REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE AMENDED IN ITS ENTIRETY E: NR-0487-D-101-S DATE: February 14, 1997 PAGE 1 OF 7 4
DEVICE TYPE: Beta Gauging Device MODEL:
,Nsh-l' 4
^
4 y
(.-
DISTRIBUTOR <
f Dyno Overlays, Inc.* --
i
- 121 Vermont Avdnue, S.
Hayward, W'I.548'3' 4
(formerly;Noresin Inc.)
MANUFACTURER:
Oy Scienta Ab j
Valimotie-1 A SF-00380; Helsinki, Finland l
v-SEAT.Rn SOURCE MODEL DESIGNATION:
Amersham KAC.D1 ISOTOPE:
MAXIMUM ACTIVITY:
I Krypton-85 200 Millicuries (7.4 GBq)
LEAK TEST FREOUENCY:
Not Required PRINCIPAL USE:
(E) Beta Gauge CUSTOM DEVICE:
X YES NO CUSTOM USER:
Dyno Overlays, Inc.
121 Vermont Avenue, S.
Hayward, WI 54843 9702270110 970219 PDR RC SSD PDR
REGISTRY-OF RADIOACTIVE" SEALED SOURCES AND DEVICES SAFETY = EVALUATION OF DEVICE AMENDED IN ITS: ENTIRETY s
NQ.: NR-0487-D-101-S-DATE: February.14, 1997 PAGE 2 OF 7 f
DEVICE TYPEr Be a'Gaugin~g Device ts
~
v 4
J, DESCRIPTION:
j t.
s
~
The devicefconsibts.ofitwo parts: thel transmitter, and the
^
receiver.
4 The transmitter consists of.aescre$ned source holder enclosed.in a aluminum box having dimensions of 8.66 X 4.33 X 3.15 inches (220 X 110 X 80 millimeters)., The source holder consists of an l
Amersham source capsule and collimator 1.57" (40 mm) in diameter enclosed in an aluminum tube.
This source model is smaller than
{
the original source model the device was designed for, therefore, a teflon' sleeve was inserted over the new source so that it was the same size as the original source model.
The source is held in place by a lock ring. The aluminum tube is attached to a sliding plate with screws.
The other end of the sliding plate is attached to a pneumatic cylinder that allows the source assembly to move by the use of guide rails and ball bearings in contact with the sliding plate.
The end plates of the device are sealed with gaskets to reduce intrusion of moisture and dust within the device.
As the cylinder engages the source is moved to the center of the holder body where the radiation can pass through a thin teflon diaphragm.
When the source capsule is in this center position a red plastic pin extrudes through a side cover plate giving a visible warning that the source is in the "open" position.
An inductive transducer is also installed which sends an electric signal to indicate the position of the source capsule.
Also, two safety lights one at each end are fitted to indicate the position of the source.
If the source is in the open position a red light with the radioactive symbol lights, if the source is in the closed position then the green light with the radioactive symbol crossed out lights.
u M
i:
t u
?',
i g
m.,
s l
' REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES l
i SA,FETY. EVALUATION OF DEVICE l
}
ED IN~ITS ENTIRETY s
r a
IEL: NR-0487-Dv101-S t
DATER February 14, 1997 PAGE 3 OF 7
- s T
1
','a
.e' y
>E 4-
~..
r DEVICE TYPEi BetaeGauging Device' i
3; 3
4,..
5 l
.,l,.
- r 3
pESCRIPTION i,(Co'nb ' d) l l
Emergency stops are. installed at'.,each end to shut the source and l
to stop the scanner.
If for some reason the air supply to the pneumatic cylinde'r failed,' a spring would automatically cause the source to return to the*sa'fe. position.
l The calibration period for this device is every 6 months and maintenance on the device may occur daily.
The source is loaded into the source holder by removing a plate located on the top of the device.
Once the source is loaded by authorized personnel it is sealed with bolts and lock washers and then covered with a sticker.
l The receiver is a special alloy Ion Chamber.
l A 1.97" x 1.97" x 0.197" (500 mm x 500 mm x 5 mm) aluminum screen i
plate is attached to each the receiver and to the transmitter.
The transmitter and receiver are fitted to a 0-Frame Scanner with a maximum distance between the screening plates.
l During tran' sport of the device a transport lock is installed on the side of the transmitter with screws to lock the sources in a safe position, l
LABELING:
A 3.94" x 1.97" (100 mm x 50 mm) label containing the radiation symbol, date, isotiope, and. activity is screwed into the side of the-transmitter.
The O-Frame Scanner contains a large label with a radiation symbol and text stating " CAUTION - RADIOACTIVE MATERIAL".[The device"also hasfa label showing the manufacturer, and model numbsr.
l t
4
/
5 e
I t
6 i
g
. E
) '/
g t
~
~..
~
~ _
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE AMENDED IN ITS ENTIRETY i
N.Q : NR-0487-D-101-S DATE-February 14, 1997 PAGE 4 OF 7 DEVICE TYPEe Beta Gauging Device 1
'l DIAGRAMe See attachments 1-4.
1 CONDITIONS OF USE:
The device will be used in areas having environments that are fit for human occupancy.'"Although the devices are located near a drying oven'the temperature of the surrounding areas is kept low by the use of exhaust ventilation.
