ML20138J230

From kanterella
Jump to navigation Jump to search
Intervenor Exhibit I-CCANP-132,consisting of 810604 Minutes of Incident Review Committee 850601 Meeting Re Item 97 Concerning Verification of Shielding Analysis Calculations. Item Not Reportable Per 10CFR50.55(e) & Closed
ML20138J230
Person / Time
Site: South Texas  
Issue date: 08/07/1985
From: Powell M
HOUSTON LIGHTING & POWER CO.
To: Jacobi L
HOUSTON LIGHTING & POWER CO.
References
OL-I-CCANP-132, NUDOCS 8510290292
Download: ML20138J230 (4)


Text

_

l 53 4% fW Od -

f d C A A/ M, 3 l2.

I T 7{f$-

r

,e wm ME L_-.__.

._.n _, _

'65 OCT*iG N053 g

Ilotton > Lighting @* Power Company epp m ALintu sa ---

g Ol8Ib1'I3 FF ct MEMORANDUM Te L. R. Jacobi June 4. 1981 rem M. E. Powell ST-HL-19331 t

SFN: V-0533 Incident Feview Cemittee (IRC) Peeting Mieutes Centerning 5.6;rcr Verificatien of Shielding Analysis Calculattens (Item a97);

June 1. 1991 SOUTH TEus re0 JECT ELECTRIC CENERATING STATION REFERENCT:

(2)

(1

$T-HL-19152

) GM-89161 (BLR Memorandum)

I (3) ST-B R-Hl.-39327 The IRC recenvened to evaluate the Brown & Rcot (284) report concernieg verificaticn of shielding analysis calculatices.

reviewed by the IRC (reference 1) and this itt.9 was reported to the NRC-This item was p Region IV as being "cotentially reportable cursuant to 10CFR50.55(e) on May 8. 1981 The pur;ose of the June 1.1981 meeting was to deterefre if the subject item reets the criteria for reportability.

3 The IRC Chairran initiated the meeting by statirg that the BIR report cencerning this item (reference 3) concluded that this ites is not reportable and does not r.eet the criteria of 10CFR$0.55(e). The B&R recort is based on a review of applicable regulatcry decurentatten and industry standards, discussions with other A/E's. and internal B&R pro-

, e..

ceduren.

ptt? Eagineering and Heaith Physics stated that they wert in agreement with the B&R re;crt based en the folicwing conclusions:

's (1) BLR shielding calculations are classified and cerformed according to procedures whicn are consistent with 10CFR50 Appendix B. A*tSI 5tandards N45.2 and N18.2. and industry practices, e.g. design activities are decurented within a document centrol system in accordance with written proce-darts, the adecutcy of a calculation is reviewed and checked by individual (s) other than the originator, and minimure O

checking requirements are specifled.

(2) The industry dees not, in general, censider shf elding as safety related.

(3) Within the industry, shielding calculations are generally reviewed by a checker and approved by management.

(4) The fortheeming revision to ANSI Standard N18.2 indicates in Section 3.5.1.4-(1), that shielding for safety class eculprent or onsite personnel is classiffed as nen nuclear safety.

O m.

~ ~. _ - _

n pott IF).

O

.:.:. ' 2 97. 3 ' E

'; y,',A 81

( C ANr 13 P 1

1

  1. h e ,,.o s

+

i

,1

' ' ' ' ~

/

s s ** /

/

bs;f l,; f p+/

,4, L es 1

~ /,/^ t,/

oS

c i

,f 1

I L-

...: = _.

=

_ = - -.=- -

llouston Lighting & Power Company i

OFFICE MEMOR ANDtlM Te June 4.1981 ST-Ht-19331 SDt: V-0530 s,,%

P89e 2

(!? 1*CF253. Aprendiz 8.Section II states. *The design c:ntrol reasures shall provide for verifying or checking t'e adecuacy of design such as by the perfor:sance of j

design revie s by the use of alternate or sirplifted 4

/

calculatienal rethods... program. The verifying or check-i/

iro process shall be performed by individuals or groups ther than those who perform the original design...organt-

ation".

A551 N45.2. Section 4.3. retterates 10CFRSO and

covides additicnal direction as to trecific verification er checking procedures i.e.
  • verifying or checking should censist of a minimum...resiewing Fe design spot checking t'e calculations or analyses, and assessing the results against tFt original design bases and functicn require-tw9ts....*

B1R shielding calculations are checked and etertved by t' o engineers other than the originator, i.e.

a checker and the Olscipline Project Engineer (Dpt).

The c't:Ler reviews the calculation for such thirgs as meth-edelegy. assu ptions. Input, references, rathematics.

a: licability of cedes and standards, and results.

The calculaticn is then reviewed and accreved by the CPE.

In a:dition to these precedures, addittenal internal crocet

e. ts have teen 1 ple e9ted that include a sirpitfied
  • t.ar.d calculation by the checker".

In ad!'t*:n Ht1P Eagineering stated that B1R uses the terninology " design verificat :9" i

in conjunction with these items that are classified as being safety t'ated and that B1R perfer-s the same level of review for a shield.

irg cak.'stien that ene would perf:rm for a ' design verified

  • calc l ti bcsese. t$e shielding calculaticn is not designated as being safety related.

ua on; The !*: c: cluded that 214 has thosn that a "several tie'r' review ts per-formed f:r stielding calculations ard that they are in fact

  • verified" to be c:r e:t s'thcugh the calculatiens are not labeled as being " design ve ri f'e:',

The IRC determined that this item does not r tet the criteria for re::-tatility per 10C'R50.55(e) and, therefore is not reportable.

itts is m sidered to be closed.

This MEP/ par r

i mtt no.

i 0 0 2 94.35 6 ooossa

5-7

}

\\

i

),

{

9

~

llouston Lighting & Power Company OFFICE Minl0R ANDU4 Th June 4, 1981 5T-HL-19331 5FN: V-0530 j

Page 3 l

ATTENDEES:

M. E. Powell J. G. White R. R. Hemander J. L. Blau J. B. Anderson J. D. McAlpin cc:

J. H. Goldcerg D. G. Barker C. G. Rebertsom R. A. Fra2ar J. W. Briskin J. R. Septer G. L. Parkey H. G. Overstreet T. J. Jordan 3

H. J. Sweeney 3

R. L. Waldrop K. R. Cook (B14)

J. L. Fa ks (B&R)

H. McGee (614)

J. D'01tver (314)

J. R. Childers (SSR)

P. 5. Jorden (B&R)

]

STP RMS B&R CCC STP Engineering File 3@.

( _ _ _

R0tt NO.

O (Y 2.'_9: 3T 7:

00055A

z. _