0P-3.0. ECA-3.1. FRZ-0.1, FRH-0.3, FRH-0.2 t Comments: 1 PAGE 'l l 0F 18 j 1 ODA-204-5b P -ar-e v ---Tr7-- -r --i-------e-+ ---e em,-v-~--'*w-e ae---- v-me-v- ~ - -e--
- ~--***'-m-*--e
O 1. Difference Description The generic plant reference refers to the Motor Driven AFW pumps being lined up to 2 SGs. CPSES's Motor Driven AFW pumps are normally lined up to 2 SGs but have the capability to be lined up to h SGs. 2. Justification A norr. ally closed interconnection between the motor driven pump discharge lines permits either pump to feed all four SGs. This provides a method for maintaining SG vater level on a long-term basis, but will not normally be used. This difference is an improvement over-the generic. 3. Completed by b /- DATE @b -8 'O The difference mentioned above does not compromise the generic technical basis for the guidelines. Redtml6hn R1a184 ENGINEER ITATE' The difference mentioned above does not affect the overall objective of the Plant Specific ERG's @A:Jh Aw s/n Ja4 E,iGINEER 17 ATE' Generic Procedure
Reference:
E0P-0.0. E0P-3.0. EOS-0.1. EOS-0.2. FRZ-0.1. FPR-0.5. FRH-0.1 Comments: PAGE 12 0F 18 ODA-204-5b
I O 1. Difference Description The Reactor Vessel Level Indication System at CPSES will not be operational until the first refueling outage f I 4 2. Justification The steps that dealt with RVLIS in the emergency procedure were revised as specified in the background documentation of the ERG's .i to meet plant design at this time. When RVLIS is functional it will be incorvorated. 74-8k '3. Completed by DATE / f-The difference mentioned above does not compromise the generic 1 technical basis for the guidelines. i &kak A/ eb h4 ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's kM@b/ Shf M ENGINEER DATE Generic Procedure
Reference:
FRI-0.3 FRC-0.2. FRC-0.1, ECA-2.1, l ECA-3.1. ECA-3.2. ECA-3.3. EOS-0.h. EOS-1.h. EOS-3.3. EOS-0. 3 Comments: This sheet vill be removed after first refueling when RVLIS is installed. PAGE 13 0F 18 ODA-204-5b 1
O 1. Difference Description Containment Spray pumps get a start signal on j a SI as well as Phase "B" and Manual signals i 2. Justification The CSS discharge valves open on a "P" signal which comes from a Phase "B" or Manual actuations. Having the pump start en an SI anticipates the need of the pump if conditions become more severe. This difference is an improvement over the reference plant. ~ b d DATE '/-0-8 3. Completed by 'l i f The difference mentioned above does not compromise the generic technical basis for the guidelines. koNkb 8 'l l 24 ENGINEER DATE' The difference mentioned above does no: affect the overall objective of the Plant Specific ERC's @ h /8' LIB 4 ENGINEER DATE Generic Procedure
Reference:
E0P-0.0. EOS-0.1. EOS-0.2, E0P-1.0, EOS-1.1, EOS-1.2, EOS-1.3, E0P-3.0, ECA-2.1, ECA-3.1 Comments: 6 PAGE I4 0F -18 ODA-204-5b . - -.. _ _ ~. _. _,. _ _.. _ _ _ _ _. _.. _
O 1. Difference Description The generic reference plant uses a two Contain-ment Spray Pump arrangement, while CPSES has four contaiment spray numus. 2. Justification The redundancy requirements of the CSS are satisfied by dumplicating 2-100% capacity trains, with each train having 2-50% capacity pumps. This difference does not allow one pump failure to remove the capacity of one train completely. 3. Completed by h DATE '7-6 '8 O The difference mentioned above does not compromise the generic technical basis for the guidelines. M bb 8 8 B4 ENGINEER DATI The difference mentioned above does not affect the overall objective of the Plant Specific ERG's 6 Web / sla is4 ' ENGINEER 'DATE Generic Procedure
Reference:
E0P-0.0.' E0P-1.0. EOS-1.3. ECA-2.1 vcA-1.1. FR2-0.1. ECA-0.2 Comments: PAGE 15 0F 18 O ODA-204-Sb