PROTOTYPE"TESTINGi 7
s s
Dyno Overlays Inc.'di'd not' provide specific information on the testingof.thelpr6totype,devi'ces.
Rather they demonstrated the devices ability to withstand its operating environment by use of the(ANSI designat'on 6f' the AmeEsham source augmented with the i
~
operatiionalf experience of. the ; gauge manuf actured by Oy Scienta in Europe over a1301 year' period.I
.;y G
.i
..j r'
i, t.'
4 EXTERNAL RADIATION LEVELS?
- 2.,.
s~
4 Oy Scienta reported the following maximum radiation levels for the device with shutter open.
l Distance from tNe souYce.
Measured radiation levels surface
.100.0 mR/hr (1000.0 pSv/hr) l 9.84" (25.0 cm) 2.5 mR/hr (25.0 pSv/hr)
[
39.4" (100.0 cm)-
0.1 mR/hr (10.0 pSv/hr)
I l
J 4 j),
e
+
6.
l REGISTRY'OF RADIOACTIVEsSEALED SOURCES AND DEVICES
" SAFETY EVALUATION OF DEVICE AMENDEDIIN'ITS' ENTIRETY w ;;t:
e'
+
4 HQ : NR-0487-D~101-S DATE:, February 14, 1997 PAGE 5 OF 7 e
9 s'
.,c 9
b
+8 Beta Gauging; Device DEVICE TYPE:
- r OUALITY CONTROL AND ASSURANCE-a Dyno Overlays engineers will check the device design for
.conformance to their dimensional specifications and dose rate specifications as defined in the contractual agreement.
Prior to formal operation Dyno Overlays will determine adequacy of the device to measure product thickness.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
- The model Nsh-1 gauging device shall be distributed only to the specific licensee referred to in this document (Dyno Overlays, Inc.).
- This device is to be used on *. Scienta 0-Frame Scanner and the distance between the measuring plates shall be no greater than 0.630" (16 mm).
The device shall be installed and tested for proper l
operation of the source exposure mechanism, safety warning components, proper labelling, external radiation levels by Oy Scienta Ab under the Dyno Overlays, Inc. specific license or by other persons specifically licensed by the NRC or an Agreement State.
License Reviewer Note: Dyno Overlays, Inc. should be required l
to perform a shutter function test commensurate to performing
[
physical inventory of the devices.
i This registration sheet and tihe information contained with l
j the references shall notebe changed without the written consent of the NRC.
l r
1
(
Y
=
'e r
.h
'$r
~
s.
p.
~
t 9,
- 3 1
4 REGISTRY OF IOACT E SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE
. AMENDED IN ITS, ENTIRETY f
NQ.: NR-0487-D-101~-S-
,eDATE Feb'ruary 14, 1997 PAGE 6 OF 7 DEVICE TYPE: Beta Gauging Device I
SAFETY ANALYSIS
SUMMARY
Based on our review of the information cited below, we continue to. conclude that the model Nsh-1 gauging device design is
]
acceptable for custom licensing purposes.
Furthermore, we
]
conclude that the device as designed would be expected to maintain its integrity for normal conditions of use with might occur during uses specified in this certification.
Not enough data was available to determine the ability of the device to withstand accidental conditions of use.
However, if the device was involved in an incident it is highly likely that the source would also be damaged the Krypton gas would disperse very rapidly in the environment causing minimal exposure the the
. workers.
REFERENCES:
The following supporting documents for device model Nsh-1 are hereby incorporated by references and are made a part of this registry document.
Telefaxes from Scienta Sytem dated August 17,1988, August 5, 1988 andjenclosures thereto.
Telefax'from Noresin Inc. dated July 14, 1988.
4 Noresin-Inc.'apllications dated February 26, 1988, and February 17, 1988.
+
NRC License Number 48-25892-01 1
4 WN
^
9
~,;s-7-
i./
s v.
,a
- .f r, ' ~,
s
>><e 1
i
- [, ' %
- a l*,
.. ' ' ' r '..
a' REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETI> EVALUATION OF DEVICE AMENDED IN ITS ENTIRETY HCL: NR-0487-D-101-S *
.DATEt February 14, 1997 PAGE 7 OF 7 DJ2VICE TYPE Beta Gauging Device ISSUING AGENCYt
/
U.S. Nuclear Regulatory Commission
/
Date: February 14. 1997 Reviewer:
/-
'[f
~
JQfin W/Lubinski
'jl e
N b ' '/'M Date: February 14. 1997 Concurrence:
-/
5 t'd v e n L. Baggett.
l l
l i
i i
n a
y e-r e
f es
- . #r. j
' #g h
g a
l 1
C 3
4 D I
,g
....e i
,v.-
y
.g s.
l
[
N._
I 1
.-_-._ -.~..
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
HQ_:. NR-0487-D-101-S DATE: February 14, 1997 ATTACHMENT 1 DEVICE TYPE:
Beta Gauging Device O Frame Scanner TOPSC A high questy 0-Frame Scanner is essential for
$clents has manufactured 0-Frame Scanners for ensuring accurate measurement with transducers more than 20 m.1-_Mimproving the quellty measuring sheetflke matertels. As long as the accuracy and y of mechanical and electrical depends on the movement and intemai diff erences in constructions.
elscanners are available forwety the positions of rnesauring heads in operation, the widthe up to 12 meters.
precielon and quality of the constrbction is vital for
)
meeting the highest possible demands.
i
-,.9 d
(
i
~ " '..
