ML20138L000
| ML20138L000 | |
| Person / Time | |
|---|---|
| Site: | (ISNM-01699, ISNM-1699) |
| Issue date: | 12/16/1985 |
| From: | Mccorkle G NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Hannett B TRANSNUCLEAR, INC. |
| References | |
| NUDOCS 8512190136 | |
| Download: ML20138L000 (9) | |
Text
_ _ _ _.
W
>%3 WD
%TT
@Q)P My d _L i2cau M b &'.
l
~
oEc28198s A
~
w f C u. s h / h, r e r o A P 1
m
[
9N 7
79720R
,im" Transnuclear, Inc.
j ATTN:
Ms. Barbara A. Hannett 4:t l
Traffic Coordinator When coprated tre ~ -
One Skyline Place
. - E T MM AS 5205 Leesburg Pike
/
f-f Falls Church, VA 22041 t- - M e N (inaerf, propeydassifichtion)
Gentlemen:
/
This is in reqard to your request for approval of a route to be used for transport of spent reactor fuel as contained in your letter of October 16, 1985.
The route requested in your letter is judged to meet the regulatory requirements in accordance with 10 CFR 73.37 for shipments under import license ISmi-1699 and is approved through December 31, 1986.
Arrangements with law enforcement agencies along the route as required by 10 CFR 73.37(a)(2) have been completed by the fiRC staff.
Data relating to these arrangements and a copy of the approved route are enclosed.
This information is to be incorporated into your shipment plans and provided to your carrier along with instructions regarding its use.
Please note the.t assuring highway safety is the responsibility of the licensee and carrier and our approval is not intended to provide relief in this regard.
During seasonal periods when inclement weather with accompanying hazardous road conditions can occur with short_ notice, the appropriate state police should be contacted with regard to road conditions before a shipnent commences.
r please note that the not,ification requirements of 10 CFR 73.37(f) and 73.72 for each,shipnenjt stT1F apply. When naking a notification to a governor or his designee,Jt should be very specific especially with regard to notifica-tion of series shipments. Written notification nust designate exactly how many individual shipments are to be included.
In the event the number of shipynts in a series is revised, the change notification should indicate that it is a revision of the original notification and an increase or decrease in the number of shipments.
In addition, the change notification should spec-ify that the information for any of the shipments in the revised series nay not be decontrolled until ten days after the arrival at the destination of the last shipment in that series.
8512190136 851216 PDR XPORT
- A
~ ~ ~ ~ ~. ~. ~. WM 1 W
..?___.__._____.____
..y,$2yg. yyygy gg - u~..:. -
"==> x.arno mm a = c.. e.to m.to............. p.u.u.3.w n.g p.g.g{
.... t.p, ;
~
..p om) inictrativo cal Cri:::inal saoctions.
gg 1..... g fg grg g g
,g, s2c roru m no,soi sacu o24o OFFICIAL RECORD COPY
- u.s. am an-4oo-m u n e x n.- w r v e n n w w.. m m._~.- ~ m _. n n n m - m u: - ~ x,
I k3On ~d fi@MidUI$i(($hUlT L~
5'aOno t.p r n n a n a m m :
gy-q qp u,..
m.
.,o, un i o,s. w.um t e.
DEC 161965 Should you require additional information or have questions concerning this matter, please contact Charles Hillnan of my staff at (301) 427-4220.
Sincerely, George 11. McCorkle, Chief Safeguards Reactor and Transportation t.icensing Branch Division of Safeguards, N'4SS
Enclosure:
As stated Portsmouth/Aiken 07002479720R DISTRIBUTION:
w/ enclosure w/o enclosure Docket File /70-2479 SGRT r/f Case File /70-2479 tNSS r/f Region II RFonner LCRouse DWeiss PDR (Sanitized)
CHillman RRentschler Route only:
SGagner, PA
.., 3, m.v,. ; c.-
-0 jact to When copratel frc7 r0LMHIS DS oc " M
,,.T Ag 3 _ n; wic - e w n couctions.
a
,, d.i 7
l dL-f,(inserJ_tpro pcfassificationl]
J
...........2%2....1...
. s 1....Y.........s
.......M..c Co..r.k..l.e...
.....)O. ^ '
~.' '
'~..'l.'
cuxwm).CH n cw R
schler G
'L v v m.
...S.
I..........
D.........
.12
/85
.. i RW r.
M V
r one) 12//.....85 12/
.........\\... 8 5 w:c roau m no<eoiwncu o24o OFFICIAL RECORD COPY
- u.s. co an-4ao.2u n->a n~ ~, n -,.,
_n,,,.n.c _....-.,,.an. w e,,,,~ n.n. n._ u n - - = _ _
SPENT FUEL ROUTE Portsmouth, Virginia to DOE Savannah River Plant, Aiken, South Carolina DEC 1985 t
t
ROAD TRANSPORTAT10N R0 lite ~
~
PORTSMOUTH, VA TO THE DOE SAVANNAH RIVER PLANT, AIKEN, SC Total Mileage 437 VIRGINIA 1.
