ML20138C152

From kanterella
Jump to navigation Jump to search
Provides Westinghouse Responses to NRC Requests for Addl Info Pertaining to AP600 in-vessel Retention of Molten Core Debris Topic
Date released: 05/31/2020 Download: ML20138C152


Review of Rept DOE/ID-10541:Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C479
Person / Time
Site: 05200003
Issue date: 09/20/1996
From: Jacobs H
GERMANY, FEDERAL REPUBLIC OF
To:
References
Download: ML20138C479 (7)
Review of Rept DOE/ID-10541:Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C464
Person / Time
Site: 05200003
Issue date: 11/20/1996
From: Jacobs H
GERMANY, FEDERAL REPUBLIC OF
To:
References
Download: ML20138C464 (9)
Review of DOE/ID-10541 & Supporting Documentation.
ML20138C419
Person / Time
Site: 05200003
Issue date: 08/23/1996
From: Bankoff S
NORTHWESTERN UNIV., EVANSTON, IL
To:
References
Download: ML20138C419 (6)
Review of Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C406
Person / Time
Site: 05200003
Issue date: 09/26/1996
From: Matt Young
SANDIA NATIONAL LABORATORIES
To:
References
Download: ML20138C406 (6)
Premixing of Steam Explosions:PM-ALPHA Verification Studies.
ML20138C397
Person / Time
Site: 05200003
Issue date: 11/29/1996
From: Turland B
UNITED KINGDOM
To:
References
Download: ML20138C397 (7)
Review of DOE/ID-10541:Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C379
Person / Time
Site: 05200003
Issue date: 10/30/1996
From: Turland B
UNITED KINGDOM
To:
References
Download: ML20138C379 (9)
Review on Rept DOE/ID-10541, Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C346
Person / Time
Site: 05200003
Issue date: 11/20/1996
From: Mayinger F
TECHNISCHE UNIVERSITAT MUNCHEN (TECHNICAL UNIVERSITY
To:
References
Download: ML20138C346 (7)
Comments About Document Lower Head Integrity Under in Vessel Steam Explosion Loads.
ML20138C220
Person / Time
Site: 05200003
Issue date: 03/12/1996
From: Berthoud G
FRANCE
To:
References
Download: ML20138C220 (7)
Review of DOE/ID-10541, Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C210
Person / Time
Site: 05200003
Issue date: 11/18/1996
From: Fletcher D
AUSTRALIA, GOVT. OF
To:
References
Download: ML20138C210 (11)
Review of DOE/ID-10541, Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C193
Person / Time
Site: 05200003
Issue date: 01/08/1997
From: Butler T
LOS ALAMOS NATIONAL LABORATORY
To:
References
Download: ML20138C193 (6)
Lower Head Integrity Under In-Vessel Steam Explosion Loads.
ML20138C177
Person / Time
Site: 05200003
Issue date: 06/30/1996
From: Maureen Burger
GERMANY, FEDERAL REPUBLIC OF
To:
References
Download: ML20138C177 (35)
Provides Westinghouse Responses to NRC Requests for Addl Info Pertaining to AP600 in-vessel Retention of Molten Core Debris Topic
ML20138C146
Person / Time
Site: 05200003
Issue date: 04/15/1997
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: QUAY T R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20138C146 (52)