FG.N. -
6 hEG.5.
- e. v...h ':.
/
~
~
.n
- ;4-1 r :. * - - -.
g
%p n;
g r--
^* _ y..._ f _ ~ w g ~
^
m
,we*..
"Ah g) g
.4
.g
.; yM; v Y. '
- ,' r *.n - ~
Gty.9 <
, ' l'l h" f*
~.'~ & _.~.
n Fremoworic The scanner is built around a sturdy Electronic Drive and Control: The motor used in the wolded framework construction. Two end pieces CH rame Scanneric a normat three9hase made of 350 mm LReam sections are connected with motor. However, it only needs a mairu four Rectangular Hollow Section (RHS) pipes.
connection, as it is operated over a frequency Precision steel rods of very high dimensional accuracy converter which controls the speed and other functions and barge outside diameter are fitted between thn end like smooth start-up and braking of the motor, pioces using specla! bearings. The carr;ag6s which The electronic control system ircorporates few hold the transducers move synchronously along the moving parts and is protected agalnst eatemal7nter-rods on both sides of the web running on closed imear bau bea% whh a mWmurn clearance forence. The carriage movement can be controlled manually (over a Control Panell or automatically from The carriages are moved by two toothed belts the computer (Operator Station) through the connected to vertical shafts. One of the sha*ts is driven communication network. As limit switches are of via a flexible clute by a motor-poworod gear unit.
norH:ontact type. The electronic circuitry is encased The worm-type gear nwgr.w.tes a friction clutch in an End Box that meets IP-64 sealing specifications arrangement wt*A idles at a specific resisting force on the carrleges, giving additional safety for emergencies.
All parts of the framework are plated or epoxy-painted for
&iv.;wn resistance. The bearings are self-I ting and the whole construction is well encapsulated to ensure a minimum of maintenance.
Service intervals depend on the factory environment, but a monthly insnactinn ne movina a.,...ha..w
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-0487-D-101-S DATE: February 14, 1997 ATTACHMENT 2 DEVICE TYPEr Beta Gauging Device TOP ' VIEW l
1 I
< 25 USv/h s
l 7
r
( 25 USv/h gguSv/h i
.J L
25 cm
\\
I 100 Safety Plates 5 mm Al I
v
< 25 uSveh
[
I
< 1 uSv/h SIDE UIEW
)
s Sur(ace Radiation Level 00 uM Source Holder l 6 l
< 16 mm y
i r
n Ion Chamber Source Holder i NSH-1 lon Chamber ZA/D Radiation levels are measured uith l
the shutter in open position.
.i i
i 10 microSievert = 1 millires (*
1 milliroentgen)
J j
l i
l
t REGISTRY OF RADIOACTIVE, SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
~
NO.:
R-0487-D-101-S
_DATE: February 14, 1997 ATTACHMENT 3 Bedai Gauging Devied DEVICE TYPE:
bA Di A$I M b QjW //Y 2
b$$Wif/,Ae m
v.~ c 1A A
(I.$4
^
Q,,
_+
39 w~._ _
i
~~~
g una gar
' ~ ~...,
g@
N
<=L
,g -<g N
M' F!
t
+1 Lis D
t y
4 4
3
+
3 sc6 c-
- A- - -
A "
f@
-"}(
>-a p r pg g n
MOE}k
,a*
f A
7
.ae m,
q is p (.
19)
C b
,k f
e c<D a
5
. &'Q
,/
9 ;3 7
xu 7
x T
w
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-0487-D-101-S DATE: February 14, 1997 ATTACHMENT 4 DEVICE TYPEr Beta Gauging Device DySardsRh l
PART LIST, SOURCE HOLDER NSH-1 A4-1504 Nr Pcs Part Mfr Tvoe Ref.Nr. Material 1
1 Main Body Scienta 1484 Al (Elox) 2 2 Shutter Rail Scienat 1485A Al (Elox) 3 1 Shutter Slide Scienta 1485B Al (Elox) 4 1 Source Assembly Scienta 1487 Al (Elox) 5 1 Collimator Scienta 14888 Nylon 6 2 Lock Spring SB50x1,5 Steel 7
