ML20138J285

From kanterella
Jump to navigation Jump to search
Advises That GE Class 1E Isolation Devices Used at Facility & Discussed During 851206 Telcon Are Potter-Brumfield Type Mdr Devices.Isolation Devices Identical to Devices Employed at Grand Gulf,River Bend & Limerick Plants
ML20138J285
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 12/13/1985
From: Corbin McNeil
Public Service Enterprise Group
To: Adensam E
Office of Nuclear Reactor Regulation
References
NUDOCS 8512170477
Download: ML20138J285 (2)


Text

e, u

Pubhc Service Electric and Gas Company C*rbin A. McNeill, Jr.

Public Service Electric and Gas Company P.O. Box 236. Hancocks Bridge. NJ 08038 609 339-4800

- %ce President -

Nuclear i

December 13, 1985 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission

'7920 Norfolk Avenue Bethesda, Maryland 20814 Attention:

Ms. Elinor Adensam, Director Project Directorate 3 Division of BWR Licensing

Dear Ms. Adensam:

ISOLATION DEVICES IIOPE CREEK GENERATING STATION DOCKET NO. 50-354~

As a result of the telephone conversation held on December 6, 1985 between representatives of Public Service Electric and Gas Company (PSE&G)_,.Bechtel, General Electric (GE) and the NRC concerning qualification of GE supplied Class lE isolation devices (relays, optical isolators) utilized at Hope Creek; PSE&G notes that the subject isolation devices are Potter-Brumfield type MDR devices.

These isolation devices are identical to those employed at the Grand Gulf, River-Bend and Limerick Nuclear Plants.

Sincerely,

\\

i 0

^

lM2170477851213M 050003S4 A

A PDR At.tt.

1 o

Director of Nuclear 2

12-13-85 Reactor Regulation C

D.H. Wagner USNRC Licensing Project Manager R.W.

Borchardt USNRC Senior Resident Inspector