ML20138J480

From kanterella
Jump to navigation Jump to search
Informs of Planned Shipment of Irradiated Fuel Rod Segments from Monticello Nuclear Generating Plant to GE in Pleasanton,Ca.Model 1600 Series Cask Will Be Transported by Tri State Motor Transit Co.Shipment Details Listed
ML20138J480
Person / Time
Site: 07000754
Issue date: 10/28/1985
From: Kirkland M
GENERAL ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
26018, 52445, NUDOCS 8512170532
Download: ML20138J480 (3)


Text

'

GENERAL h ELECTRIC FDR-%

NUCLEAR ENERGY BuslNEss OPERATIONS GENEML ELECTRIC COMPANY

  • 17s CURTNER AVENUE o SAN JOSE, CAUFORNlA 95125 h[ (

October 28, 1985 Page 1 of 3 70- 7 f9' 07000 7fd30 y 4

snvr RECEIVEQ S

Director, U. S. Nuclear Regulato NOV 81985 > 5 Commission, Region III C

d.S. NUCLEAR REGULATORY

\\

779 Roosevelt Road t

conss:ca Glen Ellyn, Illinois 60137 tgtjs 3

^/..

Attention: Director

~

1.

Subject:

Shipment of Irradiated Fuel Rod Segnents Gentlemen:

General Electric Company, Nuclear Energy Business Operations, is planning a shipment of irradiated fuel rod segments from Monticello Nuclear Generating Plant, Monticello, Minnesota to General Electric Company, Pleasanton, CA.

A General Electric Model 1600 Series Cask will be transported by Tri-State Motor Transit Company in complete accordance wi+'

Title 10, Code of Federal Regulations, Part 73.37.

General Electric will be shipping at Monticello, MN. on our License Number SNM-1270 to our Vallecitos Nuclear Center License No. SNM-960.

Our contact at Monticello Nuclear Generating Plant is Dan Wegener, Nuclear Engineer.

Shipment details are as follows:

'e

'd.

Quantity and Type of Fuel 65 B M a.) 8 Irradiated Fuel Rod Segments C

Y b.) Total Shipment

  • Activity - 6110 Curies

<3 -

e c.) Total Shipment Decay Heat - 17 Watts s-q3 d.) Total Shipment Weight U Plus Pu - 4,662.20 Grams N

"'i, 8512170532 851028 i;"

/? 9 PDR ADOCK 07000754

&'d C

PDR

GENERAL $ ELECTRIC Page 2 of 3 Rod Isotopics e.)

Fuel Current U

.U-235 Total i

Segment Enrichment Weight Weight PU Wt.

Number

% U-235 (Grans)

(Grams)

(Grams)

DTB2603 1.04 577 6.0 4.0 DTB2605 1.04 577 6.0 4.0 DTB2606 1.04 577 6.0 4.0 DTB2706 1.03 571 5.9 3.9 XZ01002 1.09 577 6.3 4.5 XZ01003 1.50 589 8.8 2.3 XZ00702 1.31 SP1 7.6 3.2 XZ00703 1.50 585 8.8

2.3 TOTALS

4,634 55.4 28.2 Cask Identification: GE Model 1600 USA /9044/B( )F S/N 1604 Cask Weight:

27,300 lbs The attached shipment schedule contains information the Nuclear Regulatory Commission classifies as Safeguards Information subject to 10 CFR 73.21 requirements. We request that the contents of the letter be handled and dispersed only on a need-to-know basis as unauthorized disclosure is subject to administrative and criminal sanctions.

The information regarding shipment schedules must be safeguarded for a minimum of ten (10) days after completion of the shipment.

~

\\

GENERAL $ ELECTRIC Page 3 of 3 You will be notified of actual completion date and time. We will keep you advised of any changes in the shipment schedule should they occur.

Very truly yours, f=*

M. W. Kirkland, Specialist Hazardous Materials Transportation M/C 512, Phone: (408)925-5703 MWK:jd File: MWD 85-71 7

cc: Nuclear Materials Safety & Safeguards /SGMT USNRC Washington, D.C.

. Mr. ' Charles HiQman!

s

'l Director U.S. Nuclear Regulatory Commission, Region IV 611 Ryan Plaza Dr., Suite 1000 Arlington, Texas 76012 Director U.S. Nuclear Regulatory Commission, Region V Office of Inspection & Enforcement 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596

'.'y s

e

\\

~

l'

_a 3

N 3

'l f