1 Source Capsule Amersham Kr85 or Am241 St. Steel.
8 1 Slide Block Scienta 1486A Al (Elox)
F 9
1 Cylinder Block Scienta 1486B Al (Elox)
I j
10 10 Screw M5x12 Stand. countersunk Steel I
11 28 Ball Bearing SKF 6 mm Steel l
12 4 Screw M4x5 Stand. slotted pan Steel 13 1 Pneumatic CylinderPimatic 12x70 stroke Steel 14 2 Locking Nut Scienta 1489 Brass 15 1
Indicator Pin Scienta 1490C Red Nylon 16 1 Cover Plate Scienta 1490A Al (Elox) 17 1 Cover Plate Scienta 1490B Al (Elor) 18 1 Contact Contact GmbH 20.1010AA+40.1002A1 19 4 Screw M2,5x5 Stand. slotted pan Steel 20 1 Profile Piece Scienta 1491A A1 (Elox) 21 1 Lid Scienta 1491B Al (Elox) 22 2 Distance Bolt M3x25 Hexagonal Brass 23 2 Screw M3x8 Stand. slotted pan Steel 24 2
IR transducer Data Logic RC-04S 25 1
Inductive Transd. Schmersal IFL 2-12M-10P 26 4 Distance Piece Scienta 1500 Al (Elox) 27 8 Screw M6x25 Stand. Umbraco St. Steel 28 1 Ring 68-52 Scienta 1488A Plastic 29 1 Lid Scienta 68mm 1488C A1 (Elox) 30 6 Screw M3x5 Stand. countersunk Steel 31 1 Diaphragm Etola 76um Teflon 32 1 Type Label Scienta 100x50mm Al 33 4 Screw M3x5 Stand. slotted pan Steel 34 1 Screen Plate Scienta 2mm Lead 35 2 Screw M3x5 Stand slotted pan Steel 36 1 Transport Lock Scienta 1505A Al (Elox) 37 1 Seal Ring 42,5x4mm Buna-N 38 4 Screw M5x5 Stand. Umbraco St. Steel
V h vo ~
G w skj o
y/ty?b
'hb M.',
Lp+
w
- i UK o 4 97D iols v&
W we
%%L, knLL.,
fM M5h otbM G w w hu3 b!%
' hC d%qQ e
%Jy9 ey?f hul $st by y
i 1
l i
i
-s__._A_
a w
a u
m
@.. t I
l I
U.S. Nw. AR REouLATORY COMMISSION [
pggg o,
PAars w
fl NRC Feem 374 A i
%I.' "
ucenu nernber 48-25892-01 I
i l? I el MATERIALS LICENSE I
g, I
eI SUPPLEMENTARY SHEET 030-30464 h
i I
f
.'I Amendment No. 01 g
l i
,I t
l Dyno Overlays, Inc.
I I
121 Vermont Avenue, S.
I, Hayward, WI 54843 (f
I In accordance with letter dated September 25, 1991 License Number 48-25897-01 is g
i i
i amended as follows:
p f
I I
f'2~
I j Item One (flame) is changed from: Noresin, Inc.
to: Dyno Overlays, Inc.
l l
Conditions 11. and 16. are amende h1 is? EG v l
Licensedmai.crialshallhphsedby,orunderthesupe iponof,JeffAikin, I
l 11.
l Len Costley or Pete M bul O
I
! 16. Except as specifica 1 p'rpvided otherwise in this license It> licensee shall l
5 conduct its prograrp, _ accord' e with the stateme
,,repres/ntations,and i
j n
ntinsures listed below.
I i
procedures contained /in the'Xfb
ts includino.a' l' govern MIess the statements, I
regu]etion
I The fluclear Regul/kry Commiss l
representations a procedur(s o e ifcinjee s lication agitt correspondence are l l more restrictive n the tjy1 t g.u..(
I Letters with entachWp' 't's dat,d44 r u n '.,'
1
.. FebruarrA. 1988, h )
I A.
t i r 1
8, July;,-14, 1., September 75, R
l 1991 and Decegr lik
,,19884 April 14, 198Y, Aprtg I
8>
f f t '.
-l. n * % r.m&' A
['.
s f
g
]
g Conditions 17. and 18. a addedf.
l
[
}
w, M/
s.
i 17.
In addition to the pos on limits 'tri Itd8, the licpde shall further restrict I
the possession of licens terial to quantities belgthe mininum limit specified l
in 10 CFR 30.35fd) for est ishtng decommission fisi3ncial assurance.
g The licensee shall maintain rec rds k k or ktion important to safe and effective 18.
I decommissionino at the address in Condition 10. per the provisions of I.
k I
10 CFR 30.35(g) until this license is terminated by the Commission, F
I k
I i
I i
I B
l i
i I
il
{
I f
sitao+310;Le 711223 (aff g
REG 3 LIC30 h
I MATLSLICENSING PDR For the U.S. Nuclear Reculatory Cerrnission I I
( lIl (1' E I
I
,,,j l,
W; By dh Qb l Date:
/I,<C 1 I
Mhterials Licensing Sectt6n, Region !!! Q i
i(XRi0ighyW0iFa0kMUssiX.41itiDifmTXJsw.marJr,riasiarma.ani!EWJurJJsichT&TamT 1LT&T.A
- _ - - -.. - - ~. -
i n.
i ;,
9 O
j Dyno Overlays, Inc.
Aoute 5 Son 8206 I
l December 11, 1991
,'[,$,",$'j7fg$
Ref.:
US-NRC.002 Phone ll5 634 5051 2
feiefaa 185 614 J161 United States Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention of Ms. Robert G. Gattone, Jr.
j Dear Roberts Ret Amendment Request of HRC License Number 48-25892-01 1
j With respect to your letter dated November 22,
- 1991, j
requesting further information relating to our amendmont request, we are submitting the following information:
i 1.
Chance 21 Ownershio I
i We feel that the ownership change of our parent j
i company does not constitute a change in ownership 1
or control of our NRC License 48-25892-01.