O 1. Difference Description CPSES's design includes an auto switchover of the RWST to the containment sump as RHR pump suction. 2. Justification On an RWST low-lov level signal, coincident with an "S" signal, the containment sump valves to RHR pump will open. This arrangement is also set up with reset switches.(independent of SI reset), that can reset this function after SI is reset. This difference is an. improvement over the reference plant. 3. Completed by bh, DATE 1 b-O I f The difference mentioned above does not compromise the generic O technic 1 basis fer the seide11nes. Rc39A Gb sIBIM ENGINEER DATE The difference mentioned above does not affect the overall objective of the P1 ant Specific ERG's bdiA @Ihrlal R A 84 3GINEER DATE Ceneric Procedure
Reference:
E0P-0.0, E0P-1.0, EOS-1.1, EOS-1.2, EOS-1.3, E0P-3.0, ECA-2.1, ECA-3.1, ECA-3.2 Comments: PAGE 16 0F 18 ODA-204-Sb
O 1. Difference Description The Pressurizer PORV's at CPSES utilizes Nitrogen gas as their pneumatic driver. 2. Justification The PRZR PORV's are pneumatic actuated vavles which respond to a signal from a pressure sensing system or to manual control as per the M-drawing, CPSES uses nitrogen as the pneumatic driver for the PORVs. This is considered a minor difference which does not affect the plant.. bh 54 DATE 7-d-8 3. Completed by / f O-The difference mentioned above does not compromise the generic technical basis for the guidelines. RAAA/ s/s /M ' ENGINEER D' ATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's M @ L / 8/8/84 ENGINEER ~DATE Generic Procedure
Reference:
E0P-0.0. EOS-0.1. EOS-0.2. EOS-0.Lm I E0P-1.0, EOS-1,1, EOS-1.2, E0P-3.0, EOS-3.1, EOS-3.2, EOS-3.3, ECA-2.1, ECA-3.1 Comments: PAGE 17 0F 18 j ODA-204-5b
i-1. Difference Description The CPSES plant specific procedure foldout O page items was revised to incorporate the criteria for determinine whether Adverse Containment Parameters should be used. The FRC red path summary was removed in order to accomodate the above mentinned i change. 2. Justification The generic procedures as written. never mention when Adverse Containment parameters should be used. By placing them on the i foldout page, the operator will have a quick reference to be able to make that determination. The red path summary was removed since the ooerator as well as the STA vill continually be monitorine the critical safety function status trees on the computer or manually if not available. 3. Completed by Ralph Flores DATE 10/31/85 The difference mentioned above does not compromise the generic I technical basis for the guidelines. kokh\\h4/ \\0\\"%\\S( ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's ka Y \\0\\31 9' ENGINEER DATE Generic Procedure
Reference:
EOP-0.0. EOS-0.0. EOS-0.1. EOS-0.2. EOS-0.4, E0P-1.0. EOS-1.1. EOS-1.2. EOS-1.3. EOS-1.4. E0P-3.0, EOS-3.1 EOS-3.2, EOS-3.3, ECA-2.1. ECA-3.1, ECA-3.2, ECA-3.3. Comments: j. PAGE 18 0F 18 ODA-204-5b O . _ _ _. _.. - _,.,,, ~. _ _.,
i s i e 4 b t COMANCHE PEAK STEAM ELECTRIC STATION EMERGENCY RESPONSE GUIDELINE GENERIC PLANT COMPARISON 1 s ~
- i. I l
~ f! 1 _ 5 GENERIC PLANT COMPARISON 4 s ?- { l h REVISION DATE A_urust 15, 198h i I i s i SUBMITTED BY hn_I.Oht k A 1.' \\ - TITLE [/1,,ie-r-/' DATE 3!/O Mf REVIEWED.BY b 10 n k CNU _ DATE b /2 C / hb h ENGINEER APPROVED BY / DATE W / A / / P 9/ / / (/ WPERATIONS ENGINEER ODA-204-5 / - L
i.. ) Generic Plant Comparison to CPSES System CPSES differences Justification Completed RCS The BCS has no bypass manifold: Yes p. h of lT. Reference FASR and untilizes N-16 detectors.
- p. 7.2-16 Section T.2.1.1.4, 7 2.1.1 & T.2.1.1.h.2.
