b May 7, 1997 p{
EA 96-355 Commonwealth Edison Company ATTN: Mr. J. H. Mueller Site Vice President 101 Shiloh Boulevard Zion, Illinois 60099 i
Gentlemen:
This will acknowledge receipt of your letter dated April 11, 1997 and your check for $100,000 in payment for the civil penalty proposed by NRC in a letter dated March 12, 1997.
We noted that in your response to each violation, a description is provided that addresses corrective steps that will be taken to avoid further violations.
Several of the items within these sections have not been included in Attachment B, which identifies actions committed to by the Commonwealth Edison Company. We presume that because you described these activities as corrective steps that will be taken, your staff considers their completion commitments.
If this characterization is not consistent with your understanding of the matter, please contact me at (301) 415-2741.
Your corrective actions will.be examined during future inspections.
Sincerely, OriginalSigacci Dy James Websrcas James Lieberman, Director Office of Enforcement Docket Nos.
50-295; 50-304 License Nos.
A. Beach, RIII Q1STRIBUTION:
/,
,I l
fa h[fbS EA File AhV PDR NUDOCS DE ON RA:III D:0E M k9 h
MSatorius ABBeach.
JLieNr' man b
d 05/(o/97