I have f
included in Attachment 1 a summary of out' existing a
structure.
)
2.
Detailed Determination Our new name is Dyno Overlays, Ir.c.
a.
j b.
Mark Lindquist who is listed as an authorized j
user is now working in a different position:
{
consequently, it is no longer practical to list i
him as an authorized user. Therefore, we would i
like to amend our authorized users' lia't on our j
license.
c.
We are still owned by our parent company and will continue to operate as we have in the past with respect to our NRC License, d.
Our parent company was previously owned 50% by Dyno Industrier of Norway and 50% by Kymmene/
Schauman Group of Finland. On January 1,1991, Dyno Industrier purchased the 50% share owned by Kymmene/Schaumans and on May 1,
- 1991, Noresin, Inc. changed its name to Dyno Overlays, Inc.
This name change doos not i
reflect a structural change in the E U M D of our company.
DEC 161991 REClON 111
i 6
\\
\\
O O
Page 2 US-NRC.002 12/11/91 i
i l
e.
There has been no change in organization, i
location, facilities, equipment, procedures, or j
personnel as a result of the remaining 50%
j purchase by Dyno Industrier of our parent company.
l f.
There has been no change in the use, j
possession, or storage of the licensed material.
g.
All records and surveillance items are i
currently up to date.
)
h.
Our facility is secure and has no j
contamination.
Please note that our two sources are Krypton-85 gas with an activity of i
200 millicuries each.
3.
buthorized Usera l
j As mentioned above we would like to add the following j
people to our license as authorized users l
Leonard.costley Peter Mayou Their training includes the followings They were both present at the time of installation a.
and received training from the manufacturors however, no documentation was received upon completion.
i j
b.
They have both received training on the following j
topics from Jeff Aikin, the plant engineer and 1
authorized usert i
l a) Safety Instructions For Radioactive Sources (see Attachment 2).
b)
Review of the operations manual for the
{
Scienta System IV measuring system.
c)
Review of "The Safety Arrangements of the Source Holder Used in Scienta Quality i
Control Systems" (see Attachment 3).
j d) A review of general safety procedures (see ).
l i
i i
c
^
i
\\,
O O
i US-NRC.002 Pago 3 l
12/11/91 i
Thank you for your time spent in reviewing our request.
If you require further information or have any questions, you may contact me at the above number or address.
l Best regards, Peter Kayou Environmental and safety Manager PMama Enclosures i
~
lly.j'!*^ f *
.a Dyno Overlays, Inc.
f
"*t'8805s206 ATTACl! MENT 1 121 Vermont Avenue South i
Hayward, Wluonun 5454 3 Phone 715 634 5057 Telefan 115 634 2361 1.
ADDRESS-(
121 Vermont Avenue South J
Route 8 Box 8206
)
!{ayward, Wisconsin 54843 1
2.
STAFF:
1 President & General Manager:
Randy E. Schwartthoff i
SS#:
475-56-7824 J
I Controller:
Chris R.
Klay SS#:
389-50-6993 I
3.
INCORPORATION:
Dyno Overlays, Inc., was incorporated on April 15, 1987, I
under the Wisconsin Business Incorporation Law.
The officers of this company are i
i Randy E.
Schwartzhoff, President Ralf Reinhard B6er, Secretary.
Mr. B6er is a partner with Foley & Lardner, Attorneys at Law, in Milwaukee.
Dyno Overlays, Inc., is wholly owned by the Finnish company, Dynoresin OY, which is 100% owned by the Norwegian company, Dyno Industrier A.S.
4.
PURPOSE:
Dyno overlays, Inc., has been organized for the purpose j
of building and operating a plant in !!ayward, Wisconsin.
Thir plant is designed for the production of phenolic resin impregnated overlay papers which are used as a coating for wood based boards sucn as plywood, waferboard, and particle board.
The plant may later be expanded to produce a wider range of impregnated papers.
l l
4 4
tet: Corp.001 l{
MMO Chemicals
l
~
3;% ~ e *;-
..e.
ATTACllMENT 2 f
SAFETY ItiSTRUCTIO!1S FOR RADIOACTIVE SOURCES i
Radioactive sources may only be handled by personnel 1.
having official authorizations.
1 For a person working in a radioactive hazardous area, the
{
maximum annual dose is 50 mSv (= 5 rem).
Thus, the 2.
average dose rate has to be less than 25 uSv/h in those (25 usv/h x 40 h x 50 weeks = 50.000 uSv/a = 50 f
areas mSv/a).
The nominal values for safely screened beta source used
)
3.
in basis weight meters are:
a) with open shutter at the edges of the safety i
plates:
less than 25 uSv/h (2,5 mrem /h) on a distance of 1 meter f rom the source with open b) or closed shutter:
less than 7,5 usv/h (0, 75 i
4 mrom/h) at the surface of the source holder with closed c) shutter in all directions:
less than 2 mSv/h (200 mrem /h).
Continuous exposure of human tissue is forbidden here.
At radiation hazard measurement the dose equivalent man 4.
unit Sievert (SV)
(- 100 rem) and the absorbed dose unit Older
( = 100 rad) can be kept as equivalents.