RCS The over pressure protection Yes p. 5 or lT. Reference FSAR for RCS at low temperaturs is
- p. T.6-22 Section T.6.8.
automatically placed in service ECCS CPSES design does not incor-Yes p. 6 of lT. Reference Westing-porate a BIT as part of ECCS. house proposal for BORON REDUCTION / BIT REMOVAL ANALYSIS and W-letter TEX (ATP) 79-325 concerning the same matter. ECCS Charging miniflows do not re-Yes p. 7 or lT. Reference main open on an SI signal. 2323-M1-0255 & 2323-M1-2255-21. Containment The containment fan coolers Yes p. 8 of lT. Reference FSAR Ventilation at CPSES, are not used for Sec. 6.2.2., p. 6.2 h2. heat removal purposes in (s) emergency conditions. ~. Containment Ventilation Chill Water is the Yes p. 9 of lT. Reference FSAR Ventilation cooling supply to the Contain-Sec. 9.4A.l.1, p. 9.hA-1 & ment Air Cooling and Recire. 2323-M1-0300. Fans. Main CPSES design does not utilize Yes p.10 of lT. Reference FSAR Feedwater a Motor Driven Feed Pump
- p. 10.4-58.
Main The feedwater system design Yes p.11 of lT. Reference Feedvater causes slight variations in 2323-M1-2203-05, 07 & 08 the valves that are closed on feedvater isolation. Auxiliary Each Motor Driven AFW pump is Yes p.12 of lT. Reference FSAR Feedwater normally aligned to feed 2 SGs
- p. 10.h-80.
but can be aligned to feed all h SGs. i PAGE 2 0F 17 ODA-204-5a O ., + .,.n..., ,,.,.,-----,.m
i t \\ Generic Plant Comparison to CPSES System CPSES differences Justification Completed Reactor Vesse' CPSES does not plan to have Yes p.13 of 17. Reference Tech Specs Level Indica-RVLIS in operation until the Table 3.3-10, p. 3/h.3-62. tion System first refueling outage. Containment CPSES utilizes Four Contain-Yes p. Ih of 17. Reference FSAR Spray nent Spray Pumps for 2 trains. Sect. 6.5.2, p. 6.5-12 and 2323-M1-0232. Containment The Containment Spray pumps Yes p.15 of 17. Reference FSAR Spray get a start signal on a SI
- p. 6-2-16 [23].
signal, as well as Phase "B" and Manual. ECCS RWST level low-low auto Yes p.16 of 17. Reference FSAR switchover to containment
- p. 6.3-2h [22] and 2323-M1-2263-06 sump arrangement, including auto switch over block.
RCS CPSES utilize 700# nitrogen Yes p.17 of lT. Reference FSAR to operate their PORVs. Sec. 5.h.13.2., p. 5.h-80 and () 2323-M1-0262. PAGE 3 0F 17 ODA-204-5a O
4 v' 1. Difference Description CPSES does not utilize a bynass line T hot and T cold measurements for the nurpose of RCS average temneratures. 2. Justification The bypass manifold arrangement has been replaced with a N-16 monitor and an in-line T cold measurement. The N-16 power monitor i measures N-16 present in RCS due to neutron activation of oxygen con-tained in water. This is used with T cold to determine T avg. Indication for all temperatures remain the same. 3. Completed by [ [b 9-6 -8k DATE / The difference mentioned above does not compromise the generic technical basis for the guidelines. ENGINEER 'DAfE 1 The difference meittioned above does not affect the overall objective of the Plant Specific ERG's koM 9 9 It ENGINEER DATE Generic Procedure
Reference:
E0P-0.0, EOS-0.1, EOS-1.1 i Comments: i PAGE k 0F 17 ODA-204-Sb O I -r-w,-,---.,w--- -mm----r,---o .,p.-...r-, -r..,,,---w..- r-e .w. ..~....----,,%,m--. ---,ene -.-.,m , w.-,w,, ,r.- e - + ~m.,-eee r-
\\.) ' 1. Difference Description The RCS overpressure system at low-temperature is automatienlly place in service. 2. Justification RCS lov temperature pressure control includes automatic actuation logic for 2 Pressurizer power operated relief valves. This actuation logie vill only be unblocked when plant oepration is at a temperature below Reference Nil Dutility Temperature. This difference is an improvement over the reference plant, since no operator action is required 3. Completed by /I/- J k DATE 7 8Y / The difference mentioned above does not compromise the generic technical basis for the guidelines. EFGINEER LIATL The difference mentioned above does not affect the overall objective-of the Plant Specific ERG's GJud ikA/ tbT T4 ENGINEER DATE Generic Procedure