05-58 west to 05-17*
1.5 miles 2.
US-17 south to 1-264*
1.0 miles 3.
1-264 west to 05-58*
3.5 miles 4.
US-58 west to I-95**
68.0 miles 5.
1-95 south to North Carolina 12.0 miles Subtotal 86.0 miles NORTH CAROLINA 6.
1-95 south to South Carolina 181.0 miles Subtotal 181.0 miles SOUTH CAROLINA 7.
1-95 south to US-301 102.0 miles 8.
US-301 west to SC-70***
27.0 miles 9.
SC-70 west to SC-64***
23.0 miles
- 10. SC-64 west to Savannah River Plant ***
,13.0 miles Subtotal 170.0 miles Grand Total 437.0 miles
- Access to or exit from Interstate or State Preferred Routes.
- State Preferred Route,. Department of Health. Commonwealth of Virginia -
letter January 12', 1984.
- State Preferred Route, South Carolina Department of Health and Environmental Cnntrol letter. January 12, 1984. gc EBS
V
- ~
r F000 AND FUEL STOPS' The businesses and locations listed below were identifled by the NRC route analysis teams as possible food and fuel stops.
All possible stops along the route are not listed. Only a few of the locations were visited by the NRC teans.
In order to be listed, food and fuel stops were required to be close to the route.
VIRGINIA 1.
City of Franklin. Multiple Food and Fuel Stops.
2.
City of Emporia. Multiple Food and Fuel Stops.
Truckstops of America.
Exit 176 approximately six miles south of the Virginia / North Carolina state line.
2.
Lakewood Truck Stop.
Exit 168 at intersection of I-95 and NC Route 903, nine miles south of the Virginia / North Carolina state line.
3.
The 301 Truck Stop. Fayetteville, NC.
Monitors Citizens Band Radir..
Union 76 Truck Stop.
1-95 mile marker (mm) 133, Clarendon County.
2.
Truckstops of America.
Exit 102, four miles north of Santee.
3.
Multiple Truck Stops, Santee.
1-95 mm 97, Orangeburg County.
4.
Multiple Truck Stops, Orangeburg Area. US-301.
2 DEC 1985-i e
0
,y
.---<m_r.,,,
ys.--+
-m.r--
-,~--+wr+
-ge, 4my-,-
- -,.w -*+-mws e
t-r er
--w-r-
VIRGINIA ENERGENCY PHONE NUMRFRS: Arsa Cod 5 (804).24 hr statewitte numbg: 1 800-5R2.R350
^ *
(Stat? poIIco.dispatcn; CHESAPEAKE PORTSMOUTH CP (804) 547 6161 FRANKLIN CP (804) 393.RRll EP (804) 562.R575 SUFFOLK
- NORFOLK,
() 934 3111 COURTLAND CP (834) 441 7121 or R04) 539 7431 5 (R04) 633 2100 sp Rot) 539 379R
.COMM:
MT, R MT, R MT MT. C CH 9/19 i
i CH 9 LEA:-
eNorfolk (Off route)
(E)ePortsmouth eChesapeake eSuffolk (a)eFranklin eCourtland
- 1 *2
- 3 l
- 4 l
l l
j' Portsmouth !
Chesapeake Suf fol k l
!sle of l
Southhampton l
E.!LES IN l
l l
Wright County l County
- l JURISOICTION 6
5 21 6
34 i
l I
I i
TOTAL-
- MILES, 0
6 11 32 38 72 p
ROA0 TRANSPORTATION ROUTE PORTSMOUTH, VA TO THE DOE SAVANNAH R!vER PLANT, AIKEN, SC o
LEA Response Center
- l. NIT Port Area on Terminal Blvd. (0.5 miles);
HP/SP' Highway Patrol / State Police
- 2. Teminal Rivd. east to 1 564 (1.0 miles);
5 Sheri f f
- 3. I-%4 west to US.58 (3.5 miles);
C P' City Police
+4. US-58 west to 1-95 (68.0 miles);
C' P -
County Police
- 5. I-95 South to NC line (12.0 miles),
e CB Radio Monitored (Rase)
CR Radio Monitored (Car) ho.
Channel Monitorert R
React Group MT -
Radiotelephone (Useable) tEt 1585 E.