Gray (Gy) instruments may also be calibrated using Roentgen (R) units, which is defined as the expos'tred doue unit.
For radiation hazard purposes 1 rem = 1 rad = 1 R = 10 mSv, where rem rad and R are (not SI-normed) obsolete units.
CE004 April 1987 i
F:
h 9
9 Dyno Overlays, Inc.
3 Route 8 Box 8206 121 Vermont Avenue South Hayward, Wonun 5454 3 ATTACHMENT 4 Phone 715-634 5057 4
Telefan 715 634 236l
)
1 GENERAL SAFETY PROCEDURES FOR SCIENTA DEVISE
^
4 1.
Operators should stay six feet away from the scanner head.
'.f needed, when running controls on panel or
)
working around scanner head, the shutters can be closed.
Releasing the red button light will indicate the shutter is open.
When the shutter is open there is also a red rod on the scanner head that should be out.
When the j
shutter is closed the rod will not be visible and the i
green light will be on.
2.
Use safety glasses when cleaning or working around head and have the shutter closed.
3.
Talk to your supervisor if any problems occur or if you l
are unsure of the Scienta operations.
i j
1 t
DYNO Chemicals
=
l THE SAFETY ARRANGEMENTS OF Tile SOURCE !! OLDER USED IN
- l SCIENTA QUALITY CONTROL SYSTEMS i
l
- 1. The source capoule (7) is fitted in a piece of tube (4), which is mounted to a slide plate (3) moving along l
j rails (2) using standard steel balls as bearings.
l springloaded pneumatic cylinder (13) has its piston
- 2. A connected to the slide.
When pressurized the source l
assembly will move to a point in the center of the holder body where a hole with a thin teflon diaphragm admits the radiation to paso down to the receiver, the ion chamber.
i When the source capsule is in this working position a red l
plastic pin (15) is exposed through one of the side cover l
plates (16).
- 3. There is also an electric signal from an internal Inductive Transducer (25) which is available when the safety shutter is moving (even only slightly) from its standby (cafe) position. The signal indicates that the
)
i source is not completely safe and is used to illuminate remote set 9ty indicator lamps and gives alarm signal to i
the computer.
4.
The loadLng of the nourco holder is carried out through a lid (29) on the top of the main body, without of the holder. This work is dismantilng any other part allowed onoy by qualified poinnnnol. When loaded, one of the ucrown of the lid is sealed officially.
- 5. When the courco holder in transported, a small locking piece (36) is fitted over the red pin indicator hole on the cover plate (16). The piece keeps mechanically the safety shutter in its safe position. The locking lid has to be removed before use.
- 6. Two infrared position indicatore (24) are connected mechanically to the source holder. They have no influence on the oefety arrangement.
To the cource holder and to the receiver is normally 7.fitted two 500x500 mm screen plates made from 5 mm thick aluminum.
The distance between the opposite plates is normally less than 16 mm
(=
0,63 in) which makes it impossible to put human fingers in the primary radiation beam.
J l
1 I
l l
Dec 10.91 16:40 tio.019 P.08 l0 OVERLAYS. It4C TEL: 206-627-2896, 8
ATACllMENT 3 I
0 SantaWh 7
- 8. The beam in co111 mated and hao a diameter of 40 mm when leaving the cource holder through the diaphragm under working circumstances.
In the cafo position the
]
total absorbing wall thickness in 2 mm Iced and at least 5 mm aluminum, which is enough to minimize the radiation hazntd. The radiation measured around the courco holder is vainly scattered and emanaten from the metal pieces hit by the original primary field. A map chowing actual doce rates in different pointu, with the actual source fitted, 10 published for each case caparately.
1 9.Please observe that unsealed Krypton OS sources may not be transported as normal air cargo because of the low I
atmospheric pressure which might occur in the goods space of the aircraft.
Scjenta supplien special packing l
materials at requeot (precouro thight glass bottles).
i In such cases the source lo trannported separately in the i
gastight container and in then fitted in the sourco holder by qualified personnel at the oite where it in 4
permanently used.
i CE029
.MWf"
,a0
<wn
,;y g
s NOV 2 21991 Noresin, Inc.
l ATTN: Peter A. Mayou Environmental Safety Manager 121 Vermont Avenue, S.
Hayward, WI 54843
Dear Mr. Mayou:
We have reviewed your letter dated September 25, 1991 requesting amendment to NRC License Number 48-25892-01 and find that we will need additional information as follows:
l 1.
Change of Ownership It is necessary for you to review the enclosed Information Notice 89-25 regarding change of ownership. State the date the change of ownership is to take place, and respond to Items 2.a. through 2.h. of the Information Notice.
2.
Authorized Users i
In order to add Len Costley and Pete Mayou as authorized users on the license, you will need to submit documentation of their training and experience in gauge use.
Include the dates when training in the use and operation of the gauges was received and the instructor of the course.
If the training was given by the gauge manufacturer, submit the l
4 2
certificates documenting successful completion of the course.
If the training was not given by the manufacturer, submit an outline of the j
topics covered and the time spent on each subject.
We will continue our review of your application upon receipt of this j
i information. Please reply, in duplicate, within 10 days, and refer to Control Number 92341.