Reference:
NONE (No CPERATOR ACTION REQUIRED) Comments: PAGE 5 0F 17 ODA-204-5b O
m.,J a -a-A .2.e-,e* a ---- - e-- + 2--+A----4--a----e -A-- w a# u 44 1. Difference Description The Centrifugal Charging portion of ECCS does not incorporate a Boron Injection Tank I 4 2. Justification CPSES eliminated the BIT and it's associated equipment after Westinghouse completed extensive studies in this area. CPSES design was such that elimination of the BIT did not lower the level of safety. (i.e. flow restrictors integral to SGs). 3. Completed by [ / I[ DATE 1-6 -8 Y / The difference mentioned above does not compromise the generic technical basis for the guidelines. Nd @h/ Bf 8/84 ENGINEER ~ DATE I The difference mentioned above does not affect the overall objective of the Plant Specific ERG's b M @b/8R)84 d ENGINEER DATE Generic Procedure
Reference:
E0P-0.0, EOS-1.1, EOS-1.2, E0P-3.0, ECA-2.1, ECA-3.1, ECA-3.2, ECA-3.3, FEH-0.1, FRP-0.1 l Comments: PAGE 6 0F 17 i ODA-204-5b O 4 ~- - -,, -,., _ -,,,, --.a -- e --,-n- ,-n,,-r-- -m,n- -e---nw. ,,vnn.,--,------m---w-r -y, e v----nr -erw.-
1. Difference Description The charging miniflow valves do not remain open on an SI at CPSES. 2. Justification Each CCP has a new miniflow arrangement. On an "S" signal, normal miniflow valves close and valves 8511 A & B open aligning a mini-flow flovpath to a relief to open on high pressure. 8512 A & B are in series with 8511 A & B and are administratively kept open. This differ-ence is an improvement since no operator action is required / 3. Completed by dhAk DATE 7-{ -Sk / The difference mentioned above does not compromise the generic technical basis for che guidelines. f 3 Rink Rw els /s4 v ENGINEER 'DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's 0W1 A/ n/ s /s4 CNGINEER 'DATE Generic Procedure
Reference:
E0P-0.0, EOS-0.1, E03-0.2, EOS-0.h, FOS-1.1. EnP-3.0. EOS-1.1, EOS-1.2, E00-3.3, ECA-2.1, ECA-3.1, FRH-0.1 Comments: PAGE 7 0F 17 ODA-204-Sb p .E
1. Difference Description Containment Fan coolers are not used at CPSES O fcr heat removal purposes following an accident. 2. Justification The design flovrate of each train of Containment Sprav is sufficient to maintain the Containment pressure and temperature below Containment design values. 3. Completed by /Ah id DATE 7 - f, - 8 l[ l The difference mentioned above does not compromise the generic technical basis for the guidelines. 77 bldCLh T hi.e / Q[R/44 V ENGINEER DATE' The difference mentioned above does not affect the overall objective of the Plant Specific ERG's Illnhilh T Inte / 9[R h) / INGINEER DATE Generic Procedure
Reference:
E0P-0.0, ECA-0.1, ECA-0.2, ECA-1.1, FRZ-0.1 Comments: PAGE 8 0F 17 ODA-204-5b O) v
1. Difference Description The Containment Air Recirculation and cooling System Fans utilize Ventilation Chilled Water as their cooling medium while the generic reference plant uses CCW. 2. Justification This system is not required to operate following a DBA so the post accident CCW cooling is not required. It is required for loss of offsite power so it is sequenced on as well as the Ventilation Chilled Water System, 3. Completed by deh I DATE '7-6-SN / ~ The difference mentioned above does not compromise the generic technical basis for the guidelines, h Sako% @%i nIn 18+ C/ ENGINEER OATI! The difference mentioned above does not affect the overall objective of the Plant Specific ERG's & bh b / als/84 ENGINEER 'DATE s. Generic Procedure