Escort Required 3
O e
____._._._-_,m
, VIRGINIA / NORTH r.AROLINA
'EMEarJMCY PHONE NUMR(R$: Area Cada -(A04) VA Area Corte (919) NC. 24 'hnur Statewide Numhar: 1 800 662 79'56 EMPORIA' ROANOKE RAP!OS ROCKY MOUNT WILSON
~
@ ) 634 6502 FP T414TUCIl01 HP (919) 46 8144 F'TVT9)237-5294 CP (R04) 634.65n2 Af ter 5pm:(919) 536 2101 Af ter 5 pm:(919)133 3861 (Raleigh) 1 Cnen; g CH 19. R
[-] CH 9-dT, a CH 19 MT, g CH 9 (3 CH 19, R L
LEA:
CP. 5 HP HP HP VA NC ibleEmporta (aleRoanoke Rapids (Off Route) eRocky Mount (Off Route) eWilson (Off Route)
- 5 f
'6 l
l l
5 Greenville Northampton/ Halifax Nash Wilson
' MILES IN l
County.
l Counties
-l County l
County' g
l 28 25 g
17 JURISDICTION g
14 g
g
- tnTAt I
i I
i I
- MILES 72 R6 114 139 156
.s KEY ROAN TRANSPORTATION ROUTE. PORTSMOUTH, VA TO THE DOE SAVANNAH RIVER PLANT, AIKEN, SC
-o' LEA Response Center 4
US 58 west to 1 95;
-HP/SP Highway Patrol / State Police
- 5.
I.95 south to North Carolina (12.0 miles);
Sheriff
+6.
195 south to South Carolina (181 miles);
i CP City Police 1
C'P County Police C8 Radio Monitored (Base) -
CB Radio Monitored (Car)
Channel Monitored R
React Group MT Radiotelephone (Useable)
E Escort Required 4
l Otr 1985 l
6 e
n e
e t
9
i
. ~ -_-
NORTH C ROLINA/ SOUTH ChR0 LINA
+
. (MERGENCY PH04E.NUM4ERs: Arsa Cade.(919) NC I.
I il '.' -
~
24 Hour Statswide Number: 1 800 662 7956*
(
Area Code (803) SC SMITHFIELO FAYETTEVILLE LUMBERTON FLORENCE HP (919) 934 2186 HP (919) 486 1334 W~[9T978623133 HP (803) 662.'4302 l
Comm:
MT. 3 CH 19. R g i,H 19 Q g CH 9/19 LEA:
HP HP HP HP SC (ble Smithfield (c) eFayettev111e (d) etumberton (e)
(a) l l
l l
Il l
Johnston and Harnett
. l County l
County l
County
~l Cumberland Robeson Dillon MILES IM l
Counties JURISDICTION g
43 l
28 l
40 l
24 l.
ToTAt.
I I
I I
l
-ElLES 156 199 227 267 291 ROAD TRANSPORTATION ROUTE - PORTSMOUTH VA TO THE DOE SAVANNAH RIVER PLANT, AIKEN, SC'
'o LEA Response Center
. 6.
1-95 south to South Caro 11ta HP/SP,
Highway Patrol / State Police
. *7.
I.95 south to US-301 (102.0 alles);
5.
Sheriff l
CP C1ty Po11ce C'P County Police I
CB Radio Monitored (8ase)
C8 Radio Monitored (Car)
Channel Monttored
'R React Group MT
. Radiotelephone (Usable)
E Escort Required DEC. 1985 4
t
.--,rw.-
=r-
+
-e r-
,m v---
v-v-
--rr----%-
rmo
.. - -.. -. -. ~ ~ _. _..
.. - _. ~ _ _
l SOUTH CAROLINA v
j, EMERGENCY LEA FLORENCE SUMTER ORANGEBURG BARNWELL~
. TELEPHONE NUMBERS:
T1)(II57]T62-4302 W[507)775-5353
'HP(803J534-3409 W(503)259-1411 S (803)259 3083 BAM8URG W(EU3T534-3409 COMM:
MT g CH 19/9 3 Q LM y g CH 9/19/R MT' m CH 9,
C3 C3 C1 LEA:
HP HP HP HP W, S Savannah River Factitty e Sumter eBamburg (b) e Florence (c)
(d)
(off route)
(e)
(f) e Orangeburg (off route) e Rarnwell l
l l
l '8
- 9 l
l.
- 10 i
g g
l Orangeburg Sumter Clarendon Florence g CountyBamburg l Barnwell l.
MIIESIN I
County County County County County 0 l
JURISDICTION l
23 I
14 1
33 I
41 1
11 19 1
i l
l l
I TOTAL MILES 291 319 333 366 407 418 437 g
ROAD TRANSPORTATION ROUTE - PORTSMOUTH. VA TO THE DOE SAVANNAH RIVER PLANT. AIKEN, SC
/
o.
LEA Response Center 7.
1-95 south to US-301 (102 miles);
-MP/SP.
Highway Patrol / State Police
- 8.
US-301 west to SC-70 (27 miles);
5 -
Sheriff
- 9.
SC-70 west to SC-64 (28 miles); and CP.
City Police
- 10. SC-64 west to Savannah River facility (13 miles).
C'P
County Police g
C8 Radio Monitored (Base)
CS Radio Monitored (Car)
Channel Monitored Dtc 1985 4
e
- e E
e 3m e-
__yr,__,_.s_
-