If you have any questions or require clarification on any of the information stated above, you may contact us at (708) 790-5625.
i Sincerely, Original Signed By i
Robert G. Gattone, Jr.
Materials Licensing Section
Enclosures:
1.
Information Notice 89-25 RIII T. D
~
Gattone/ms 11/?/91
.ye.
- n....
q q
Dyno Overlays, Inc.
R""88 ^8206 September 25, 1991 121 Vermont Avenue Svuth Ref.:
n,yw.,d, wie9 nun 54s41 Phone 115 634 5057 Telefan 715 634 2361 l
4 United States Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 Attention of Ms. Glenda Jackson
Dear Glenda:
l This letter is to inform you that Noresin, Inc. has changed its name to Dyno Overlays, Inc.
This change reflects the recent purchase by Dyno Industrier A.S of the remaining 50%
of Noresin.
Dyno Industrier, an international organization with headquarters in Oslo, Norway, now owns 100% of Noresin.
a We would like to take this opportunity to amend the following items on our material license:
I L :-.......d l..-...
l f. m.t.r.. N...
N..
?.
i 1.
Licensee Name l:.-.w.
2-From:
Noresin, Inc.
To:
Dyno Overlays, Inc.
' n:
.y p pp.
..: C:h ;s,r y...., ' '.
b! 70.
f 2.
Condition "11" rvcfF(3.
<. _ g /[..M.
i Omit:
Mark Lindquist
- c Chco e
'/.',,......
/
Add:
Len Costley I
i Add:
Pete Mayou 60 g.._...._..--.._.
3.
Radiation Safety Officer shall be Peter Mayou For your convenience I have included a copy of our Materials License. If you should have further questions, please feel free to contact me at the above address or phone number.
j i
l Very truly yours, 1./
/)])
/ ).& _ #f~~~-.----
kEgg[Ygg 3
Peter A. Mayou Enviro ental & Safety Manager SEP 2 7 bOI PAM:mm Enclosure i}
g E c to y,,,
.i 92341
@$ N.
i
)
Chemicals
,~
1 1
~
J d ' ENETW,WWIMMMErWErWWErmmmrpWW30sdt arasa isi 31W wasi,wwm ind is, wmwargan wg;Wunsas;3,w,p, p
h M NHFil Afl fil AHf ATHilt FAMWilllH W
H8 Wil l
,1 l
i I
i.-
blATERIACS LICENSE w
)
(
Puripint to the Atomic Energy Act of 1954, as amended, the Energy Reorganisation Act of 1974 (Puhhc l.aw 91 41R). and liite in.
p
! ode of federal Regulations. Chapter I. Parts 30. 31. 32,33,34,35. 40 and 70 and in reliance on statements and representanons i
s heretofore made by the licensee, a license is hereby hsued authorliing the licensee to recei,e. acquere, possess and teansfer b) product.
)
g
),
1 i
source and special nuclest material designated below; to use such material for the purpose (s) and at the plae c(s) drugnated below.to il l
1 deliver or transfer such material to persons authorlied to recelie it in accordance with the retulations of the appbrable Part(O This II i
license shall be deemed to contain the conditions speelned in Section IR) of the Atomic l'nergy Act of 1994, as amended, and n subject to all applicable rules, regulations and oiders of the Nuclear Regulatney Commission nom or hereafter m effect and to an) f q
4 conditions speelned below.
9, y
I
?
l' 9
48-25892-01 1
d 1.
Noresin, Inc.
3 (n ens, numae, i,
4 i
4 i
4 q
2.
121 Vermont Avenue, S.
l
~
Hayward. WI 54843 4 f%phanon da,e October 31,1993 g
i 4
5 Dos b ' "'
030-30464 Reference No i
4
]
4 6 th product. source. and/or 7 Chemkal and/or phpn al R klaumum amount that tnensee j
4 spect.i nuclear matraial inrm mm) possess at ans nne ome under this luense f
l4 A. Krypton-85 A. Sealed sources (Amersham A. No single source to 4
Model LAC.01) exceed 200 millicuries q
~
)
9.
Authorized Use To be used in OY Scienta Ab Model NSH-1 source holder for basis weight (thickness)
(.
A.
j measurement.
00HD1110NS 1
4 s
1 Licensed material shall be used only at the licensee's facilities located 4
10.
l at 121 Vermont Avenue South, llayward, Wisconsin.
- 11. Licensed material shall be used by, or under the supervision of, Mark A. 1.indquist or Jeff Atkin.
I l
12.
Sealed sources containing licensed mate 1.it shall not be opened or removed from k
the basis weight (thickness) gauges by the licensee, i
4 initial radiation survey, relocation, removal from service, maintenance Installation,
/
9 13.
and repair of devices containing sealed sources and installation, replacement, and disposal of sealed sources shall be performed only by persons specifically licensed j
by the Commission or an Agreement State to perform such services.
y
(
1 14.
The licensee shall conduct a physical inventory every 6 months to account for all i
I sources and/or devices received and possessed under the license.
Decords of 3
l inventories shall be maintained for 2 years from the date of each inventory, i
i 9
i n
1 4
9234L l
S gala.
l 1
w n.+. +.+...,, +,,,,.. +,,,..