Reference:
E0P-0.0, ECA-0.1, ECA-0.2, ECA-1.1, FRZ-0.1 Comments: PAGE 9 0F 17 ODA-204-5b ,r \\.) s
-~ I 1. Difference Description CPSES design does not incorporate a Motor a i i Driven Feedwater Pump i i i !i i 2. Justification CPSES utilizes two 50% capacity feedwater pump. The dual admission feedvater pump turbine drivers operate with steam from 4 two sources. One pump is required up to 50% power and from 50% to full power both are required. The Condensate Pumps can be used to pump water at lower pressures. Ib b DATE '/-6-F(f 3. Completed by / / / The diffarence mentioned above does not compromise the generic technical basis for the guidelines. i bd NJ RfB /84 ENCINEER IhTE~ l The difference mentioned above does not affect the overall objective J of the Plant Specific ERG's i @dd C 8Je/84-DIGINEER DATE ' Generic Procedure
Reference:
"EOP-0.0, E0P-3.0, EOS-0.1, EOS-0.2, FRZ-0.1, FRH-0.5, FRH-0.1 ( l 4 I } Comments: j PAGE 10 op 17 i i ODA-204-5b ' O 4 <~r+ss-ww e-v-ee-www-~-wwy>wn----er----- ~~n, ,n -w-,-n,avv,-e _y-m,. m---<w=ce---,. , ems,v+~wm---,r-,--4-'rmr~*v-=-w
1. Difference Description Due to the preheater arrangement in CPSES SGs the feedvater isolation signal closes more valves than the sene signal of the generic plant reference. 2. Justification A feedvater isolation signal closes the F.W. Preheater Valves and F.W. Splitflow Bypass Valve in addition to the normal valves. This ensures feedvater isolation to the SGs. These additional valves are checked in the steps for feedvater isolation of the emergency procedures. 3. Completed by I.h Jk DATE 7 SY The difference mentioned above does not compromise the generic technical basis for the guidelines. S& @S 8]Sl6 4 (~hj ENGINEER 'DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's $dh bb/ 8 6 f 64 KNGINEER DATE Generic Procedure
Reference:
E0P-0.0, EOS-0.1, E0P-1.0, EOP-2.0, E0P-3.0. ECA-3.1. FRZ-0.1, FRH-0.3, FEH-0.2 Comments: PAGE 11 0F 17 ODA-204-Sb O Lj
1. Difference Description The generic plant reference refers to the Motor Driven AFW pumps being lined up to 2 SGs. CPSES's Motor Driven AFW pumps are normally lined up to 2 SGs but have the capability to be lined up to h SGs. 2. Justification A normally closed interconnection between the motor driven pump discharge lines permits either pump to feed all four SGs. This provides a method for maintaining SG water level on a long-term basis, but will not normally be used. This difference is an improvement over the generic. k //~IwN DATE 7-lo -O 3. Completed by t The difference mentioned above does not compromise the generic technical basis for the guidelines. ENGINEER UATE' The difference mentioned above does not affect the overall objective of the Plant Specific ERG's
- @enk N s/nlas ESGINEER UATE' Generic Procedure
Reference:
E0P-0.0. E0P-).0. FOS-0.1. ens-0.2 FP7-0.1. FFH-0.5. FRH-0.1 Comments: PAGE 12 or 17 ODA-204-5b O
_ _ _. ~. - _ l 1. Difference Description The Reactor Vessel Level Indication System at i CPSES will not be operational until the first refueling outage 2. Justification The steps that dealt with RVLIS in the emergency procedure were revised as specified in the background documentation of the ERG's to meet plant desitrn at this time. When RVLIS is functional it will ha incornorated. 3. Completed by i h k DATE 7-8 k / /- The difference mentioned above does not compromise the generic technical basis for the guidelines. Oekak @L/ 917 114 ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's k M @ b / Sb/ti ENGINEER DATE Generic Procedure
Reference:
FRT-0.1. FRC-0.2. FRC-0.1, ECA-2.1, ECA-3,1. ECA-3.2. ECA-3. 3. EOS-0.h, EOS-1.h, EOS-1. 3. EOS-0.1 1 Comments: This sheet will be removed after first refueling when RVLIS l is installed. PAGE 13 or 17 i l ODA-204-5b O i