E--"**Ac...uw..,
g..
e 1
a p.ac e-_ awe.=w+i. soup.ML'!.l.
Q.ll4 ' 5*
.ww =mus.easasww.ww 2
g
=p 2
pg l
Q su mb = = = = ==== = = U. S.
Lt AR REoVLATORY CoMMis$loM pg q
,, 'F e.In 3 F 4 A ptRC t.kenn nemter h
D'883 48-25892-01
}
M ATERI ALS 1.lCENSE I
I SUPPt.EMENT At1Y SilEET 010-30464 p'
F f,
The licensee shall assure that the devices are tested for proper operation p-of the on-off mechanism and indicator, If any, at interv I
15.
l I.
The licensee shall maintain records of the results of these tests f I
l These records period of one year after the next required test is performe
[
the name of the individual performing the test, 4
q Except es specifically provided otherwise in this license, the licensee shall q
conduct its program in accordance with the statements, representations, and l
16.
procedures contained in the documents including any enclosures, listed be l
The Nuclear Regulatory Comission's regulations shall govern unless the statem representations and procedures in the licensee's applicattun and currespond 4
4 more restrictive than the regulations.
l 16, 1988, february 76, 1988, April 14, tetters with attachments dated January
)
A.
14, 1988.
1988, April 27, 1988, July 8, 1988 and.luly 4
4 I
5 I
4 d'
4 4
4
(
d i
i e
i 1
4 l
i
/
4 te U.S. Nuclear Regulatniy Cnnsnistinn 4
9%
1 g$
s i
ks l
- [, Date
Dy,liile,kr iais licenu,q M *i E ng T,e__,t i _nn p e...,,,.111 c
ginn f
i en nAsm ur c.zerg +.+;.j;rcrycre.erzrc crir. rzre /. ;..,
., c..rers. ;r.e.. ;. c.... co. l e
<<NUDOCS/AD>>
TCON67 Nuclear Regulatory Commission Version 002.000
Records 1 5=== Subject / Field / Boolean Results = Select Count 5
Accession #
Docket Author Name Affil Issued Microfiche Address 9402170096 03030464 WATSON,G.
NE R3 940131 78167-228/78167-240
(*)
Matls licensing package for amend 2 to license 48-25892-01 for Dyno Overlays,Inc. Control:395837.
9201310166 03030464 GATTONE,R.G.
NE R3 911223 60462-215/60462-236
(*)
Matls licensing package for amend 1 to license 48-25892-01 for Dyno Overlays,Inc. Control:392341.
9110160003 03030464 LYNCH,J.L.
NE R3 910912 59361-002/59361-002
(*)
Safety insp on 910912 of license 48-25892-01.Insp findings:
records of gauge shutter checks not properly maintained.
8907110090 03030464 FINNE,E.
EMVNORES 880116 50420-105/50420-165
(*)
Application for license, authorizing importation & installation of QC sys on paper impregnating machine, supplied from OY 8907110072 03030464 MADERA,J.R.
NE R3 880928 50420-062/50420-165
(*)
License 48-25892-01 for Noresin,Inc, authorizing possession & use of 200 mci Kr-85 in OY Scienta Ab Model NSH-1 source holder for Arrows-Scroll, ENTER-Select, F10-Mark For Download, CTRL-F9-Continue Download.
Char Mode: Replace Page 1 Count:
- 5 DGl.nrc. gov 09:53:28 i
l
<<NUDOCS/AD>>
TCON67 Nuclear Regulatory Commission Version 002.000
Records 1 5=== Subject / Field / Boolean Results = Select Count 5
l l
Accession #
Docket Author Name Affil Issued Microfiche Address 9402170096 03030464 WATSON,G.
NE R3 940131 78167-228/78167-240 i
(*)
Matls licensing package for amend 2 to license 48-25892-01 for l
Dyno Overlays,Inc. Control:395837.
l j
l 9201310166 03030464 GATTONE,R.G.
NE R3 911223 60462-215/60462-236 i
l
(*)
Matla licensing package for amend 1 to license 48-25892-01 for l
Dyno Overlays,Inc. Control:392341.
l 9110160003 03030464 LYNCH,J.L.
NE R3 910912 59361-002/59361-002 l
(*)
Safety insp on 910912 of license 48-25892-01.Insp findings:
l records of gauge shutter checks not properly maintained.
8907110090 03030464 FINNE,E.
EMVNORES 880116 50420-105/50420-165
(*)
Application for license, authorizing importation & installation of QC sys on paper impregnating machine, supplied from OY 8907110072 03030464 MADERA,J.R.
NE R3 880928 50420-062/50420-165
(*)
License 48-25892-01 for Noresin,Inc, authorizing possession & use of 200 mci Kr-85 in OY Scienta Ab Model NSH-1 source holder for l
Arrows-Scroll, ENTER-Select, F10-Mark For Download, CTRL-F9-Continue Download.
Char Mode: Replace Page 1 Count:
- 5 Screen Dump Successful.
DGl.nrc. gov 09:53:28
<<NUDOCS/AD>>
TCON67 Nuclear Regulatory Commission Version 002.000
Records 1 5=== Subject / Field / Boolean Results = Select Count 5
Accession #
Docket Author Name Affil Issued Microfiche Address