1. Difference Description Containment Spray pumps cet a start sienal on a SI as well as Phase "B" and Manual signals 2. Justification The CSS discharge valves open on a "P" signal which comes from a Phace "B" or Manual actuations. Having the pump start on an SI anticipates the need of the pump if conditions become more severe. This difference is an improvement over the reference plant. 3. Completed by d b II DATE 7-0 -8 Y / p The difference mentioned above does not compromise the generic technical basis for the guidelines. ENDINEER DhTE' The difference mentioned above does not affect the overall objective of the Plant Specific ERG's @ h/8'lI%$ ENGINEER DATE Generic Procedure Reference Ent-0.0. EcS-0.1. Ens-0.2. E0P-1.0, EOS-1.1, EOS-1.2, EOS-1.3, E0P-3.0, ECA-2.1., ECA-3.1 Comments: PAGE lb 0F 17 ODA-204-5b O
-. -. = _. _ - _ _ - -. - _ _ - ) 1. Difference Description The generic reference plant uses a two contnin-ment Spray Pump arrangement, while CPSES has four contniment snrny nurmn. I i l 2. Justification The redundancy requirements of the CSS are satisfied by dumplicating 2-100T capacity trains, with each train having 2-50% capacity i pumpo. This difference does not allow one pump failure to remove the i j capacity of one train completely. 1 i i 3. Completed by /-. ok DATE '7-6'8 The difference mentioned above does not compromise the generic technical basis for the guidelines. i M kb 8 8. B4 ENGINEER flat ! The difference mentioned above does not affect the overall objective of the Plant Specific ERC's l @ N T k lSIBI84 i j INGINEEa 'DATE i i l Generic Procedure Reference Fnt-o.n. Ent-1.n. FM-1. 3 ECA-2.1 j l r A-,.i. vne n.i. ecA-o.c J I i Comments: I l PAGE 15 0F 17 1 ODA-204-5b e i l
r 1. Difference Description CPSES's design includes an auto switchover of the RWST to the containment sump as RHR pump suction. 2. Justification On an RWST low-lov level signal, coincident with an "S" signal, the containment sump valves to RHR pump will open. This arrangement is also set up with reset switches (independent of SI reset), that can reset this function after SI is recet. This difference is an improvement over the reference plant. 3. Completed by k.h w'((-- DATE 7 d' ~ O y / The difference mentioned above does not compromise the generic technical basis for the guidelines. && Theel bis]B4 ENGINEER DATE The difference mentioned above does not affect the overall objective of the Plant Specific ERG's $dhA band R A R4 ENGINEER DATE Generic Procedure Reference E0P-0.0, E0P-1.0, E0G-1.1 E00-1.2, E00-1.3, E0P-3.0, ECA-2.1. ECA-3 1, ECA-3 2 l Comments: PAGE 16 0F 17 ODA-204-5b l O I
l l 1. Difference Description The Pressurizer PORV's at CPSES utilizes Hitrogen gas as their pneumatic driver. l I 2. Justification The PRZR PORV's are pneumatic actuated vavles which respond to a signal from a pressure sensing system or to manual control as per l the M-drawing, CPSES uses nitrogen as the pneumatic driver for the PORVs. l This is considered a minor difference which does not affect the plant. I i i 3. Completed by d6-h, d. DATE 7-0-8 The difference mentioned above does not compromise the generic technical basis for the guidelines. 'EiGINEER D' ATE l The difference mentioned above does not affect the overall objective of the Plant Specific ERC's WTGI 8l8l84 ENGINEER 'DATE Generic Procedure
Reference:
EnP-0.0. Ens-0.1. Ens-0.2. Ens-0.L. I E0P-1.0. EOS-1.1. EOS-1.2. E0P-1.0. EOS-1.1. EOS-1.2. EOS-1.3, FCA-2.1, i ECA-1.1 I Comments: PAGE 17 0F 17 l i ODA-204-5b l O l _ _ - - _ _ - _ - - - _ - _ - - _ - _ - _ _ _ _ - - - _ - _ - _ _ _ _ _ - - - _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - _ - _ _ - _ _.,, - _ - _ _ _ _ _ _ - _ _ _ _ _ _. _ _. _ _ _ _ _ _ _ - - _ - - _ - _. _ _}}